Instrumentation · Engineering · Package · PLC
0755-82221901 sales@ainstru.com

CM442R rail type multi parameter water analysis transmitter

CM442R rail type multi parameter water analysis transmitter
Liquiline CM442R
Configurable Models 4 models
Compact multi parameter transmitter, cabinet or DIN rail installation, suitable for various industries
Compare

Conductivity

Measuring Principle Conductive
Application Modular 4 wire controller
Multichannel: 1/2 digital channels for Memosens protocol
Multiparameter: pH, redox, ISFET, conductivity inductive and conductive, dissolved oxygen, nitrate and turbidity
Two sensors connectable in any combination
Functionality modular extendable at any time
Plug and play for modules and sensors
Characteristic Robust plastic housing
All non-ex applications
Design 2x Memosens input, 2 to 4x current output, alarmrelay
2x relay, SD card for software update and copy & paste of setup
Material DIN rail housing: PC-FR
Display seal: EPDM
Dimension 99 x 100 x 97 mm
3.9 x 3.94 x 3.82 inch
Process temperature 0 to 60 °C (32 to 140 °F)
Ingress protection Transmitter: IP20
Optional Display: IP66
Input 1 to 2x Memosens digital input
2x 0/4 to 20mA Input optional
2x Digital input optional
Output / communication 2 to 8x 0/4 to 20 mA current outputs
Alarmrelay, 2x relay, ProfibusDP, Modbus RS485,
Modbus TCP, Ethernet
Certificates, declarations and approvals EAC, cCSAus

Disinfection

Measuring Principle Total chlorine
Application Modular 4 wire controller
Multichannel: 1/2 digital channels for Memosens protocol
Multiparameter: pH, redox, ISFET, conductivity inductive and conductive, dissolved oxygen, nitrate and turbidity
Two sensors connectable in any combination
Functionality modular extendable at any time
Plug and play for modules and sensors
Characteristic Robust plastic housing
All non-ex applications
Design 2x Memosens input, 2 to 4x current output, alarmrelay
2x relay, SD card for software update and copy & paste of setup
Material DIN rail housing: PC-FR
Display seal: EPDM
Dimension 99 x 100 x 97 mm
3.9 x 3.94 x 3.82 inch
Process temperature 0 to 60 °C (32 to 140 °F)
Input 1 to 2x Memosens digital input
2x 0/4 to 20mA Input optional
2x Digital input optional
Output / communication 2 to 8x 0/4 to 20 mA current outputs
Alarmrelay, 2x relay, ProfibusDP, Modbus RS485,
Modbus TCP, Ethernet
Certificates, declarations and approvals EAC, cCSAus

ORP / Redox

Measuring Principle Sensor ORP / Redox
Application Modular 4 wire controller
Multichannel: 1/2 digital channels for Memosens protocol
Multiparameter: pH, redox, ISFET, conductivity inductive and conductive, dissolved oxygen, nitrate and turbidity
Two sensors connectable in any combination
Functionality modular extendable at any time
Plug and play for modules and sensors
Characteristic Robust plastic housing
All non-ex applications
Design 2x Memosens input, 2 to 4x current output, alarmrelay
2x relay, SD card for software update and copy & paste of setup
Material DIN rail housing: PC-FR
Display seal: EPDM
Dimension 99 x 100 x 97 mm
3.9 x 3.94 x 3.82 inch
Process temperature 0 to 60 °C (32 to 140 °F)
Ingress protection Transmitter: IP20
Optional Display: IP66
Input 1 to 2x Memosens digital input
2x 0/4 to 20mA Input optional
2x Digital input optional
Output / communication 2 to 8x 0/4 to 20 mA current outputs
Alarmrelay, 2x relay, ProfibusDP, Modbus RS485,
Modbus TCP, Ethernet
Certificates, declarations and approvals EAC, cCSAus

Oxygen

Measuring Principle Amperometric oxygen measurement
Application Modular 4 wire controller
Multichannel: 1/2 digital channels for Memosens protocol
Multiparameter: pH, redox, ISFET, conductivity inductive and conductive, dissolved oxygen, nitrate and turbidity
Two sensors connectable in any combination
Functionality modular extendable at any time
Plug and play for modules and sensors
Characteristic Robust plastic housing
All non-ex applications
Design 2x Memosens input, 2 to 4x current output, alarmrelay
2x relay, SD card for software update and copy & paste of setup
Material DIN rail housing: PC-FR
Display seal: EPDM
Dimension 99 x 100 x 97 mm
3.9 x 3.94 x 3.82 inch
Process temperature 0 to 60 °C (32 to 140 °F)
Input 1 to 2x Memosens digital input
2x 0/4 to 20mA Input optional
2x Digital input optional
Output / communication 2 to 8x 0/4 to 20 mA current outputs
Alarmrelay, 2x relay, ProfibusDP, Modbus RS485,
Modbus TCP, Ethernet
Certificates, declarations and approvals EAC, cCSAus

Sludge Level

Measuring Principle Ultrasonic sensor
Application Modular 4 wire controller
Multichannel: 1/2 digital channels for Memosens protocol
Multiparameter: pH, redox, ISFET, conductivity inductive and conductive, dissolved oxygen, nitrate and turbidity
Two sensors connectable in any combination
Functionality modular extendable at any time
Plug and play for modules and sensors
Characteristic Robust plastic housing
All non-ex applications
Design 2x Memosens input, 2 to 4x current output, alarmrelay
2x relay, SD card for software update and copy & paste of setup
Material DIN rail housing: PC-FR
Display seal: EPDM
Dimension 99 x 100 x 97 mm
3.9 x 3.94 x 3.82 inch
Process temperature 0 to 60 °C (32 to 140 °F)
Ingress protection Transmitter: IP20
Optional Display: IP66
Input 1 to 2x Memosens digital input
2x 0/4 to 20mA Input optional
2x Digital input optional
Output / communication 2 to 8x 0/4 to 20 mA current outputs
Alarmrelay, 2x relay, ProfibusDP, Modbus RS485,
Modbus TCP, Ethernet
Certificates, declarations and approvals EAC, cCSAus

Turbidity

Measuring Principle Single beam scattered light
Application Modular 4 wire controller
Multichannel: 1/2 digital channels for Memosens protocol
Multiparameter: pH, redox, ISFET, conductivity inductive and conductive, dissolved oxygen, nitrate and turbidity
Two sensors connectable in any combination
Functionality modular extendable at any time
Plug and play for modules and sensors
Characteristic Robust plastic housing
All non-ex applications
Design 2x Memosens input, 2 to 4x current output, alarmrelay
2x relay, SD card for software update and copy & paste of setup
Material DIN rail housing: PC-FR
Display seal: EPDM
Dimension 99 x 100 x 97 mm
3.9 x 3.94 x 3.82 inch
Process temperature 0 to 60 °C (32 to 140 °F)
Ingress protection Transmitter: IP20
Optional Display: IP66
Input 1 to 2x Memosens digital input
2x 0/4 to 20mA Input optional
2x Digital input optional
Output / communication 2 to 8x 0/4 to 20 mA current outputs
Alarmrelay, 2x relay, ProfibusDP, Modbus RS485,
Modbus TCP, Ethernet
Certificates, declarations and approvals EAC, cCSAus

pH

Measuring Principle Potentiometric
Application Modular 4 wire controller
Multichannel: 1/2 digital channels for Memosens protocol
Multiparameter: pH, redox, ISFET, conductivity inductive and conductive, dissolved oxygen, nitrate and turbidity
Two sensors connectable in any combination
Functionality modular extendable at any time
Plug and play for modules and sensors
Characteristic Robust plastic housing
All non-ex applications
Design 2x Memosens input, 2 to 4x current output, alarmrelay
2x relay, SD card for software update and copy & paste of setup
Material DIN rail housing: PC-FR
Display seal: EPDM
Dimension 99 x 100 x 97 mm
3.9 x 3.94 x 3.82 inch
Process temperature 0 to 60 °C (32 to 140 °F)
Ingress protection Transmitter: IP20
Optional Display: IP66
Input 1 to 2x Memosens digital input
2x 0/4 to 20mA Input optional
2x Digital input optional
Output / communication 2 to 8x 0/4 to 20 mA current outputs
Alarmrelay, 2x relay, ProfibusDP, Modbus RS485,
Modbus TCP, Ethernet
Certificates, declarations and approvals EAC, cCSAus

The Liquiline CM442R is an easy-to-use digital multi-parameter transmitter suitable for all kinds of process monitoring and control, and can be used in measurement applications with very limited installation space. Simple and fast system integration, installation and operation save you time and money. The special compact design of the 1-/2-channel controller is suitable for all installation environments. The Liquiline CM442R offers a first-class transmitter platform, easy operation and ensures the highest process safety.

 

Advantages

Space and cost saving, compact, four-channel device, expandable at any time, rail mounting in the control cabinet

Fast installation: no opening in the control cabinet door, one-click DIN rail mounting, minimum wiring

Simple and safe commissioning: communication with other devices via SD card, convenient setup, saving time and costs

Simple operation and service: intuitive user panel, plug-and-play with pre-calibrated Memosens sensors, universal components for all parameters

Process control and safety: via the built-in web server, operators can remotely access diagnostic data and parameter settings, or access device parameters through any web browser - even via smartphone

 

Areas of application

The Liquiline CM442R multi-parameter transmitter is suitable for all non-hazardous areas, including the following industries and their utilities:

 

Food&beverage

Life sciences

Power&energy

Water&wastewater

Chemical industry

The Liquiline CM442R is compatible with all common communication protocols and interfaces, such as:

 

0/4...20 mA

HART

PROFIBUS DP

Modbus TCP / Modbus RS485

EtherNet/IP

Webserver

Spare Parts & Accessories 79

79 spare parts · click to collapse
Order codeDescription
71100607Basic componentpower supply 24V AC/DC, 2x 0/4..20mA Out 2x digital sensor, alarm relay CM442/CSF48Details
7143130024V Basic BASE2-L ModuleDetails
71100611CM442 Power Modulepower supply 100 - 230 V AC 50/60 Hz 2x 0/4..20mA Out 2x digital sensor, alarm relayDetails
71431301CM442:BASE2-H ModuleDetails
711074521 accessory for basic terminal CM442/CM444/CM448/CSF48/CSP44CM442/CM444/CM448/CSF48/CSP44Details
71272410Accessory containing hardware module only: upgrade Modbus TCP or EtherNet via upgrade code(+Webserver) extendable via upgrade code to Modbus TCP or EtherNet/IP CM442/CM444/CM448/CSF48 CM442R/CM444R/CM448RDetails
711110532-channel relay, 2x 0/4..20 mA Out CM442 / CM444 / C2x Relay, 2x 0/4..20mA Out CM442 / CM444 / CM448 / CSF48 CM442R / CM444R / CM448RDetails
71107453AOR terminal module accessory for CM442/CM444/CM448/CSF48, 1 pcCM442/CM444/CM448/CSF48Details
711253752-channel relay CM442 / CM444 / CM448 / CSF48CM442R2x Relay CM442 / CM444 / CM448 / CSF48 CM442R / CM444R / CM448RDetails
711253764-channel relay, 4R accessory for CM442 / CM444 / CM448 / CSF484x Relay CM442 / CM444 / CM448 / CSF48Details
711555811 pc 4R terminal module accessory for CM442/CM444/CM448/CSF48CM442/CM444/CM448/CSF48Details
711356322-channel relay, 2x 0/4..20 mA Out CM442 / CM444 / C2x 0/4..20mA Out CM442 / CM444 / CM448 / CSF48 CM442R / CM444R / CM448RDetails
711555821 x 4AO terminal module accessory for CM442/CM444/CM448/CSF48CM442/CM444/CM448/CSF48Details
711356392-channel 0/4..20 mA input CM442 / CM444 / CM448 / CS2x 0/4..20mA In CM442 / CM444 / CM448 / CSF48 CM442R / CM444R / CM448RDetails
711555831 set includes 2 AI, 485 terminal modules for CM442/CM444/CM448/CSF48CM442/CM444/CM448/CSF48Details
71135638DIO module2x digital in, 2x digital out CM442 / CM444 / CM448 / CSF48 CM442R / CM444R / CM448RDetails
712197841 DIO terminal module accessoryDetails
71135634Communication module: Modul ETH+Modbus TCP(+Webserver) Extendable via upgrade code to Profibus DP or Modbus RS485 or Modbus TCP or EtherNet/IP CM442/CM444/CM448/CSF48 CM442R/CM444R/CM448R Successor kit: 71575177 or 71575178Details
71575177Kit Module 485DPDetails
71575178Kit Modbus 485MB Expansion ModuleDetails

Configurator / Comparison

ConfigureEnter a product model to configure
CompareEnter the product models to compare — up to three products

   

   

 

 

A

A

Source:Endress+Hauserwebsite public information

Measuring principle video

Click to play
4 models · click to collapse
Diagnostic codes(83 条)→
All documents for this model
6 documents · click to expand
BA

BA Liquiline CM442R/CM444R/CM448R Chinese

Rev. 1723 154 pages
Preview
BA

Memosens Chinese

Rev. 0822 208 pages
Preview
BA

BA Liquiline CM442R/CM444R/CM448R English

Rev. 1825 166 pages
Preview
BA

Memosens English

Rev. 0822 228 pages
Preview
TI

TI Liquiline CM442R/CM444R/CM448R Chinese

Rev. 1425 60 pages
Preview
TI

TI Liquiline CM442R/CM444R/CM448R English

Rev. 1425 64 pages
Preview
Municipal Wastewater Treatment

Municipal Wastewater Treatment · multiparameter — Application Case

Application Context

the inlet, biological and outlet stages of a municipal plant is a typical Municipal Wastewater Treatment duty. The project started from multiparameter, focusing on monitoring several water parameters at one measuring point.

Process Constraints

effluent parameters drift and probes foul with sludge and biofilm, and high solids and corrosive fractions, with large diurnal flow swings only amplify it. The multiparameter specification must therefore cover configured by parameter set, mounting and cleaning needs.

Delivery Approach

Delivery was handled as the analyser range — selecting as part of a complete water-analysis system. Execution centred on configured by parameter set, mounting and cleaning needs, together with stable compliance with Grade 1A discharge limits and online data reporting.

Field Results

Operation shows the benefit clearly — one point replacing several single-parameter units, saving capex and upkeep, with confidence in this measuring point improving markedly.

Food & Beverage

Food & Beverage · multiparameter — Application Case

Customer Profile

The typical setting in Food & Beverage is dosing, pasteurising, filling and CIP stages. The measuring point is multiparameter; the focus is monitoring several water parameters at one measuring point.

Key Difficulties

Conditions are syrups, dairy and beverages that scale easily, under strict hygienic requirements and, on top of that, frequent cleaning demands instruments that withstand hot CIP/SIP caustic cycles, which a standard configuration cannot handle for long. The design therefore starts with configured by parameter set, mounting and cleaning needs.

Implementation

The scope ran through the analyser range: selecting as part of a complete water-analysis system. Technically it hinges on configured by parameter set, mounting and cleaning needs, and on these requirements: food-safety and hygienic design per 3-A / EHEDG.

Customer Benefit

In practice this means one point replacing several single-parameter units, saving capex and upkeep, which cut the workload on the site maintenance team.

Chemical & Pharmaceutical

Chemical & Pharmaceutical · multiparameter — Application Case

Project Background

The project covers reactors, metering vessels and finished-product tanks. The work centres on multiparameter and the core task is monitoring several water parameters at one measuring point.

Operating Challenges

The medium and duty are characterised by highly corrosive media with solvents and crystallisation, partly in explosive atmospheres, and corrosion plus Ex protection shortens instrument life and makes downtime costly. So multiparameter cannot be specified generically — it calls for configured by parameter set, mounting and cleaning needs.

Solution

The Ainstru engineering team worked through the analyser range: selecting as part of a complete water-analysis system. The configuration involves configured by parameter set, mounting and cleaning needs, with these requirements in view: Ex certification and GMP traceability of records.

Results

Since start-up the system has run steadily; the practical result is one point replacing several single-parameter units, saving capex and upkeep.

Power & Energy

Power & Energy · multiparameter — Application Case

Project Overview

The site is boiler feedwater, turbine condensate and FGD/DeNOx systems. The customer wanted multiparameter properly configured on the existing plant, with the aim of monitoring several water parameters at one measuring point.

Technical Challenges

What actually causes trouble is high temperature and pressure with both steam and saline water, and drift under high temperature and pressure, with very costly unplanned outages. All of this means the multiparameter configuration has to involve configured by parameter set, mounting and cleaning needs.

Configuration

Supply and installation were organised through the analyser range: selecting as part of a complete water-analysis system. On site this meant configured by parameter set, mounting and cleaning needs, checked line by line against: compliance with power-industry codes and unit availability targets.

Performance

After commissioning the outcome is one point replacing several single-parameter units, saving capex and upkeep, and the readings are now used for process tuning.