Technical Data
CompareOxygen
| Measuring Principle | Optical oxygen measurement |
| Application | Measurements in the field of surface water, wastewater and process water |
| Characteristic | Agile digital Memosens 2.0 optical oxygen sensor for laboratory measurements and random sampling in the field |
| Measuring range | 0 to 330 %SAT |
| Material | Stainless steel |
| Dimension | Diameter: 12 mm (0.47 inch) Shaft length: 120 mm (4.72 inch) |
| Process temperature | –5 to +60 ˚C (23 to 140 ˚F) |
| Process pressure | 1 bar, not intended for continues measurment in process |
| Temperature sensor | Pt1000 |
| Connection | Inductive, digital connection head with Memosens 2.0 technology |
| Ingress protection | IP68 |
The optical oxygen sensor Memosens COL37E is easy to operate and maintain. It allows simple adjustment to enhance oxygen measurement and has a very fast response time. With Memosens 2.0 technology, operators also benefit from true plug & play. The sensor is highly flexible in all environments and can quickly check oxygen values in aeration basins, fish farms and surface water.
Benefits
C-shaped optical cap eliminates interference from bubbles
-
Optical sensor technology with no electrolyte or polarization time, easy to operate
-
Robust optical spot with a long service life for stable measurement
-
Memosens technology with true plug & play and full traceability
-
Optical measuring principle and seamless design for easy cleaning
-
Temperature compensation and registration via the integrated temperature sensor
-
Supports quality management requirements through tamper-proof stored information such as serial number or calibration history
Applications
The Memosens COL37E is suitable for:
-
Checking online measuring loops
-
Taking sample analyses (on-site and in the laboratory)
-
Measuring at process points where periodic checks are recommended
-
In the following applications:
-
Surface water
-
Wastewater
-
Process water
Spare Parts & Accessories 2
2 spare parts · click to collapse
| Order code | Description | |
|---|---|---|
| 71549958 | COL37E Maintenance Kit | Details |
| COY8- | Zero-Point Gel COY8Zero point: Verification, calibration, adjustment at zero point of oxygen and disinfection sensors ::Amperometric and optical sensors ::12, 25 and 40mm diameter ::Application in the lab, in the field | Enquire |
Configurator / Comparison
Source: Endress+Hauserpublic information from the website
Manuals & Documents 4
All documents for this modelCase Studies
Municipal Wastewater Treatment · EH-Lab — Application Case
Project Background
The project covers the inlet, biological and outlet stages of a municipal plant. The work centres on EH-Lab and the core task is water and process analysis with E+H laboratory instruments.
Operating Challenges
The medium and duty are characterised by high solids and corrosive fractions, with large diurnal flow swings, and effluent parameters drift and probes foul with sludge and biofilm. So EH-Lab cannot be specified generically — it calls for configured by parameter set, range and calibration practice.
Solution
The Ainstru engineering team worked through the laboratory line: configuring around lab method standards and sample throughput. The configuration involves configured by parameter set, range and calibration practice, with these requirements in view: stable compliance with Grade 1A discharge limits and online data reporting.
Results
Since start-up the system has run steadily; the practical result is consistent with online instruments, making cross-checks easy.
Food & Beverage · EH-Lab — Application Case
Project Overview
The site is dosing, pasteurising, filling and CIP stages. The customer wanted EH-Lab properly configured on the existing plant, with the aim of water and process analysis with E+H laboratory instruments.
Technical Challenges
What actually causes trouble is syrups, dairy and beverages that scale easily, under strict hygienic requirements, and frequent cleaning demands instruments that withstand hot CIP/SIP caustic cycles. All of this means the EH-Lab configuration has to involve configured by parameter set, range and calibration practice.
Configuration
Supply and installation were organised through the laboratory line: configuring around lab method standards and sample throughput. On site this meant configured by parameter set, range and calibration practice, checked line by line against: food-safety and hygienic design per 3-A / EHEDG.
Performance
After commissioning the outcome is consistent with online instruments, making cross-checks easy, and the readings are now used for process tuning.
Chemical & Pharmaceutical · EH-Lab — Application Case
Site Conditions
This is a Chemical & Pharmaceutical customer whose plant is at reactors, metering vessels and finished-product tanks. The main task was water and process analysis with E+H laboratory instruments.
The Problem
The difficulty lies in highly corrosive media with solvents and crystallisation, partly in explosive atmospheres; at the same time corrosion plus Ex protection shortens instrument life and makes downtime costly. Specification therefore means configured by parameter set, range and calibration practice.
What We Did
We took a laboratory line approach — configuring around lab method standards and sample throughput. Delivery was built around configured by parameter set, range and calibration practice, with point-by-point checks on: Ex certification and GMP traceability of records.
Operating Outcome
In service the system performs as intended — consistent with online instruments, making cross-checks easy, with routine maintenance falling noticeably.
Power & Energy · EH-Lab — Application Case
Application Context
boiler feedwater, turbine condensate and FGD/DeNOx systems is a typical Power & Energy duty. The project started from EH-Lab, focusing on water and process analysis with E+H laboratory instruments.
Process Constraints
drift under high temperature and pressure, with very costly unplanned outages, and high temperature and pressure with both steam and saline water only amplify it. The EH-Lab specification must therefore cover configured by parameter set, range and calibration practice.
Delivery Approach
Delivery was handled as the laboratory line — configuring around lab method standards and sample throughput. Execution centred on configured by parameter set, range and calibration practice, together with compliance with power-industry codes and unit availability targets.
Field Results
Operation shows the benefit clearly — consistent with online instruments, making cross-checks easy, with confidence in this measuring point improving markedly.
Related Products
Endress+HauserMemosens Lab Cable CYK20
Endress+HauserLiquiline To Go CYM290
Endress+HauserLiquiline Mobile CML18
Endress+HauserLiquiline To Go Ex CYM291
Endress+HauserMemosens CPL51E
Endress+HauserTurbimax CUE25, Handheld Infrared
Endress+HauserTurbimax CUE23, Laboratory Infrared
Endress+Hauser