Instrumentation · Engineering · Package · PLC
0755-8222 1901 sales@ainstru.com

CA80TN Total Nitrogen Analyzer

CA80TN Total Nitrogen Analyzer

Liquiline System CA80TN

Total nitrogen analyzer, suitable for environmental monitoring, industrial wastewater, and municipal sewage applications
Compare

Analyser

Measuring Principle UV photometric
Characteristic Process analyzer for total nitrogen in aqueous solutions
UV photometric method following HJ636-2012
Size Housing (open version):
793 x 530 x 417 mm
31.22 x 20.87 x 16.42 in
Housing (closed version):
793 x 530 x 463 mm
31.22 x 20.87 x 18.23 in
Housing with base:
1723 x 530 x 463 mm
67.83 x 20.87 x 18.23 in
Design Open design, cabinet and stand housing
High-Performance plastic ASA-PC, additional stand coated steel
Process temperature 4 to 40 °C (39.2 to 104 °F)
Ambient temperature 5 to 40 °C (41 to 104 °F)
Process pressure At atmospheric pressure, < 0.2 bar
Sample flow rate Min. 15 ml/min (0.51 fl.oz/min)
Consistency of the sample Aqueous, homogeneous
Application Monitoring of wastewater treatment plant outlet
Monitoring of the surface water quality
Monitoring of industrial water treatment
Monitoring and optimization of industrial wastewater treatment plants
Power supply 100 to 120 VAC / 200 to 240 VAC ± 10%
50 ± 1 or 60 ± 1,2 Hz
Output / communication 2x 0/4 to 20 mA
Modbus RS485/TCP (optional)
Webserver (optional)
Ethernet/IP
Profibus DP
Alarm relay
Input 1 measuring channel
1 to 4 digital sensor inputs for sensors with Memosens protocol (optional)
Measuring range 0 to 20 mg/l N
0 to 50 mg/l N
0 to 250 mg/l N
Consumables Reagents and standard solutions CY80TN as well as cleaner CY800 are necessary for the operation
Regular maintenance is done with the parts of the maintenance kit CAV880

Application areas
Total nitrogen is a key indicator for determining surface water quality and assessing the impact of wastewater discharges. Total nitrogen comprises the organic and inorganic nitrogen present in the water. A rise in the total nitrogen concentration in surface water indicates that it may be affected by sewage from pipe networks, landfill leachate or agricultural non-point source pollution.
The Liquiline System CA80TN total nitrogen analyzer performs highly accurate online total nitrogen measurement, safeguarding process safety. The analyzer features advanced diagnostics, supports remote access, and its archived records can be submitted directly to the authorities as documentary evidence.

The Liquiline System total nitrogen analyzer monitors organic nitrogen compounds (e.g. proteins, urea) and inorganic nitrogen compounds (e.g. nitrate, nitrite, ammonia nitrogen) and is suitable for the following applications:
Inlet and outlet of wastewater treatment plants, for archiving records and calculating purification capacity
Discharge from industrial wastewater treatment plants, for determining discharge fees, as the basis of the “polluter pays principle”
Monitoring surface water quality

Advantages
Complies with the national standard HJ636 “Water quality - Determination of total nitrogen - Alkaline potassium persulfate digestion UV spectrophotometric method”; the measuring results are fully consistent with laboratory results.
Robust and durable: titanium reactor with sapphire window for a long service life.
Flexible to use: built-in dilution unit providing a wide measuring range.
Fast process integration: self-priming analyzer can be used directly and safely; the analyzer with Y-type pretreatment is connected in series in a bypass line.
Simple addition of modules and connection of Memosens digital sensors for easy upgrading to a complete measuring station.

 

E+H Product Model Configurator

Please enter the product model to configure

Product comparison

Please enter the product models to compare in the input fields below; up to three products can be compared

 

   

Technical documentation

   

Technical data

 

 

Documents / Manuals / Software

 

 

Accessories / Spare parts

 

   

Measuring principle video

Source:Endress+Hauserpublic information from the website

Municipal Wastewater Treatment

Municipal Wastewater Treatment — Wastewater Treatment Plant · EH-ONLINE Application Case

Project Background

Municipal Wastewater Treatment customers at the Wastewater Treatment Plant stage have long faced the challenge of insufficient accuracy in effluent quality monitoring and instruments prone to contamination causing data drift, affecting compliance discharge, placing higher demands on the stability and measurement accuracy of EH-ONLINE.

Solution

Based on the on-site conditions, the Ainstru technical team selected suitable EH-ONLINE for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.

Results

  • Measurement accuracy and response speed significantly improved, with stable and reliable data;
  • Instruments adapt to complex Municipal Wastewater Treatment conditions, greatly reducing maintenance;
  • Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.
Food & Beverage

Food & Beverage — Food Production Line · EH-ONLINE Application Case

Project Background

Food & Beverage customers at the Food Production Line stage have long faced the challenge of high hygienic measurement requirements, with inline instruments needing to withstand CIP/SIP cleaning while maintaining stable accuracy, placing higher demands on the stability and measurement accuracy of EH-ONLINE.

Solution

Based on the on-site conditions, the Ainstru technical team selected suitable EH-ONLINE for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.

Results

  • Measurement accuracy and response speed significantly improved, with stable and reliable data;
  • Instruments adapt to complex Food & Beverage conditions, greatly reducing maintenance;
  • Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.
Chemical & Pharmaceutical

Chemical & Pharmaceutical — Reactors and Storage Tanks · EH-ONLINE Application Case

Project Background

Chemical & Pharmaceutical customers at the Reactors and Storage Tanks stage have long faced the challenge of highly corrosive media and complex conditions, requiring corrosion-resistant and explosion-proof instruments, placing higher demands on the stability and measurement accuracy of EH-ONLINE.

Solution

Based on the on-site conditions, the Ainstru technical team selected suitable EH-ONLINE for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.

Results

  • Measurement accuracy and response speed significantly improved, with stable and reliable data;
  • Instruments adapt to complex Chemical & Pharmaceutical conditions, greatly reducing maintenance;
  • Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.
Power & Energy

Power & Energy — Power Plant Boiler and Turbine · EH-ONLINE Application Case

Project Background

Power & Energy customers at the Power Plant Boiler and Turbine stage have long faced the challenge of unstable measurement under high temperature and pressure, with high maintenance and downtime costs, placing higher demands on the stability and measurement accuracy of EH-ONLINE.

Solution

Based on the on-site conditions, the Ainstru technical team selected suitable EH-ONLINE for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.

Results

  • Measurement accuracy and response speed significantly improved, with stable and reliable data;
  • Instruments adapt to complex Power & Energy conditions, greatly reducing maintenance;
  • Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.