CPL53E PH电极

 CPL53E PH电极

Memosens CPL53E

The Memosens CPL53E pH glass sensors is the allrounder for use in the laboratory. It covers a huge variety of samples and application: whether check of meausring loops or random sampling. Thanks to Memosens 2.0 it allows reliable measurment and a high accuracy with fast response time. Furthermore, the electrode is long lasting and maintenance free since the sensors have a gel filling.
Compare

pH

Measuring Principle Potentiometric
Application Measurements in standard applications in the laboratory
Characteristic Digital Memosens 2.0 compact gel pH glass sensor for standard use in laboratories
Versatile pH sensor with very fast response time
Measuring range pH 0 to 14 (1 to 12 application range)
Material Glass
Dimension Diameter: 12 mm (0.47 inch)
Shaft length: 120 mm (4.72 inch)
Process temperature –5 to 100 °C (23 to 212 °F) (0 to 80 °C (32 to 176 °F) application range)
Process pressure 1 bar, not intended for continues measurment in process
Temperature sensor NTC 30kΩ
Connection Inductive, digital connection head with Memosens 2.0 technology
Ingress protection IP68

The Memosens CPL53E pH glass sensor is an all-rounder for use in the laboratory. It covers a wide variety of samples and applications: whether checking measuring loops or random sampling. Thanks to Memosens 2.0 technology, the sensor provides reliable, highly accurate measurement and fast response times. In addition, the gel filling makes the electrode durable and maintenance-free.

Benefits
Time-saving random sampling with pre-calibrated sensors, allowing fast and easy sensor changes

Easy handling with the Memosens 2.0 bayonet connector

Supports quality management requirements through tamper-proof data storage (including serial number and calibration history)

Maintenance-free pH electrode, no electrolyte refill required

Temperature compensation via the integrated temperature sensor

Applications
The Memosens CPL53E is suitable for:

Checking online measuring loops

Taking sample analyses (on-site and in the laboratory)

Measuring at process points where periodic checks are recommended

As an aqueous medium in standard applications, e.g. water-based solutions.

 

E+H Product Model Configuration Tool

Please enter the product model to configure

Product comparison

Please enter the product models to compare in the fields below; up to three products can be compared

 

   

Technical documentation

   

Technical data

 

 

Documents/Manuals/Software

 

 

Accessories/Spare parts

 

Source: Endress+Hauserpublic information from the website

Municipal Wastewater Treatment

Municipal Wastewater Treatment — Wastewater Treatment Plant · EH-Lab Application Case

Project Background

Municipal Wastewater Treatment customers at the Wastewater Treatment Plant stage have long faced the challenge of insufficient accuracy in effluent quality monitoring and instruments prone to contamination causing data drift, affecting compliance discharge, placing higher demands on the stability and measurement accuracy of EH-Lab.

Solution

Based on the on-site conditions, the Ainstru technical team selected suitable EH-Lab for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.

Results

  • Measurement accuracy and response speed significantly improved, with stable and reliable data;
  • Instruments adapt to complex Municipal Wastewater Treatment conditions, greatly reducing maintenance;
  • Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.
Food & Beverage

Food & Beverage — Food Production Line · EH-Lab Application Case

Project Background

Food & Beverage customers at the Food Production Line stage have long faced the challenge of high hygienic measurement requirements, with inline instruments needing to withstand CIP/SIP cleaning while maintaining stable accuracy, placing higher demands on the stability and measurement accuracy of EH-Lab.

Solution

Based on the on-site conditions, the Ainstru technical team selected suitable EH-Lab for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.

Results

  • Measurement accuracy and response speed significantly improved, with stable and reliable data;
  • Instruments adapt to complex Food & Beverage conditions, greatly reducing maintenance;
  • Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.
Chemical & Pharmaceutical

Chemical & Pharmaceutical — Reactors and Storage Tanks · EH-Lab Application Case

Project Background

Chemical & Pharmaceutical customers at the Reactors and Storage Tanks stage have long faced the challenge of highly corrosive media and complex conditions, requiring corrosion-resistant and explosion-proof instruments, placing higher demands on the stability and measurement accuracy of EH-Lab.

Solution

Based on the on-site conditions, the Ainstru technical team selected suitable EH-Lab for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.

Results

  • Measurement accuracy and response speed significantly improved, with stable and reliable data;
  • Instruments adapt to complex Chemical & Pharmaceutical conditions, greatly reducing maintenance;
  • Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.
Power & Energy

Power & Energy — Power Plant Boiler and Turbine · EH-Lab Application Case

Project Background

Power & Energy customers at the Power Plant Boiler and Turbine stage have long faced the challenge of unstable measurement under high temperature and pressure, with high maintenance and downtime costs, placing higher demands on the stability and measurement accuracy of EH-Lab.

Solution

Based on the on-site conditions, the Ainstru technical team selected suitable EH-Lab for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.

Results

  • Measurement accuracy and response speed significantly improved, with stable and reliable data;
  • Instruments adapt to complex Power & Energy conditions, greatly reducing maintenance;
  • Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.