Instrumentation · Engineering · Package · PLC
0755-82221901 sales@ainstru.com

DTT35 Flowphant T

DTT35 Flowphant T
Flowphant T DTT35
Configurable Models 20 models
The switch is designed for the safe monitoring and display of relative mass flow rates of liquid media in hygienic applications, for example the monitoring of cooling water circulation systems and filter monitoring in the beverage industry. It can be selected between one or two switch outputs as well as one switch output and one standardized analog output for flow rates or temperature values. A variety of hygienic process connections leads to a flexible use.
Compare

Liquids

Measuring Principle Thermal
Product headline Flow switch for hygenic liquid applications, intelligent / programmable; insertion style
Nominal diameter range DN 25...1000
Max. measurement error 2% - 10% (per measurement range)
Measuring range 1"...40"
Max. process pressure 100 bar (1.740 psi)
Medium temperature range -20...+85°C
(-4...+185°F)
CIP able to 130°C / 266°F
Degree of protection IP 66
Display/Operation LED
LCD-Display
Outputs 1 x PNP switchable output + 1 x 4...20 mA analog output

Product Overview

This flow switch is specially designed for the safe monitoring and display of liquid mass flow in hygienic processes in the beverage industry, for example monitoring cooling water circulation systems and filtration. It offers 1 or 2 switch outputs, or 1 switch output and 1 standard analog output for outputting flow and temperature values. It is highly flexible and suitable for a wide range of hygienic process connections.

  • Advantages

  • Negligible pressure loss

  • FieldCare configuration software for fast setup and reliable storage of setpoints

  • Selectable 4 to 20mA analog output for reading the flow percentage value

  • Optional second switch output or 4 to 20mA analog output for temperature monitoring

  • Digital display panel for online function check and process information display

  • The housing top can be rotated 310°, equipped with a rotatable display panel for reading measured values from any direction

  • 3-A approval

Spare Parts & Accessories 4

4 spare parts · click to collapse
Order codeDescription
71535693M12 elbow plug ready for cable, IP67, PG7Details
510051485 m cable, 4x0.34 mm², PVC5米线缆,4x0.34m㎡,PVC M12x1 拐角航空插头, 螺栓 Cu Sn/NI,IP67Details
71535688Gasket rubber cap CDI-connectorPacking unit: 5 piecesDetails
TXU10-Instrument Commissioning Kit TXU10用于可以PC编程调试的设备 程序设置+用于带USB接口的PC的连接线Enquire

Configurator / Comparison

ConfigureEnter a product model to configure
CompareEnter the product models to compare — up to three products

Source:Endress+Hauserwebsite public information

83 models · click to collapse
All documents for this model
10 documents · click to expand
BA

BA Flowphant T DTT31, Flowphant T DTT35 Chinese

Rev. 1925 44 pages
Preview
BA

BA Flowphant T DTT31, Flowphant T DTT35 English

Rev. 1925 52 pages
Preview
BA

Operating Instructions Flow switch Flowphant T DTT31, DTT35 English

Rev. 1310 36 pages
Preview
BA

ReadWin® Quick Setup English

15 pages
Preview
BA

Operating Instructions Flow switch Flowphant T DTT31, DTT35 English

28 pages
Preview
TI

TI 焊接接头、过程转接头和法兰 Chinese

Rev. 2726 130 pages
Preview
TI

Flowphant T DTT31, DTT35 Chinese

Rev. 0420 24 pages
Preview
TI

TI Weld-in adapter, process adapter and flanges English

Rev. 2726 132 pages
Preview
TI

TI Flowphant T DTT31, Flowphant T DTT35 Flow switch English

Rev. 0525 24 pages
Preview
TI

Flowphant T DTT31, DTT35 Technical Information English

Rev. 0111 20 pages
Preview
Municipal Wastewater Treatment

Municipal Wastewater Treatment · Thermal Gas Mass Flow Meters — Application Case

Customer Profile

The typical setting in Municipal Wastewater Treatment is the inlet, biological and outlet stages of a municipal plant. The measuring point is Thermal Gas Mass Flow Meters; the focus is mass flow of air and fuel gases.

Key Difficulties

Conditions are high solids and corrosive fractions, with large diurnal flow swings and, on top of that, effluent parameters drift and probes foul with sludge and biofilm, which a standard configuration cannot handle for long. The design therefore starts with choosing insertion or in-line type by gas composition, temperature and dust.

Implementation

The scope ran through the flow range: flow solution matched to line size, medium and range. Technically it hinges on choosing insertion or in-line type by gas composition, temperature and dust, and on these requirements: stable compliance with Grade 1A discharge limits and online data reporting.

Customer Benefit

In practice this means direct mass output, making combustion ratios more precise, which cut the workload on the site maintenance team.

Food & Beverage

Food & Beverage · Thermal Gas Mass Flow Meters — Application Case

Project Background

The project covers dosing, pasteurising, filling and CIP stages. The work centres on Thermal Gas Mass Flow Meters and the core task is mass flow of air and fuel gases.

Operating Challenges

The medium and duty are characterised by syrups, dairy and beverages that scale easily, under strict hygienic requirements, and frequent cleaning demands instruments that withstand hot CIP/SIP caustic cycles. So Thermal Gas Mass Flow Meters cannot be specified generically — it calls for choosing insertion or in-line type by gas composition, temperature and dust.

Solution

The Ainstru engineering team worked through the flow range: flow solution matched to line size, medium and range. The configuration involves choosing insertion or in-line type by gas composition, temperature and dust, with these requirements in view: food-safety and hygienic design per 3-A / EHEDG.

Results

Since start-up the system has run steadily; the practical result is direct mass output, making combustion ratios more precise.

Chemical & Pharmaceutical

Chemical & Pharmaceutical · Thermal Gas Mass Flow Meters — Application Case

Project Overview

The site is reactors, metering vessels and finished-product tanks. The customer wanted Thermal Gas Mass Flow Meters properly configured on the existing plant, with the aim of mass flow of air and fuel gases.

Technical Challenges

What actually causes trouble is highly corrosive media with solvents and crystallisation, partly in explosive atmospheres, and corrosion plus Ex protection shortens instrument life and makes downtime costly. All of this means the Thermal Gas Mass Flow Meters configuration has to involve choosing insertion or in-line type by gas composition, temperature and dust.

Configuration

Supply and installation were organised through the flow range: flow solution matched to line size, medium and range. On site this meant choosing insertion or in-line type by gas composition, temperature and dust, checked line by line against: Ex certification and GMP traceability of records.

Performance

After commissioning the outcome is direct mass output, making combustion ratios more precise, and the readings are now used for process tuning.

Power & Energy

Power & Energy · Thermal Gas Mass Flow Meters — Application Case

Site Conditions

This is a Power & Energy customer whose plant is at boiler feedwater, turbine condensate and FGD/DeNOx systems. The main task was mass flow of air and fuel gases.

The Problem

The difficulty lies in high temperature and pressure with both steam and saline water; at the same time drift under high temperature and pressure, with very costly unplanned outages. Specification therefore means choosing insertion or in-line type by gas composition, temperature and dust.

What We Did

We took a flow range approach — flow solution matched to line size, medium and range. Delivery was built around choosing insertion or in-line type by gas composition, temperature and dust, with point-by-point checks on: compliance with power-industry codes and unit availability targets.

Operating Outcome

In service the system performs as intended — direct mass output, making combustion ratios more precise, with routine maintenance falling noticeably.