Ceragel CPS71D is the digital specialist for demanding processes and hygienic applications. Its contamination-resistant gel guarantees stable measurement even in flowing media or low conductivity. The sensor measures reliably at high temperatures and is non-toxic assuring highest safety. Ceragel CPS71D is not the latest Memosens generation. To get information on the new Memosens CPS71E sensor with extended functionality, click here.
Compare

pH

Measuring Principle
Application Aggressive chemical and hygienic applications, process
Characteristic Analog, digital pH single-rod measuring cells
For chemical process, hygienic and sterile applications with an ion trap for poison-resistant reference
Measuring range pH 0 to 14
Measuring principle Ceramic diaphragm, ion-trap
Design All shaft lengths with temperature sensor
Advanced gel technology
Digital electrode with Memosens technology
Material Glass and ceramic
Dimension Diameter: 12 mm (0.47 inch)
Shaft lengths: 120, 225, 360 and 425 mm
(4.72, 8.86, 14.2 and 16.7 inch)
Process temperature 0 to 140 °C (32 to 284 °F)
Process pressure 1 to 14 bar (15 to 203 psi)
Temperature sensor NTC 30k
Ex certification ATEX, FM, CSA
Connection Inductive, digital connection head with Memosens technology
Ingress protection IP68
Certificates, declarations and approvals 3A, biocompatibility

The Memosens CPS71D electrode is especially suitable for demanding applications. With its unique fouling-resistant reference system and moisture-proof, waterproof design, it reliably measures heavily contaminated media and corrosive media such as strong acids and alkalis. The CPS71D electrode uses Memosens digital technology, supports extended data storage of calibration and process parameters, and is the perfect basis for predictive maintenance. Sensors can be precalibrated in the laboratory and replaced quickly on site, minimizing production interruptions.

Benefits
The electrode's unique ion trap effectively prevents toxic diffusion in the lead and reference system, enabling measurement of strong acids and alkalis with a long electrode service life.
Optional pressurized reference system for reliable measurement of media prone to clogging, such as dispersions.
Allows inverted electrode installation for flexible mounting.
Inductive cable connection and non-contact signal transmission eliminate the influence of moisture and corrosion, improving process integrity.
Fast electrode replacement on site shortens production downtime and reduces operating costs.
Memosens digital technology supports extended data storage for calibration and process parameters, enabling trend detection and predictive maintenance. It is also the ideal foundation for advancing IIoT technology.

Application areas
Chemical process engineering and process monitoring:
Highly toxic media, e.g. H2S
Rapidly fluctuating pH values
Approved for ATEX, IECEx, CSA C/US, NEPSI, Japan and INMETRO; suitable for use in explosion protection zones 0, 1 and 2.

 

Commonly used model: CPS71D-7TB21

Spare Parts & Accessories 4

4 spare parts · click to collapse
Order codeDescription
71038228*** sensorfor assignment of sensors to measuring loop. 100 sensor clips with printable labelsDetails
71538217CPSxx electrode protection cap20 pc protective caps for pH sensors CPSxxDetails
CPY4-KCl electrolyte CPY4For liquid filled electrodesEnquire
CPY20-pH buffer solution CPY20pH quality buffer solution, referenced to primary reference material of PTB and standard reference material of NIST. With calibration certificate buffer solutionEnquire

Configurator / Comparison

ConfigureEnter a product model to configure
CompareEnter the product models to compare — up to three products

   

   

 

 

A

A

   

Measuring principle video

Click to play

Source: public information from the Endress+Hauser website

7 models · click to collapse
All documents for this model
8 documents · click to expand
BA

BA CPSx1, CPFx1 pH电极 CPSx2, CPFx2 ORP电极 Chinese

Rev. 0426 20 pages
Preview
BA

BA CPSx1, CPFx1 pH sensors CPSx2, CPFx2 ORP sensors English

Rev. 0426 20 pages
Preview
BA

pH-/Redoxsensoren und Referenzhalbzellen pH/ORP sensors and reference half cells Operating Instructions English

Rev. 0217 16 pages
Preview
TI

TI Ceragel CPS71 Chinese

Rev. 1625 16 pages
Preview
TI

技术资料 Ceragel CPS71, CPS71D Chinese

Rev. 1312 16 pages
Preview
TI

技术资料 Ceragel CPS71, CPS71D Chinese

Rev. 1005 12 pages
Preview
TI

TI Ceragel CPS71 English

Rev. 1625 16 pages
Preview
TI

Technical Information Ceragel CPS71/CPS71D English

12 pages
Preview
Municipal Wastewater Treatment

Municipal Wastewater Treatment · PH — Application Case

Application Context

the inlet, biological and outlet stages of a municipal plant is a typical Municipal Wastewater Treatment duty. The project started from PH, focusing on continuous pH monitoring for neutralisation and compliance control.

Process Constraints

effluent parameters drift and probes foul with sludge and biofilm, and high solids and corrosive fractions, with large diurnal flow swings only amplify it. The PH specification must therefore cover choosing glass or ISFET sensors by temperature, fluoride content and pressure.

Delivery Approach

Delivery was handled as the analyser range — selecting as part of a complete water-analysis system. Execution centred on choosing glass or ISFET sensors by temperature, fluoride content and pressure, together with stable compliance with Grade 1A discharge limits and online data reporting.

Field Results

Operation shows the benefit clearly — tighter dosing control and lower reagent consumption, with confidence in this measuring point improving markedly.

Food & Beverage

Food & Beverage · PH — Application Case

Customer Profile

The typical setting in Food & Beverage is dosing, pasteurising, filling and CIP stages. The measuring point is PH; the focus is continuous pH monitoring for neutralisation and compliance control.

Key Difficulties

Conditions are syrups, dairy and beverages that scale easily, under strict hygienic requirements and, on top of that, frequent cleaning demands instruments that withstand hot CIP/SIP caustic cycles, which a standard configuration cannot handle for long. The design therefore starts with choosing glass or ISFET sensors by temperature, fluoride content and pressure.

Implementation

The scope ran through the analyser range: selecting as part of a complete water-analysis system. Technically it hinges on choosing glass or ISFET sensors by temperature, fluoride content and pressure, and on these requirements: food-safety and hygienic design per 3-A / EHEDG.

Customer Benefit

In practice this means tighter dosing control and lower reagent consumption, which cut the workload on the site maintenance team.

Chemical & Pharmaceutical

Chemical & Pharmaceutical · PH — Application Case

Project Background

The project covers reactors, metering vessels and finished-product tanks. The work centres on PH and the core task is continuous pH monitoring for neutralisation and compliance control.

Operating Challenges

The medium and duty are characterised by highly corrosive media with solvents and crystallisation, partly in explosive atmospheres, and corrosion plus Ex protection shortens instrument life and makes downtime costly. So PH cannot be specified generically — it calls for choosing glass or ISFET sensors by temperature, fluoride content and pressure.

Solution

The Ainstru engineering team worked through the analyser range: selecting as part of a complete water-analysis system. The configuration involves choosing glass or ISFET sensors by temperature, fluoride content and pressure, with these requirements in view: Ex certification and GMP traceability of records.

Results

Since start-up the system has run steadily; the practical result is tighter dosing control and lower reagent consumption.

Power & Energy

Power & Energy · PH — Application Case

Project Overview

The site is boiler feedwater, turbine condensate and FGD/DeNOx systems. The customer wanted PH properly configured on the existing plant, with the aim of continuous pH monitoring for neutralisation and compliance control.

Technical Challenges

What actually causes trouble is high temperature and pressure with both steam and saline water, and drift under high temperature and pressure, with very costly unplanned outages. All of this means the PH configuration has to involve choosing glass or ISFET sensors by temperature, fluoride content and pressure.

Configuration

Supply and installation were organised through the analyser range: selecting as part of a complete water-analysis system. On site this meant choosing glass or ISFET sensors by temperature, fluoride content and pressure, checked line by line against: compliance with power-industry codes and unit availability targets.

Performance

After commissioning the outcome is tighter dosing control and lower reagent consumption, and the readings are now used for process tuning.