Instrumentation · Engineering · Package · PLC
0755-82221901 sales@ainstru.com
65F
Thermal mass flowmeter
Configurable Models 6 models
The t-mass 65F inline device is specially designed for the direct mass flow measurement of industrial gases and compressed air. With a turndown of typically 100:1 it can measure accurately operational flow rates and off line leakage. The integrated gas engine allows the customer to configure the device for 20 freely selectable gases.
Compare

Gas

Measuring Principle Thermal
Product headline std_productprofile_product_usp_12695.
std_productprofile_product_field_of_application_12696.
Sensor features std_productprofile_product_benefits_12697. Cost-effective measurement – easy installation, negligible pressure loss and maintenance-free.
std_successorproducts_product_differentiating_tech_features_50120_1545318798. std_successorproducts_product_differentiating_tech_features_50121_1545318798. std_successorproducts_product_differentiating_tech_features_50122_1545318820.
Transmitter features Reliable flow trending – multivariable measurement. std_productprofile_product_benefits_12703. std_productprofile_product_benefits_12704.
std_successorproducts_product_differentiating_tech_features_50123_1545318798. std_successorproducts_product_differentiating_tech_features_50124_1545318798. std_successorproducts_product_differentiating_tech_features_50125_1545318798.
Nominal diameter range DN 15 to 100 (1/2" to 4")
Wetted materials Transducer: 1.4404 (316L); Alloy C22, 2.4602 (UNS N06022)
Process connections: 1.4404 (316L/316)
Sensor body:
DN 15 to 25 (1/2"" to 1""): CF3M-A351
DN 40 to 100 (1-1/2"" to 4""): 1.4404 (316/316L)
Bushing: PEEK GF30, PVDF
O-ring seals: EPDM, Kalrez 6375, Viton FKM
Measured variables Mass flow, temperature, volume flow, energy flow
Max. measurement error Gas: 1.5% o.r. (10 to 100% o.f.s.), 0.15% o.f.s. (1 to 10% o.f.s.)
Measuring range 0.5 to 3750 kg/h (1.1 to 8250 lb/h)
Max. process pressure PN40 / Cl. 300 / 20K
Medium temperature range -40 °C to +100 °C (-40 °F to +212 °F)
Ambient temperature range -20 °C to +60 °C (-4 °F to +140 °F)
Optional: -40 °C to +60 °C (-40 °F to +140 °F)
Transmitter housing material Transmitter housing:
Compact: powder coated die-cast aluminium
Wall-mount: powder coated die-cast aluminium
Remote field: powder coated die-cast aluminium
Connection housing (remote version): powder coated die-cast aluminium
Degree of protection IP 67
NEMA 4x
Display/Operation Liquid crystal: back-lit, two lines with 16 characters per line
Configuration via local display and operating tools possible
Outputs 4-20mA HART (active/passive selectable), pulse, frequency, status
Inputs 4-20mA, status input
Digital communication HART, PROFIBUS DP, PROFIBUS PA, FOUNDATION Fieldbus, Modbus RS485
Power supply 85 to 260 VAC, 45 to 65 Hz
20 to 55 VAC, 45 to 65 Hz
16 to 62 VDC
Hazardous area approvals ATEX, FM, CSA, NEPSI
Product safety CE, C-tick, EAC marking
Pressure approvals and certificates PED, CRN
Hygienic approvals and certificates Oxygen service (certified acc. To BS IEC 60877)

The built-in device is specially designed for the direct mass flow measurement of industrial gases and compressed air. By turning down the typical turndown ratio of 100:1, operating flow rates and offline leakage can be measured accurately. The built-in gas engine allows users to configure the device and freely select from 20 gases for measurement.

  • Advantages

  • Can measure gases and gas mixtures in small pipes

  • High performance—high accuracy and repeatability, wide range of applications, measures utility and process gases

  • Economical measurement—easy installation, negligible pressure loss, no calibration required

  • Reliable flow measurement - multivariable measurement

  • Fast and effective commissioning: with operating instructions

  • High device availability: self-diagnostics and error monitoring

  • Automatic recovery of service data

  • Areas of application

  • For measuring the mass flow of various gas types, for example:

  • Compressed air flow

  • Natural gas flow in boilers/dryers

  • Carbon dioxide flow in breweries

  • Biogas and aeration in sewage plants

  • Gas products (e.g. Ar, N2, CO2, He, O2)

  • Leak detection

  • Suitable for hazardous areas:

  • ATEX, FM, CSA, IEC Ex, NEPSI

  • Can be connected to all common process control systems:

HART, PROFIBUS DP, Modbus RS485

Spare Parts & Accessories 60

60 spare parts · click to collapse
Order codeDescription
50098557Power board220V = 85-260VACDetails
50098558Explosion-proof power supply board220V = 85-260VACDetails
50098565Power board24V = 20-55VAC / 16-62VDCDetails
50098566Explosion-proof power supply boardKit P.s.b. 40/8X/65 20-55AC 16-62DC ExDetails
50094002fuseKit 10 fuses 250 VAC T800 MADetails
50094003fuseKit Bus/connec.b.5X/40/8X/65 field hous.Details
71008429Integrated Explosion-proof Signal Processing ModuleKit meas.amplifier t-mass 65 compact ExDetails
71008430Separate-Type Explosion-Proof Signal Processing ModuleKit meas.amplifier t-mass 65 remote ExDetails
71008448Preamplifier ModuleKit preamplifier 65 remote sens non ExDetails
50096757Explosion-proof current/frequency output moduleKit com50/40/80/90 curr/Freq.out ExDetails
50098300Explosion-proof Current/Frequency Input Module with 2-Channel Relay OutputKit com 53/83/93/65 curr/freq/2Relay ExDetails
50098302Intrinsically Safe Passive Current/Frequency Output ModuleKit com5X/40/8X/93/65 Iout pass/Freq.ExiDetails
50098303Intrinsically Safe Active Current/Frequency Output ModuleKit com5X/40/8X/93/65 Iout act/Freq.ExiDetails
50104625Intrinsically Safe Active Current Output ModuleKit com 83/65 2x Iout aktiv ExiDetails
50104626Intrinsically Safe Passive Current Output ModuleKit com 83/65 2x Iout passiv ExiDetails
71021742Communication moduleDetails
71095035I/O Board C14 EX53/55/83/93/65Details
71066579I/O board PA Ex50/53/55/80/83/93/65Details
71021743ModbusRS485+stat.In 2Interf.Ex communication module53/83/84/65/8CN/8DFDetails
50096833Explosion-proof output female module with 3-channel interfaceKit Com53/8X/93/65 curr.out 3 Interf.ExDetails

Configurator / Comparison

ConfigureEnter a product model to configure
CompareEnter the product models to compare — up to three products

Source:Endress+Hauserwebsite public information

6 models · click to collapse
Diagnostic codes(49 条)→
All documents for this model
12 documents · click to expand
BA

Proline t-mass 65 HART 操作手册 Chinese

HART Rev. 0610 100 pages
Preview
BA

Proline t-mass 65 MODBUS RS485 Operating Instructions English

Rev. 1414 107 pages
Preview
BA

Proline t-mass 65 MODBUS RS485 Description of the Device Functions English

Rev. 1414 64 pages
Preview
BA

Proline t-mass 65 FOUNDATION Fieldbus Operating Instructions English

FOUNDATION-Fieldbus Rev. 1414 104 pages
Preview
BA

Proline t-mass 65 FOUNDATION Fieldbus Description of the Device Functions English

FOUNDATION-Fieldbus Rev. 1414 124 pages
Preview
BA

Proline t-mass 65 PROFIBUS DP/PA Description of the Device Functions English

PROFIBUS-DP Rev. 1414 60 pages
Preview
BA

Proline t-mass 65 PROFIBUS DP/PA Operating Instructions English

PROFIBUS-DP Rev. 1414 127 pages
Preview
BA

Proline t-mass 65 English

Rev. 1314 86 pages
Preview
BA

Proline t-mass 65 English

Rev. 1314 103 pages
Preview
BA

Proline t-mass 65 HART Description of Device Functions English

HART Rev. 0610 86 pages
Preview
BA

Proline t-mass 65 HART Operating Instructions English

HART Rev. 0610 102 pages
Preview
BA

Proline t-mass 65 MODBUS RS485 Operating Instructions English

100 pages
Preview
Municipal Wastewater Treatment

Municipal Wastewater Treatment · Thermal Gas Mass Flow Meters — Application Case

Customer Profile

The typical setting in Municipal Wastewater Treatment is the inlet, biological and outlet stages of a municipal plant. The measuring point is Thermal Gas Mass Flow Meters; the focus is mass flow of air and fuel gases.

Key Difficulties

Conditions are high solids and corrosive fractions, with large diurnal flow swings and, on top of that, effluent parameters drift and probes foul with sludge and biofilm, which a standard configuration cannot handle for long. The design therefore starts with choosing insertion or in-line type by gas composition, temperature and dust.

Implementation

The scope ran through the flow range: flow solution matched to line size, medium and range. Technically it hinges on choosing insertion or in-line type by gas composition, temperature and dust, and on these requirements: stable compliance with Grade 1A discharge limits and online data reporting.

Customer Benefit

In practice this means direct mass output, making combustion ratios more precise, which cut the workload on the site maintenance team.

Food & Beverage

Food & Beverage · Thermal Gas Mass Flow Meters — Application Case

Project Background

The project covers dosing, pasteurising, filling and CIP stages. The work centres on Thermal Gas Mass Flow Meters and the core task is mass flow of air and fuel gases.

Operating Challenges

The medium and duty are characterised by syrups, dairy and beverages that scale easily, under strict hygienic requirements, and frequent cleaning demands instruments that withstand hot CIP/SIP caustic cycles. So Thermal Gas Mass Flow Meters cannot be specified generically — it calls for choosing insertion or in-line type by gas composition, temperature and dust.

Solution

The Ainstru engineering team worked through the flow range: flow solution matched to line size, medium and range. The configuration involves choosing insertion or in-line type by gas composition, temperature and dust, with these requirements in view: food-safety and hygienic design per 3-A / EHEDG.

Results

Since start-up the system has run steadily; the practical result is direct mass output, making combustion ratios more precise.

Chemical & Pharmaceutical

Chemical & Pharmaceutical · Thermal Gas Mass Flow Meters — Application Case

Project Overview

The site is reactors, metering vessels and finished-product tanks. The customer wanted Thermal Gas Mass Flow Meters properly configured on the existing plant, with the aim of mass flow of air and fuel gases.

Technical Challenges

What actually causes trouble is highly corrosive media with solvents and crystallisation, partly in explosive atmospheres, and corrosion plus Ex protection shortens instrument life and makes downtime costly. All of this means the Thermal Gas Mass Flow Meters configuration has to involve choosing insertion or in-line type by gas composition, temperature and dust.

Configuration

Supply and installation were organised through the flow range: flow solution matched to line size, medium and range. On site this meant choosing insertion or in-line type by gas composition, temperature and dust, checked line by line against: Ex certification and GMP traceability of records.

Performance

After commissioning the outcome is direct mass output, making combustion ratios more precise, and the readings are now used for process tuning.

Power & Energy

Power & Energy · Thermal Gas Mass Flow Meters — Application Case

Site Conditions

This is a Power & Energy customer whose plant is at boiler feedwater, turbine condensate and FGD/DeNOx systems. The main task was mass flow of air and fuel gases.

The Problem

The difficulty lies in high temperature and pressure with both steam and saline water; at the same time drift under high temperature and pressure, with very costly unplanned outages. Specification therefore means choosing insertion or in-line type by gas composition, temperature and dust.

What We Did

We took a flow range approach — flow solution matched to line size, medium and range. Delivery was built around choosing insertion or in-line type by gas composition, temperature and dust, with point-by-point checks on: compliance with power-industry codes and unit availability targets.

Operating Outcome

In service the system performs as intended — direct mass output, making combustion ratios more precise, with routine maintenance falling noticeably.