Instrumentation · Engineering · Package · PLC
0755-82221901 sales@ainstru.com

CPS11 Analog pH sensor

CPS11  Analog pH sensor
Orbisint CPS11
Configurable Models 15 models
Glass electrode for standard applications
Compare

pH

Measuring Principle Potentiometric
Application Standard applications in process and the environment. Long-term monitoring, processes with little change.
Characteristic Very robust, heavy-duty version / high pressure, integrated potential matching, flat membrane available.
Measuring range pH 0-14
Measuring principle Gel compact electrode with PTFE ring-diaphragm.
Design - all shaft lengths with temperature sensor
- advanced gel technology.
- With dirt-repellent PTFE diaphragm.
Material Glass / PTFE
Dimension Diameter: 12 mm (0.46 inch) shaft length: 120, 225, 360 and 425 mm
(4.68, 8.77, 14.04 and 16,57 inch)
Process temperature max. 135°C (274°F)
Process pressure max. 16 bar (230 psi)
Temperature sensor optional with integrated Pt100 or Pt1000
Ex certification Simple operational equipment, no certification necessary.
Connection TOP68 connection head
Ingress protection IP 68
Certificates, declarations and approvals Biocompatibility validated acc. to ISO 10993-5 USP (current version).
TÜV certificate for pressure resistance 16 bar, min. triple overpressure safety.

Field of application
Orbisint CPS11 is the all-rounder for pH measurement in process and environmental applications. It performs reliably and accurately even in highly alkaline media or hazardous areas. Designed for low maintenance and a long operating life, the sensor offers you best value for money.
Long-term monitoring and limit monitoring of processes with stable process conditions:
- Chemical industry
- Pulp & paper industry
- Power plants (e.g. flue gas washers, boiler feed water)
- Incineration plants
Water treatment:
- Drinking water
- Cooling water
- Well water
With ATEX, FM, CSA approval for use in hazardous areas.

 

Benefits
Robust electrode with long poison diffusion path, requires low maintenance due to large, dirt-repellent PTFE ring diaphragm
Suitable for harsh applications: Process glass for highly alkaline media and pressure-stable up to 16 bar (232 psi)
Optional salt ring for low conductivity applications such as boiler feed water and water for injection

 

pH:

Measuring Principle Potentiometric
Application Standard applications in process and the environment. Long-term monitoring, processes with little change.
Characteristic Very robust, heavy-duty version / high pressure, integrated potential matching, flat membrane available.
Measuring range pH 0-14
Measuring principle Gel compact electrode with PTFE ring-diaphragm.
Design - all shaft lengths with temperature sensor
- advanced gel technology.
- With dirt-repellent PTFE diaphragm.
Material Glass / PTFE
Dimension Diameter: 12 mm (0.46 inch) shaft length: 120, 225, 360 and 425 mm
(4.68, 8.77, 14.04 and 16,57 inch)
Process temperature max. 135°C (274°F)
Process pressure max. 16 bar (230 psi)
Temperature sensor optional with integrated Pt100 or Pt1000
Ex certification Simple operational equipment, no certification necessary.
Connection TOP68 connection head
Ingress protection IP 68
Additional certifications Biocompatibility validated acc. to ISO 10993-5 USP (current version).
TÜV certificate for pressure resistance 16 bar, min. triple overpressure safety.

Measuring principle video

Click to play

Spare Parts & Accessories 3

3 spare parts · click to collapse
Order codeDescription
71538217CPSxx electrode protection cap20 pc protective caps for pH sensors CPSxxDetails
CPY4-KCl electrolyte CPY4For liquid filled electrodesEnquire
CPY20-pH buffer solution CPY20pH quality buffer solution, referenced to primary reference material of PTB and standard reference material of NIST. With calibration certificate buffer solutionEnquire

Configurator / Comparison

ConfigureEnter a product model to configure
CompareEnter the product models to compare — up to three products
15 models · click to collapse
All documents for this model
7 documents · click to expand
BA

BA CPSx1, CPFx1 pH电极 CPSx2, CPFx2 ORP电极 Chinese

Rev. 0426 20 pages
Preview
BA

BA CPSx1, CPFx1 pH sensors CPSx2, CPFx2 ORP sensors English

Rev. 0426 20 pages
Preview
BA

pH-/Redoxsensoren und Referenzhalbzellen pH/ORP sensors and reference half cells Operating Instructions English

Rev. 0217 16 pages
Preview
TI

TI Orbisint CPS11 Chinese

Rev. 1725 12 pages
Preview
TI

技术资料 Orbisint CPS11, CPS11D Chinese

Rev. 0208 12 pages
Preview
TI

TI Orbisint CPS11 English

Rev. 1725 12 pages
Preview
TI

Technical Information Orbisint CPS11/CPS11D English

Rev. 0208 12 pages
Preview
Municipal Wastewater Treatment

Municipal Wastewater Treatment · PH — Application Case

Application Context

the inlet, biological and outlet stages of a municipal plant is a typical Municipal Wastewater Treatment duty. The project started from PH, focusing on continuous pH monitoring for neutralisation and compliance control.

Process Constraints

effluent parameters drift and probes foul with sludge and biofilm, and high solids and corrosive fractions, with large diurnal flow swings only amplify it. The PH specification must therefore cover choosing glass or ISFET sensors by temperature, fluoride content and pressure.

Delivery Approach

Delivery was handled as the analyser range — selecting as part of a complete water-analysis system. Execution centred on choosing glass or ISFET sensors by temperature, fluoride content and pressure, together with stable compliance with Grade 1A discharge limits and online data reporting.

Field Results

Operation shows the benefit clearly — tighter dosing control and lower reagent consumption, with confidence in this measuring point improving markedly.

Food & Beverage

Food & Beverage · PH — Application Case

Customer Profile

The typical setting in Food & Beverage is dosing, pasteurising, filling and CIP stages. The measuring point is PH; the focus is continuous pH monitoring for neutralisation and compliance control.

Key Difficulties

Conditions are syrups, dairy and beverages that scale easily, under strict hygienic requirements and, on top of that, frequent cleaning demands instruments that withstand hot CIP/SIP caustic cycles, which a standard configuration cannot handle for long. The design therefore starts with choosing glass or ISFET sensors by temperature, fluoride content and pressure.

Implementation

The scope ran through the analyser range: selecting as part of a complete water-analysis system. Technically it hinges on choosing glass or ISFET sensors by temperature, fluoride content and pressure, and on these requirements: food-safety and hygienic design per 3-A / EHEDG.

Customer Benefit

In practice this means tighter dosing control and lower reagent consumption, which cut the workload on the site maintenance team.

Chemical & Pharmaceutical

Chemical & Pharmaceutical · PH — Application Case

Project Background

The project covers reactors, metering vessels and finished-product tanks. The work centres on PH and the core task is continuous pH monitoring for neutralisation and compliance control.

Operating Challenges

The medium and duty are characterised by highly corrosive media with solvents and crystallisation, partly in explosive atmospheres, and corrosion plus Ex protection shortens instrument life and makes downtime costly. So PH cannot be specified generically — it calls for choosing glass or ISFET sensors by temperature, fluoride content and pressure.

Solution

The Ainstru engineering team worked through the analyser range: selecting as part of a complete water-analysis system. The configuration involves choosing glass or ISFET sensors by temperature, fluoride content and pressure, with these requirements in view: Ex certification and GMP traceability of records.

Results

Since start-up the system has run steadily; the practical result is tighter dosing control and lower reagent consumption.

Power & Energy

Power & Energy · PH — Application Case

Project Overview

The site is boiler feedwater, turbine condensate and FGD/DeNOx systems. The customer wanted PH properly configured on the existing plant, with the aim of continuous pH monitoring for neutralisation and compliance control.

Technical Challenges

What actually causes trouble is high temperature and pressure with both steam and saline water, and drift under high temperature and pressure, with very costly unplanned outages. All of this means the PH configuration has to involve choosing glass or ISFET sensors by temperature, fluoride content and pressure.

Configuration

Supply and installation were organised through the analyser range: selecting as part of a complete water-analysis system. On site this meant choosing glass or ISFET sensors by temperature, fluoride content and pressure, checked line by line against: compliance with power-industry codes and unit availability targets.

Performance

After commissioning the outcome is tighter dosing control and lower reagent consumption, and the readings are now used for process tuning.