Orbisint CPS11D is the digital all-rounder for process and environmental technology. It measures reliably even in highly alkaline media or hazardous areas. Designed for low maintenance and a long operating life, the electrode offers you best value for money. Orbisint CPS11D is not the latest Memosens generation. To get information on the new Memosens CPS11E sensor with extended functionality, click here.
Compare

pH

Measuring Principle
Application Long-term monitoring, processes with little change
Water and wastewater treatment
Characteristic Analog, digital pH electrodes for standard applications in process and environmental technology
Dirt-repellent PTFE diaphragm, built-in temperature sensor
Measuring range pH 0 to 14
Measuring principle Gel compact electrode with PTFE ring-diaphragm
Design All shaft lengths with temperature sensor
Advanced gel technology
Digital electrode with Memosens technology
Material Glass and PTFE
Dimension Diameter: 12 mm (0.47 inch)
Shaft length: 120, 225 and 360 mm
(4.72, 8.86 and 14.17 inch)
Process temperature 0 to 135 °C (32 to 275 °F)
Process pressure 1 to 17 bar (15 to 246 psi)
Temperature sensor NTC 30k
Ex certification ATEX, FM, CSA, NEPSI
Connection Inductive, digital connection head with Memosens technology
Ingress protection IP68
Certificates, declarations and approvals Also available as SIL version

The Orbisint CPS11D is an all-round electrode for process and environmental engineering. It measures reliably even in highly concentrated alkalis or in hazardous areas. The low-maintenance design and long service life reduce electrode operating costs. With Memosens digital technology, the CPS11D offers maximum process and data integrity combined with simple operation. The electrode is corrosion-resistant and moisture-proof, and supports laboratory calibration and device pre-maintenance.

Benefits:

  • Anti-fouling PTFE annular diaphragm, robust electrode design, long poison diffusion path, low maintenance requirements

  • For harsh conditions: can measure strongly alkaline media, with stable pressure up to 16 bar (232 psi)

  • Optional salt ring for low-conductivity measurement, e.g. boiler feedwater and water for injection

  • Non-contact inductive signal transmission technology greatly increases process safety

  • Stores sensor characteristic parameters for predictive maintenance

  • Reduces process downtime, extends sensor service life and lowers operating costs

Application areas:

  • Long-term monitoring and limit monitoring under stable conditions:
    - Chemical industry
    - Paper industry
    - Power plants (e.g. flue gas scrubbers, boiler feed water)
    - Incineration plants

  • Water treatment:
    - Drinking water
    - Cooling water
    - Well water

ATEX, FM, CSA approved, suitable for explosion hazardous areas

Commonly used model: CPS11D-7BA21

 

Spare Parts & Accessories 4

4 spare parts · click to expand
Order codeDescription
71038228***传感器for assignment of sensors to measuring loop. 100 sensor clips with printable labelsEnquire
71538217CPSxx 电极保护帽20 pc protective caps for pH sensors CPSxxEnquire
CPY4-KCl电解液 CPY4For liquid filled electrodesEnquire
CPY20-PH 标液 CPY20pH quality buffer solution, referenced to primary reference material of PTB and standard reference material of NIST. With calibration certificate buffer solutionEnquire

Configurator / Comparison

ConfigureEnter a product model to configure
CompareEnter the product models to compare — up to three products

   

   

 

 

A

Measuring principle video

Click to play

Source: public information from the Endress+Hauser website

9 models · click to expand
Model Name
CPS11D-7BA21 pH electrode
CPS11D-7BT21 pH electrode
CPS11D-7AA21 pH electrode
CPS11D-7BA2G pH electrode
CPS11D-7FA21 pH electrode
CPS11D-7BT2G pH electrode
CPS11D-7BA41 pH electrode
CPS11D-7AS2G pH electrode
CPS11D-7AS21 pH electrode
All documents for this model
7 documents · click to expand
BA

BA CPSx1, CPFx1 pH电极 CPSx2, CPFx2 ORP电极 Chinese

Rev. 0426 20 pages
Preview
BA

BA CPSx1, CPFx1 pH sensors CPSx2, CPFx2 ORP sensors English

Rev. 0426 20 pages
Preview
BA

pH-/Redoxsensoren und Referenzhalbzellen pH/ORP sensors and reference half cells Operating Instructions English

Rev. 0217 16 pages
Preview
TI

TI Orbisint CPS11 Chinese

Rev. 1725 12 pages
Preview
TI

技术资料 Orbisint CPS11, CPS11D Chinese

Rev. 0208 12 pages
Preview
TI

TI Orbisint CPS11 English

Rev. 1725 12 pages
Preview
TI

Technical Information Orbisint CPS11/CPS11D English

Rev. 0208 12 pages
Preview
Municipal Wastewater Treatment

Municipal Wastewater Treatment · PH — Application Case

Application Context

the inlet, biological and outlet stages of a municipal plant is a typical Municipal Wastewater Treatment duty. The project started from PH, focusing on continuous pH monitoring for neutralisation and compliance control.

Process Constraints

effluent parameters drift and probes foul with sludge and biofilm, and high solids and corrosive fractions, with large diurnal flow swings only amplify it. The PH specification must therefore cover choosing glass or ISFET sensors by temperature, fluoride content and pressure.

Delivery Approach

Delivery was handled as the analyser range — selecting as part of a complete water-analysis system. Execution centred on choosing glass or ISFET sensors by temperature, fluoride content and pressure, together with stable compliance with Grade 1A discharge limits and online data reporting.

Field Results

Operation shows the benefit clearly — tighter dosing control and lower reagent consumption, with confidence in this measuring point improving markedly.

Food & Beverage

Food & Beverage · PH — Application Case

Customer Profile

The typical setting in Food & Beverage is dosing, pasteurising, filling and CIP stages. The measuring point is PH; the focus is continuous pH monitoring for neutralisation and compliance control.

Key Difficulties

Conditions are syrups, dairy and beverages that scale easily, under strict hygienic requirements and, on top of that, frequent cleaning demands instruments that withstand hot CIP/SIP caustic cycles, which a standard configuration cannot handle for long. The design therefore starts with choosing glass or ISFET sensors by temperature, fluoride content and pressure.

Implementation

The scope ran through the analyser range: selecting as part of a complete water-analysis system. Technically it hinges on choosing glass or ISFET sensors by temperature, fluoride content and pressure, and on these requirements: food-safety and hygienic design per 3-A / EHEDG.

Customer Benefit

In practice this means tighter dosing control and lower reagent consumption, which cut the workload on the site maintenance team.

Chemical & Pharmaceutical

Chemical & Pharmaceutical · PH — Application Case

Project Background

The project covers reactors, metering vessels and finished-product tanks. The work centres on PH and the core task is continuous pH monitoring for neutralisation and compliance control.

Operating Challenges

The medium and duty are characterised by highly corrosive media with solvents and crystallisation, partly in explosive atmospheres, and corrosion plus Ex protection shortens instrument life and makes downtime costly. So PH cannot be specified generically — it calls for choosing glass or ISFET sensors by temperature, fluoride content and pressure.

Solution

The Ainstru engineering team worked through the analyser range: selecting as part of a complete water-analysis system. The configuration involves choosing glass or ISFET sensors by temperature, fluoride content and pressure, with these requirements in view: Ex certification and GMP traceability of records.

Results

Since start-up the system has run steadily; the practical result is tighter dosing control and lower reagent consumption.

Power & Energy

Power & Energy · PH — Application Case

Project Overview

The site is boiler feedwater, turbine condensate and FGD/DeNOx systems. The customer wanted PH properly configured on the existing plant, with the aim of continuous pH monitoring for neutralisation and compliance control.

Technical Challenges

What actually causes trouble is high temperature and pressure with both steam and saline water, and drift under high temperature and pressure, with very costly unplanned outages. All of this means the PH configuration has to involve choosing glass or ISFET sensors by temperature, fluoride content and pressure.

Configuration

Supply and installation were organised through the analyser range: selecting as part of a complete water-analysis system. On site this meant choosing glass or ISFET sensors by temperature, fluoride content and pressure, checked line by line against: compliance with power-industry codes and unit availability targets.

Performance

After commissioning the outcome is tighter dosing control and lower reagent consumption, and the readings are now used for process tuning.