Technical Data
CompareLiquid analysis
| Measured parameters | Ammonium (NH4-N), nitrate (NO3-N), potassium, chloride |
| Measuring range | Ammonium 0 to 1000 mg/L; nitrate 0 to 1000 mg/L; potassium 1 to 1000 mg/L; chloride 1 to 1000 mg/L |
| Process temperature | 2 to 40 °C (36 to 104 °F) |
| Process pressure | 500 mbar max. permitted overpressure |
| Ambient temperature | -20 to 55 °C (-4 to 131 °F) |
| Size | Diameter 82 mm; immersion depth 5 m |
| Design | Ion-selective electrode(s) for ammonium and/or nitrate, potassium or chloride; pH (reference) electrode; 3 configurable slots |
| Output / communication | Memosens digital output for Liquiline transmitters |
| Application | Wastewater treatment plants |
Product overview
The Memosens CAS41E is a digital multiparameter sensor that uses ion-selective electrodes (ISE) for continuous measurement of ammonium, nitrate, potassium or chloride, providing reliable control of nitrification and denitrification in municipal wastewater treatment plants. It helps reduce aeration-related energy consumption and supports stable, efficient operation within limits.
Three configurable electrode slots allow flexible combinations of measurement and compensation electrodes in a single sensor, reducing installation effort and system complexity. The fully sealed design permits direct in-process installation, and Memosens technology enables real-time monitoring and dynamic process optimization.
Benefits
- Compact multiparameter sensor: three configurable electrode slots combine measurement and compensation electrodes in one sensor.
- Direct in-process installation: fully sealed design for real-time monitoring and dynamic optimization.
- Smart calibration concept: automated evaluation reduces manual maintenance.
- Lower operating costs: precise nitrification/denitrification control cuts aeration energy.
Field of application
Online nutrient measurement in municipal wastewater treatment plants:
- Nitrification and denitrification control
- Ammonium and nitrate monitoring in the effluent
- Aeration basin process optimization
Measuring principle
Ion-selective electrodes generate a potential related to the ion concentration; an integrated pH (reference) electrode provides the reference. The signal is transmitted digitally via Memosens to Liquiline transmitters. The three slots can be combined with ammonium, nitrate, potassium and chloride electrodes plus compensation electrodes as required.
Configurator / Comparison
Case Studies
Municipal Wastewater Treatment · EH-ONLINE — Application Case
Project Overview
The site is the inlet, biological and outlet stages of a municipal plant. The customer wanted EH-ONLINE properly configured on the existing plant, with the aim of continuous water monitoring on the E+H online platform.
Technical Challenges
What actually causes trouble is high solids and corrosive fractions, with large diurnal flow swings, and effluent parameters drift and probes foul with sludge and biofilm. All of this means the EH-ONLINE configuration has to involve configured under one numbering scheme across platform protocols and sensors.
Configuration
Supply and installation were organised through the online water-analysis line: integrating around each online monitoring point. On site this meant configured under one numbering scheme across platform protocols and sensors, checked line by line against: stable compliance with Grade 1A discharge limits and online data reporting.
Performance
After commissioning the outcome is data flows through the platform, improving service and diagnostics, and the readings are now used for process tuning.
Food & Beverage · EH-ONLINE — Application Case
Site Conditions
This is a Food & Beverage customer whose plant is at dosing, pasteurising, filling and CIP stages. The main task was continuous water monitoring on the E+H online platform.
The Problem
The difficulty lies in syrups, dairy and beverages that scale easily, under strict hygienic requirements; at the same time frequent cleaning demands instruments that withstand hot CIP/SIP caustic cycles. Specification therefore means configured under one numbering scheme across platform protocols and sensors.
What We Did
We took a online water-analysis line approach — integrating around each online monitoring point. Delivery was built around configured under one numbering scheme across platform protocols and sensors, with point-by-point checks on: food-safety and hygienic design per 3-A / EHEDG.
Operating Outcome
In service the system performs as intended — data flows through the platform, improving service and diagnostics, with routine maintenance falling noticeably.
Chemical & Pharmaceutical · EH-ONLINE — Application Case
Application Context
reactors, metering vessels and finished-product tanks is a typical Chemical & Pharmaceutical duty. The project started from EH-ONLINE, focusing on continuous water monitoring on the E+H online platform.
Process Constraints
corrosion plus Ex protection shortens instrument life and makes downtime costly, and highly corrosive media with solvents and crystallisation, partly in explosive atmospheres only amplify it. The EH-ONLINE specification must therefore cover configured under one numbering scheme across platform protocols and sensors.
Delivery Approach
Delivery was handled as the online water-analysis line — integrating around each online monitoring point. Execution centred on configured under one numbering scheme across platform protocols and sensors, together with Ex certification and GMP traceability of records.
Field Results
Operation shows the benefit clearly — data flows through the platform, improving service and diagnostics, with confidence in this measuring point improving markedly.
Power & Energy · EH-ONLINE — Application Case
Customer Profile
The typical setting in Power & Energy is boiler feedwater, turbine condensate and FGD/DeNOx systems. The measuring point is EH-ONLINE; the focus is continuous water monitoring on the E+H online platform.
Key Difficulties
Conditions are high temperature and pressure with both steam and saline water and, on top of that, drift under high temperature and pressure, with very costly unplanned outages, which a standard configuration cannot handle for long. The design therefore starts with configured under one numbering scheme across platform protocols and sensors.
Implementation
The scope ran through the online water-analysis line: integrating around each online monitoring point. Technically it hinges on configured under one numbering scheme across platform protocols and sensors, and on these requirements: compliance with power-industry codes and unit availability targets.
Customer Benefit
In practice this means data flows through the platform, improving service and diagnostics, which cut the workload on the site maintenance team.