Instrumentation · Engineering · Package · PLC
0755-82221901 sales@ainstru.com

COL37E Memosens

COL37E Memosens
Memosens COL37E
Configurable Models 2 models
The optical oxygen sensor Memosens COL37E capitvates due to easy handling and maintenance. With the Memosens 2.0 operators benefit from true plug and play and effortless adjustments to enhance the oxygen measurement. The sensor act agile in all environments and allows quick checking of oxygen values in aeration tanks, fish farms and surface water.
Compare

Oxygen

Measuring Principle Optical oxygen measurement
Application Measurements in the field of surface water, wastewater and process water
Characteristic Agile digital Memosens 2.0 optical oxygen sensor for laboratory measurements
and random sampling in the field
Measuring range 0 to 330 %SAT
Material Stainless steel
Dimension Diameter: 12 mm (0.47 inch)
Shaft length: 120 mm (4.72 inch)
Process temperature –5 to +60 ˚C (23 to 140 ˚F)
Process pressure 1 bar, not intended for continues measurment in process
Temperature sensor Pt1000
Connection Inductive, digital connection head with Memosens 2.0 technology
Ingress protection IP68

The optical oxygen sensor Memosens COL37E is easy to operate and maintain. It allows simple adjustment to enhance oxygen measurement and has a very fast response time. With Memosens 2.0 technology, operators also benefit from true plug & play. The sensor is highly flexible in all environments and can quickly check oxygen values in aeration basins, fish farms and surface water.

Benefits
C-shaped optical cap eliminates interference from bubbles

  • Optical sensor technology with no electrolyte or polarization time, easy to operate

  • Robust optical spot with a long service life for stable measurement

  • Memosens technology with true plug & play and full traceability

  • Optical measuring principle and seamless design for easy cleaning

  • Temperature compensation and registration via the integrated temperature sensor

  • Supports quality management requirements through tamper-proof stored information such as serial number or calibration history

Applications
The Memosens COL37E is suitable for:

  • Checking online measuring loops

  • Taking sample analyses (on-site and in the laboratory)

  • Measuring at process points where periodic checks are recommended

  • In the following applications:

  • Surface water

  • Wastewater

  • Process water

Spare Parts & Accessories 2

2 spare parts · click to collapse
Order codeDescription
71549958COL37E Maintenance KitDetails
COY8-Zero-Point Gel COY8Zero point: Verification, calibration, adjustment at zero point of oxygen and disinfection sensors ::Amperometric and optical sensors ::12, 25 and 40mm diameter ::Application in the lab, in the fieldEnquire

Configurator / Comparison

ConfigureEnter a product model to configure
CompareEnter the product models to compare — up to three products

   

   

 

 

Source: Endress+Hauserpublic information from the website

2 models · click to collapse
All documents for this model
4 documents · click to expand
BA

Memosens COL37E Chinese

Rev. 0121 16 pages
Preview
BA

Memosens COL37E English

Rev. 0121 20 pages
Preview
TI

Memosens COL37E Chinese

Rev. 0122 8 pages
Preview
TI

Memosens COL37E English

Rev. 0122 8 pages
Preview
Municipal Wastewater Treatment

Municipal Wastewater Treatment · EH-Lab — Application Case

Project Background

The project covers the inlet, biological and outlet stages of a municipal plant. The work centres on EH-Lab and the core task is water and process analysis with E+H laboratory instruments.

Operating Challenges

The medium and duty are characterised by high solids and corrosive fractions, with large diurnal flow swings, and effluent parameters drift and probes foul with sludge and biofilm. So EH-Lab cannot be specified generically — it calls for configured by parameter set, range and calibration practice.

Solution

The Ainstru engineering team worked through the laboratory line: configuring around lab method standards and sample throughput. The configuration involves configured by parameter set, range and calibration practice, with these requirements in view: stable compliance with Grade 1A discharge limits and online data reporting.

Results

Since start-up the system has run steadily; the practical result is consistent with online instruments, making cross-checks easy.

Food & Beverage

Food & Beverage · EH-Lab — Application Case

Project Overview

The site is dosing, pasteurising, filling and CIP stages. The customer wanted EH-Lab properly configured on the existing plant, with the aim of water and process analysis with E+H laboratory instruments.

Technical Challenges

What actually causes trouble is syrups, dairy and beverages that scale easily, under strict hygienic requirements, and frequent cleaning demands instruments that withstand hot CIP/SIP caustic cycles. All of this means the EH-Lab configuration has to involve configured by parameter set, range and calibration practice.

Configuration

Supply and installation were organised through the laboratory line: configuring around lab method standards and sample throughput. On site this meant configured by parameter set, range and calibration practice, checked line by line against: food-safety and hygienic design per 3-A / EHEDG.

Performance

After commissioning the outcome is consistent with online instruments, making cross-checks easy, and the readings are now used for process tuning.

Chemical & Pharmaceutical

Chemical & Pharmaceutical · EH-Lab — Application Case

Site Conditions

This is a Chemical & Pharmaceutical customer whose plant is at reactors, metering vessels and finished-product tanks. The main task was water and process analysis with E+H laboratory instruments.

The Problem

The difficulty lies in highly corrosive media with solvents and crystallisation, partly in explosive atmospheres; at the same time corrosion plus Ex protection shortens instrument life and makes downtime costly. Specification therefore means configured by parameter set, range and calibration practice.

What We Did

We took a laboratory line approach — configuring around lab method standards and sample throughput. Delivery was built around configured by parameter set, range and calibration practice, with point-by-point checks on: Ex certification and GMP traceability of records.

Operating Outcome

In service the system performs as intended — consistent with online instruments, making cross-checks easy, with routine maintenance falling noticeably.

Power & Energy

Power & Energy · EH-Lab — Application Case

Application Context

boiler feedwater, turbine condensate and FGD/DeNOx systems is a typical Power & Energy duty. The project started from EH-Lab, focusing on water and process analysis with E+H laboratory instruments.

Process Constraints

drift under high temperature and pressure, with very costly unplanned outages, and high temperature and pressure with both steam and saline water only amplify it. The EH-Lab specification must therefore cover configured by parameter set, range and calibration practice.

Delivery Approach

Delivery was handled as the laboratory line — configuring around lab method standards and sample throughput. Execution centred on configured by parameter set, range and calibration practice, together with compliance with power-industry codes and unit availability targets.

Field Results

Operation shows the benefit clearly — consistent with online instruments, making cross-checks easy, with confidence in this measuring point improving markedly.