Instrumentation · Engineering · Package · PLC
0755-82221901 sales@ainstru.com

CPS171D MemosensDiscontinued

CPS171D Memosens
CPS171D MemosensDiscontinued
Endress+Hauser CPS171D
Configurable Models 4 models
Keep the pH value of your batch in the optimum range and maximize your product yield with Memosens CPS171D. Thanks to its rugged design and long-term stability, it provides extremely accurate, reproducible and reliable measuring values even after CIP/SIP and autoclaving. Memosens CPS171D is not the latest Memosens generation. To get information on the new Memosens CPS61E sensor with extended functionality, click here.
Compare

pH

Measuring Principle
Application Hygienic and sterile applications, bioreactor, fermenter, biotechnology, pharmaceutical industry, foods
Characteristic Digital pH electrodes for bioreactors and biotechnology production processes with ion
trap for long-term stable reference
Measuring range pH 0 to 14
Measuring principle Ceramic diaphragm, ion-trap
Design All shaft lengths with temperature sensor
Advanced gel technology
Digital electrode with Memosens technology
Material Glass and ceramic
Dimension Diameter: 12 mm (0.47 inch)
Shaft lengths: 120, 225, 360 and 425 mm
(4.72, 8.86, 14.2 and 16.7 inch)
Process temperature 0 to 135 °C (32 to 275 °F)
Process pressure 1 to 7 bar abs (14.5 to 101.5 psi)
Temperature sensor NTC 30k
Ex certification IECEx, ATEX, NEPSI, FM, CSA
Connection Inductive, digital connection head with Memosens technology

The Memosens CPS171D ensures stable pH values in batch production for maximum batch yield! The electrode is robust and highly stable over the long term, providing highly accurate, reproducible and reliable measured values even after CIP/SIP cleaning and autoclaving. With Memosens digital technology, the CPS171D offers maximum process and data integrity and is simple to operate. The electrode is corrosion-resistant and moisture-proof, allows laboratory calibration and simplifies predictive maintenance.

Benefits
The high measurement accuracy, reproducibility and reliability of the electrode keep the pH value in the optimum range at all times, maximizing batch yield.
The electrode with its special glass membrane and reference system withstands CIP/SIP cleaning and autoclaving (max. 140°C (284°F)) with the highest long-term stability.
With Memosens technology, the cable connection is protected from moisture or corrosion: the electrode has the widest range of application and batch production safety.
The electrode is biocompatibility-certified in accordance with USP Cl. VI, uses FDA-approved materials for wetted parts, and is free of toxic, biologically active or animal-derived materials, reliably ensuring product quality.
The electrode provides process and sensor parameters that help you determine, before the next batch begins, whether the electrode is ready or should be replaced, greatly improving product safety.
The Memobase Plus software automatically stores and archives all relevant sensor and process parameters for CPS171D series maintenance.
Hazardous area approval.

Applications
The Memosens CPS171D measures pH in the following industries:
Biotechnology and pharmaceutical industry
- Bioreactors/fermenters: fermentation process control
- Bioreactors/fermenters: cell growth control
Food & beverage
- CIP/SIP applications
With international explosion-protection approvals, e.g. ATEX and IECEx, the digital sensor can be used in hazardous areas.
Compliance documentation for the pharmaceutical industry is provided, together with the electrode serial number.

 

Spare Parts & Accessories 4

4 spare parts · click to collapse
Order codeDescription
71038228*** sensorfor assignment of sensors to measuring loop. 100 sensor clips with printable labelsDetails
71538217CPSxx electrode protection cap20 pc protective caps for pH sensors CPSxxDetails
CPY4-KCl electrolyte CPY4For liquid filled electrodesEnquire
CPY20-pH buffer solution CPY20pH quality buffer solution, referenced to primary reference material of PTB and standard reference material of NIST. With calibration certificate buffer solutionEnquire

Configurator / Comparison

ConfigureEnter a product model to configure
CompareEnter the product models to compare — up to three products

   

   

 

 

A

A

A

Source: Endress+Hauserpublic information from the website

Measuring principle video

Click to play
4 models · click to collapse
All documents for this model
5 documents · click to expand
BA

BA CPSx1, CPFx1 pH电极 CPSx2, CPFx2 ORP电极 Chinese

Rev. 0426 20 pages
Preview
BA

BA CPSx1, CPFx1 pH sensors CPSx2, CPFx2 ORP sensors English

Rev. 0426 20 pages
Preview
BA

pH-/Redoxsensoren und Referenzhalbzellen pH/ORP sensors and reference half cells Operating Instructions English

Rev. 0217 16 pages
Preview
TI

技术资料 Memosens CPS171D Chinese

Rev. 0115 12 pages
Preview
TI

Memosens CPS171D Technical Information English

Rev. 0218 16 pages
Preview
Municipal Wastewater Treatment

Municipal Wastewater Treatment · PH — Application Case

Application Context

the inlet, biological and outlet stages of a municipal plant is a typical Municipal Wastewater Treatment duty. The project started from PH, focusing on continuous pH monitoring for neutralisation and compliance control.

Process Constraints

effluent parameters drift and probes foul with sludge and biofilm, and high solids and corrosive fractions, with large diurnal flow swings only amplify it. The PH specification must therefore cover choosing glass or ISFET sensors by temperature, fluoride content and pressure.

Delivery Approach

Delivery was handled as the analyser range — selecting as part of a complete water-analysis system. Execution centred on choosing glass or ISFET sensors by temperature, fluoride content and pressure, together with stable compliance with Grade 1A discharge limits and online data reporting.

Field Results

Operation shows the benefit clearly — tighter dosing control and lower reagent consumption, with confidence in this measuring point improving markedly.

Food & Beverage

Food & Beverage · PH — Application Case

Customer Profile

The typical setting in Food & Beverage is dosing, pasteurising, filling and CIP stages. The measuring point is PH; the focus is continuous pH monitoring for neutralisation and compliance control.

Key Difficulties

Conditions are syrups, dairy and beverages that scale easily, under strict hygienic requirements and, on top of that, frequent cleaning demands instruments that withstand hot CIP/SIP caustic cycles, which a standard configuration cannot handle for long. The design therefore starts with choosing glass or ISFET sensors by temperature, fluoride content and pressure.

Implementation

The scope ran through the analyser range: selecting as part of a complete water-analysis system. Technically it hinges on choosing glass or ISFET sensors by temperature, fluoride content and pressure, and on these requirements: food-safety and hygienic design per 3-A / EHEDG.

Customer Benefit

In practice this means tighter dosing control and lower reagent consumption, which cut the workload on the site maintenance team.

Chemical & Pharmaceutical

Chemical & Pharmaceutical · PH — Application Case

Project Background

The project covers reactors, metering vessels and finished-product tanks. The work centres on PH and the core task is continuous pH monitoring for neutralisation and compliance control.

Operating Challenges

The medium and duty are characterised by highly corrosive media with solvents and crystallisation, partly in explosive atmospheres, and corrosion plus Ex protection shortens instrument life and makes downtime costly. So PH cannot be specified generically — it calls for choosing glass or ISFET sensors by temperature, fluoride content and pressure.

Solution

The Ainstru engineering team worked through the analyser range: selecting as part of a complete water-analysis system. The configuration involves choosing glass or ISFET sensors by temperature, fluoride content and pressure, with these requirements in view: Ex certification and GMP traceability of records.

Results

Since start-up the system has run steadily; the practical result is tighter dosing control and lower reagent consumption.

Power & Energy

Power & Energy · PH — Application Case

Project Overview

The site is boiler feedwater, turbine condensate and FGD/DeNOx systems. The customer wanted PH properly configured on the existing plant, with the aim of continuous pH monitoring for neutralisation and compliance control.

Technical Challenges

What actually causes trouble is high temperature and pressure with both steam and saline water, and drift under high temperature and pressure, with very costly unplanned outages. All of this means the PH configuration has to involve choosing glass or ISFET sensors by temperature, fluoride content and pressure.

Configuration

Supply and installation were organised through the analyser range: selecting as part of a complete water-analysis system. On site this meant choosing glass or ISFET sensors by temperature, fluoride content and pressure, checked line by line against: compliance with power-industry codes and unit availability targets.

Performance

After commissioning the outcome is tighter dosing control and lower reagent consumption, and the readings are now used for process tuning.