Instrumentation · Engineering · Package · PLC
0755-82221901 sales@ainstru.com

6I5B Thermal mass flowmeter

6I5B Thermal mass flowmeter
Thermal mass flowmeter
Configurable Models 4 models
Insertion flowmeter with high long-term stability, remote version design, up to 4 inputs/outputs
Compare

Measurement

Measuring principle Thermal mass flow (insertion type)
Measured variables Mass flow, temperature, corrected volume flow, volume flow, flow velocity, heat flow, energy flow, density
Accuracy ±1.0 % o.r. (100…10 % range); ±0.10 % o.f.s. (10…1 % range)
Repeatability ±0.25 % o.r. at flow velocity >1.0 m/s
Response time Typically < 3 s (63 % step response, bidirectional)

Process conditions

Max. process pressure 20 bar (290 psi)
Ambient temperature -40 … +60 °C (-40 … +140 °F)
Storage temperature -50 … +80 °C (-58 … +176 °F)
Process connection Insertion type, DN 80…1500 (3…60")

Electrical & communication

Protection rating IP66/67, Type 4X (optionally IP68 Type 6P)

Certification

SIL certification SIL 2

Spare Parts & Accessories 39

39 spare parts · click to collapse
Order codeDescription
XPD0052-ISEM electronics insert, t-mass 300/500Usage: t-mass 300/500 digital. Valid for approvals acc. feature 010. ISEM module V305-02.Enquire
XPD0054-ISEM electronics module, t-mass 500Usage: t-mass 500 digital. Valid for approvals acc. feature 010. ISEM module V305-00.Enquire
XPD0037-I/O moduleUsage: Proline 300/500Enquire
XPD0038-I/O moduleUsage: Proline 300/500Enquire
XPD0031-Display moduleUsage: Proline 300/500, DKX001.Enquire
71323009Power supply assemblyUsage: Promag/Promass/Prosonic Flow/ t-mass/Teqwave MW 300/500 digital, Non-haz, Zone 2, transmitter housing, electronic compartment.Details
71323012Main electronics connection board assembly, explosion-proof, Promass 500 digitalUsage: Promass/t-mass 500 digital, transmitter housing, electronic compartment.Details
71323013Main electronics connection board assembly, non-explosion-proof, 500 digitalUsage: Promag/Promass/Prosonic Flow/ t-mass/Teqwave MW 500 digital, transmitter housing, electronic compartment.Details
71323015ISEM Connection Board Assembly, Explosion-proof, 500 DigitalUsage: Promag/Promass/t-mass/ Teqwave MW 500 digital, sensor connection housing.Details
71185788T-DAT moduleDetails
71323006ribbon cable assemblyUsage: Promag/Promass/t-mass/ Teqwave MW 500 digital, sensor connection housing.Details
71323077Terminal Block AssemblyUsage: transmitter housing Alu/polycarbonate, connection compartment. Option A = HART, PROFIBUS PA, FOUNDATION Fieldbus, Profinet APL, Modbus TCP APL. Consists of: 1x connection terminal 2-Pol., 1x connection terminal 3-Pol., 1x connection terminal 4-Pol., 1x connection terminal 6-Pol.Details
71327820Terminal Block AssemblyUsage: transmitter housing Alu/polycarbonate, connection compartment. Option C = PROFIBUS DP, Modbus RS485. Consists of: 1x connection terminal 2-Pol., 1x connection terminal 3-Pol., 1x connection terminal 4-Pol., 1x connection terminal 6-Pol.Details
71384170Promag400/500 coverUsage: Prosonic Flow 400, Promag 400(C), (C) = generation index C, Promag/Promass/Prosonic Flow/t-mass/ Teqwave MW 500 digital, transmitter housing Alu. Consists of: cover Alu complete included O-Ring 196,40x3,53 VMQ, default and -50oC/-58oF, wire with screw lock 1,5x150.Details
71408508housing coverUsage: Promag/Prosonic Flow 400, Promag/Promass/Prosonic Flow/t-mass/ Teqwave MW 500 digital, Promag 800(C), (C) = generation index C, transmitter housing polycarbonate. Consists of: cover polycarbonate complete, O-Ring 196,44x3,53 VMQ, default and -50oC/-58oF, wire with screw lock 1,5x150.Details
71278078cover seal ringUsage: Prosonic Flow 400, Promag 400(C), (C) = generation index C, Promag/Promass/Prosonic Flow/t-mass/ Teqwave MW 500 digital, transmitter housing Alu. Consists of: 10x O-Ring 196,40x3,53 VMQ, default and -50oC/-58oF.Details
71278077Polycarbonate cover gasketUsage: Prosonic Flow 400, Promag/Promass/Prosonic Flow/t-mass/ Teqwave MW 500 digital, Promag 400/800(C), (C) = generation index C, transmitter housing polycarbonate. Consists of: 10x O-Ring 196,44x3,53 VMQ.Details
71228796Cover assemblyUsage: Promag 10/500, Promass 500, Promag/Promass/Prosonic Flow/t-mass/ Teqwave MW 500 digital, Promag 400/800(C), (C) = generation index C, sensor connection housing. Consists of: cover Alu, O-Ring 113,90x3,53 HNBR.Details
71323050Cover AssemblyUsage: Promass 500, Promass/Prosonic Flow/t-mass 500digital, sensor connection housing. Consists of: cover Alu, O-Ring 113,90x3,53 FVMQ, -50oC/-58oF.Details
71323051Housing seal kitUsage: Promass 500, Promass/Prosonic Flow/t-mass/ Teqwave MW 500 digital. Sensor connection housing. Consists of: O-Ring 113,90x3,53 HNBR for cover, gasket HNBR for housing/sensor.Details

Configurator / Comparison

ConfigureEnter a product model to configure
CompareEnter the product models to compare — up to three products
4 models · click to collapse
tmass i500(65 条)→

数据摘自 Endress+Hauser 操作手册,含状态信号、可能原因与维修指导。

Municipal Wastewater Treatment

Municipal Wastewater Treatment · Thermal Gas Mass Flow Meters — Application Case

Customer Profile

The typical setting in Municipal Wastewater Treatment is the inlet, biological and outlet stages of a municipal plant. The measuring point is Thermal Gas Mass Flow Meters; the focus is mass flow of air and fuel gases.

Key Difficulties

Conditions are high solids and corrosive fractions, with large diurnal flow swings and, on top of that, effluent parameters drift and probes foul with sludge and biofilm, which a standard configuration cannot handle for long. The design therefore starts with choosing insertion or in-line type by gas composition, temperature and dust.

Implementation

The scope ran through the flow range: flow solution matched to line size, medium and range. Technically it hinges on choosing insertion or in-line type by gas composition, temperature and dust, and on these requirements: stable compliance with Grade 1A discharge limits and online data reporting.

Customer Benefit

In practice this means direct mass output, making combustion ratios more precise, which cut the workload on the site maintenance team.

Food & Beverage

Food & Beverage · Thermal Gas Mass Flow Meters — Application Case

Project Background

The project covers dosing, pasteurising, filling and CIP stages. The work centres on Thermal Gas Mass Flow Meters and the core task is mass flow of air and fuel gases.

Operating Challenges

The medium and duty are characterised by syrups, dairy and beverages that scale easily, under strict hygienic requirements, and frequent cleaning demands instruments that withstand hot CIP/SIP caustic cycles. So Thermal Gas Mass Flow Meters cannot be specified generically — it calls for choosing insertion or in-line type by gas composition, temperature and dust.

Solution

The Ainstru engineering team worked through the flow range: flow solution matched to line size, medium and range. The configuration involves choosing insertion or in-line type by gas composition, temperature and dust, with these requirements in view: food-safety and hygienic design per 3-A / EHEDG.

Results

Since start-up the system has run steadily; the practical result is direct mass output, making combustion ratios more precise.

Chemical & Pharmaceutical

Chemical & Pharmaceutical · Thermal Gas Mass Flow Meters — Application Case

Project Overview

The site is reactors, metering vessels and finished-product tanks. The customer wanted Thermal Gas Mass Flow Meters properly configured on the existing plant, with the aim of mass flow of air and fuel gases.

Technical Challenges

What actually causes trouble is highly corrosive media with solvents and crystallisation, partly in explosive atmospheres, and corrosion plus Ex protection shortens instrument life and makes downtime costly. All of this means the Thermal Gas Mass Flow Meters configuration has to involve choosing insertion or in-line type by gas composition, temperature and dust.

Configuration

Supply and installation were organised through the flow range: flow solution matched to line size, medium and range. On site this meant choosing insertion or in-line type by gas composition, temperature and dust, checked line by line against: Ex certification and GMP traceability of records.

Performance

After commissioning the outcome is direct mass output, making combustion ratios more precise, and the readings are now used for process tuning.

Power & Energy

Power & Energy · Thermal Gas Mass Flow Meters — Application Case

Site Conditions

This is a Power & Energy customer whose plant is at boiler feedwater, turbine condensate and FGD/DeNOx systems. The main task was mass flow of air and fuel gases.

The Problem

The difficulty lies in high temperature and pressure with both steam and saline water; at the same time drift under high temperature and pressure, with very costly unplanned outages. Specification therefore means choosing insertion or in-line type by gas composition, temperature and dust.

What We Did

We took a flow range approach — flow solution matched to line size, medium and range. Delivery was built around choosing insertion or in-line type by gas composition, temperature and dust, with point-by-point checks on: compliance with power-industry codes and unit availability targets.

Operating Outcome

In service the system performs as intended — direct mass output, making combustion ratios more precise, with routine maintenance falling noticeably.