Technical Data
CompareConcentration
| Measuring Principle | UV absorbance |
| Application | Transmitter for process photometer and Memosens sensors |
| Characteristic | Robust plastic housing All non-ex applications |
| Measuring range | Photometer: OUSAF12, OUSAF21, OUSAF22, OUSAF44, OUSAF46: 0 to 2.5 AU Max. 50 OD (depending on the optical path length) OUSAF11: 0 to 3 AU 0 to 6 OD (depending on the optical path length) OUSTF10: 0 to 200 FTU 0 to 200 ppm DE OUSBT66: 0 to 4 AU 0 to 8 OD (depending on the optical path length) |
| Design | 1 or 2 process photometer, 0 to 4 Memosens Input 2 to 8x current output, alarmrelay, 4x relay, SD card for software update and copy & paste of setup |
| Material | Housing base and DIN rail housing: PC-FR Housing seal and display seal: EPDM |
| Ingress protection | Cabinet device: IP20 shock protection External display: IP66 Field device: IP 66/67 |
The Liquiline CM44P is the first transmitter that allows simultaneous connection of optical sensors and Memosens sensors, helping you build a complete measuring system for process monitoring, e.g. chromatography, fermentation, phase separation and filtration. This transmitter offers you convenient, seamless system integration, simple operation and a reduced spare parts inventory, saving time and costs. The Liquiline CM44P applies all the advantages of the Liquiline platform to optical sensors.
Advantages
Smart design: one controller for all parameters, including process optical sensors
Economical and convenient measuring point setup: connect two optical sensors and four Memosens sensors to fully meet application requirements
Intuitive user interface and guided menus for simple operation and calibration
Seamless integration into distributed control systems via digital communication protocols, e.g. Modbus, PROFIBUS and Industrial Ethernet (EtherNet/IP)
Process control and safety: built-in web server allows operators to view diagnostic data remotely, perform settings or access device parameters in any web browser - even via smartphone.
DIN panel-mount version in limited space - meets the requirements of system integrators and skids
Application areas
The Liquiline CM44P is particularly suitable for applications in the following industries:
Life sciences
Food & beverage
Chemical
Oil & gas
The Liquiline CM44P is used for all common communication protocols and interfaces, e.g.:
0/4...20 mA
HART
PROFIBUS DP
Modbus
Industrial Ethernet (EtherNet/IP)
Web server
Spare Parts & Accessories 97
97 spare parts · click to collapse
| Order code | Description | |
|---|---|---|
| 71141336 | Basic module2x 0/4..20 mA out, alarm relay 2x digital sensor, with connection cable CM444/CM448 | Details |
| 71431302 | Base module BASE2-ECM44: backplane version 2 and min. firmware 01.07.00 needed. CSFxx: backplane version 2 and min. firmware 01.07.03 needed. CA80: backplane version 2, interface module version 2, control module version 2 and min. firmware 01.08.00 needed. | Details |
| 71293900 | PEM module (uncalibrated) | Details |
| 71313181 | Kit CM44P: module PEM (w. adjustment) | Details |
| 71425822 | Kit CM44P module SEM | Details |
| 71272410 | Accessory containing hardware module only: upgrade Modbus TCP or EtherNet via upgrade code(+Webserver) extendable via upgrade code to Modbus TCP or EtherNet/IP CM442/CM444/CM448/CSF48 CM442R/CM444R/CM448R | Details |
| 71111053 | 2-channel relay, 2x 0/4..20 mA Out CM442 / CM444 / C2x Relay, 2x 0/4..20mA Out CM442 / CM444 / CM448 / CSF48 CM442R / CM444R / CM448R | Details |
| 71125375 | 2-channel relay CM442 / CM444 / CM448 / CSF48CM442R2x Relay CM442 / CM444 / CM448 / CSF48 CM442R / CM444R / CM448R | Details |
| 71125376 | 4-channel relay, 4R accessory for CM442 / CM444 / CM448 / CSF484x Relay CM442 / CM444 / CM448 / CSF48 | Details |
| 71135631 | Module 2DS2x digital sensor CM442 / CM444 / CM448 / CSF48 CM442R / CM444R / CM448R | Details |
| 71135632 | 2-channel relay, 2x 0/4..20 mA Out CM442 / CM444 / C2x 0/4..20mA Out CM442 / CM444 / CM448 / CSF48 CM442R / CM444R / CM448R | Details |
| 71135633 | 4-channel analog output module, 4×0/4…20 mA out4x 0/4..20mA Out CM442 / CM444 / CM448 / CSF48 CM442R / CM444R / CM448R | Details |
| 71135634 | Communication module: Modul ETH+Modbus TCP(+Webserver) Extendable via upgrade code to Profibus DP or Modbus RS485 or Modbus TCP or EtherNet/IP CM442/CM444/CM448/CSF48 CM442R/CM444R/CM448R Successor kit: 71575177 or 71575178 | Details |
| 71575177 | Kit Module 485DP | Details |
| 71575178 | Kit Modbus 485MB Expansion Module | Details |
| 71135639 | 2-channel 0/4..20 mA input CM442 / CM444 / CM448 / CS2x 0/4..20mA In CM442 / CM444 / CM448 / CSF48 CM442R / CM444R / CM448R | Details |
| 71135638 | DIO module2x digital in, 2x digital out CM442 / CM444 / CM448 / CSF48 CM442R / CM444R / CM448R | Details |
| 71155580 | CM444/CM448 Power Connection CableCM444/CM448 | Details |
| 71222277 | CM444R/8R 230V DIN rail power supply | Details |
| 71222279 | CM444R/8R 24V DC DIN rail power supply | Details |
Configurator / Comparison
Accessories / Spare parts
A
A
Source:Endress+Hauserpublic information from the website
Measuring principle video
Click to playManuals & Documents 8
All documents for this modelProduct Videos
View allCase Studies
Municipal Wastewater Treatment · multiparameter — Application Case
Application Context
the inlet, biological and outlet stages of a municipal plant is a typical Municipal Wastewater Treatment duty. The project started from multiparameter, focusing on monitoring several water parameters at one measuring point.
Process Constraints
effluent parameters drift and probes foul with sludge and biofilm, and high solids and corrosive fractions, with large diurnal flow swings only amplify it. The multiparameter specification must therefore cover configured by parameter set, mounting and cleaning needs.
Delivery Approach
Delivery was handled as the analyser range — selecting as part of a complete water-analysis system. Execution centred on configured by parameter set, mounting and cleaning needs, together with stable compliance with Grade 1A discharge limits and online data reporting.
Field Results
Operation shows the benefit clearly — one point replacing several single-parameter units, saving capex and upkeep, with confidence in this measuring point improving markedly.
Food & Beverage · multiparameter — Application Case
Customer Profile
The typical setting in Food & Beverage is dosing, pasteurising, filling and CIP stages. The measuring point is multiparameter; the focus is monitoring several water parameters at one measuring point.
Key Difficulties
Conditions are syrups, dairy and beverages that scale easily, under strict hygienic requirements and, on top of that, frequent cleaning demands instruments that withstand hot CIP/SIP caustic cycles, which a standard configuration cannot handle for long. The design therefore starts with configured by parameter set, mounting and cleaning needs.
Implementation
The scope ran through the analyser range: selecting as part of a complete water-analysis system. Technically it hinges on configured by parameter set, mounting and cleaning needs, and on these requirements: food-safety and hygienic design per 3-A / EHEDG.
Customer Benefit
In practice this means one point replacing several single-parameter units, saving capex and upkeep, which cut the workload on the site maintenance team.
Chemical & Pharmaceutical · multiparameter — Application Case
Project Background
The project covers reactors, metering vessels and finished-product tanks. The work centres on multiparameter and the core task is monitoring several water parameters at one measuring point.
Operating Challenges
The medium and duty are characterised by highly corrosive media with solvents and crystallisation, partly in explosive atmospheres, and corrosion plus Ex protection shortens instrument life and makes downtime costly. So multiparameter cannot be specified generically — it calls for configured by parameter set, mounting and cleaning needs.
Solution
The Ainstru engineering team worked through the analyser range: selecting as part of a complete water-analysis system. The configuration involves configured by parameter set, mounting and cleaning needs, with these requirements in view: Ex certification and GMP traceability of records.
Results
Since start-up the system has run steadily; the practical result is one point replacing several single-parameter units, saving capex and upkeep.
Power & Energy · multiparameter — Application Case
Project Overview
The site is boiler feedwater, turbine condensate and FGD/DeNOx systems. The customer wanted multiparameter properly configured on the existing plant, with the aim of monitoring several water parameters at one measuring point.
Technical Challenges
What actually causes trouble is high temperature and pressure with both steam and saline water, and drift under high temperature and pressure, with very costly unplanned outages. All of this means the multiparameter configuration has to involve configured by parameter set, mounting and cleaning needs.
Configuration
Supply and installation were organised through the analyser range: selecting as part of a complete water-analysis system. On site this meant configured by parameter set, mounting and cleaning needs, checked line by line against: compliance with power-industry codes and unit availability targets.
Performance
After commissioning the outcome is one point replacing several single-parameter units, saving capex and upkeep, and the readings are now used for process tuning.
Related Products
Endress+HauserLiquiline CM442
Endress+HauserLiquiline M CM42
Endress+HauserLiquiline CM14
Endress+HauserLiquiline Compact CM82
Endress+HauserLiquiline CM442R
Endress+HauserMulti-parameter transmitter
Endress+HauserLiquiline CM448
Endress+Hauser