Technical Data
ComparepH
| Measuring Principle | Potentiometric |
| Application | Food production, beverage production, quality control, pharmaceutical industry, biotechnology |
| Characteristic | Electrode with pH sensitive enamel and digital Memosens technology Meets highest demands of measuring accuracy, pressure, temperature, sterility and durability |
| Measuring range | 0 to 10 pH (linear range) -2 to 14 pH (application) |
| Measuring principle | Ground diaphragm, liquid KCl-filled reference |
| Design | Only one shaft length, different hygienic process connectors Integrated temperature sensor |
| Material | pH sensitive enamel on a steel carrier |
| Dimension | Diameter: 12 mm (0.47 inch) Shaft length: 120 mm (4.72 inch) |
| Process temperature | 0 to 140 °C (32 to 280 °F) |
| Process pressure | 0.8 to 7 bar abs (11.6 to 101.5 psi) |
| Temperature sensor | NTC 30KΩ |
| Connection | Contactless, inductive, digital connection head with Memosens technology |
The Ceramax CPS341D is a durable electrode for hygienic measuring applications in the food and life sciences industries. The electrode guarantees long-term stability and minimal maintenance requirements. With Memosens digital technology, the CPS341D offers maximum process and data integrity and is simple to operate. The electrode is corrosion-resistant and moisture-proof, and allows laboratory calibration and predictive maintenance.
Benefits
Long-term stability even after years of operation
Hygienic design: suitable for CIP and SIP
Stainless steel body with pH-sensitive enamel coating for high mechanical stability
Large pH measuring surface, insensitive to contamination
Non-contact inductive signal transmission for increased process safety
Storage of sensor characteristic parameters enables predictive maintenance
Reduced process downtime, extended sensor service life and lower operating costs
Applications
Food industry, suitable for pasty media
Beer production and bottling
Life sciences:
- Water treatment
- Surfactant production
- Surfactant pretreatment
- Biotechnology
Spare Parts & Accessories 21
21 spare parts · click to collapse
| Order code | Description | |
|---|---|---|
| 71118068 | CPS341 O-ring | Details |
| 71118070 | CPS341 O-ring | Details |
| 71118071 | CPS341D O-ring | Details |
| 71118072 | CPS341D Gasket Clip | Details |
| 71118073 | CPS341D Variable Insertion Reservoir | Details |
| 71118074 | CPS341D stylus holder | Details |
| 71118075 | CPS341D electrical connection for water reservoir | Details |
| 71300741 | CPS341D spare parts: KCL connection sensor | Details |
| 71300743 | CPS341D Spare Parts: Electrolyte Hose | Details |
| 71300744 | CPS341D spare part: KCl pool hose connection | Details |
| 71300746 | CPS341D Spare Part: Needle Electrolyte Cell | Details |
| 71330336 | CPS341D spare part: DN25 faucet connector | Details |
| 71330337 | CPS341D spare part: DN30 tap connector | Details |
| 71330338 | CPS341D Spare Parts: DN50 Various Fittings | Details |
| 71330339 | CPS341D spare part: DN50 dairy fitting | Details |
| 71330340 | CPS341D spare part: DN25 dairy fitting | Details |
| 71330341 | CPS341D spare parts: DN25 Tri-Clamp fitting | Details |
| 71038229 | *** cablefor assignment of Sensors to measuring loop. 50 cable labels with printable labels. | Details |
| CPS341Z- | CPS41D accessories | Enquire |
| 71038228 | *** sensorfor assignment of sensors to measuring loop. 100 sensor clips with printable labels | Details |
Configurator / Comparison
A
A
Measuring principle video
Click to playManuals & Documents 6
All documents for this modelCase Studies
Municipal Wastewater Treatment · PH — Application Case
Application Context
the inlet, biological and outlet stages of a municipal plant is a typical Municipal Wastewater Treatment duty. The project started from PH, focusing on continuous pH monitoring for neutralisation and compliance control.
Process Constraints
effluent parameters drift and probes foul with sludge and biofilm, and high solids and corrosive fractions, with large diurnal flow swings only amplify it. The PH specification must therefore cover choosing glass or ISFET sensors by temperature, fluoride content and pressure.
Delivery Approach
Delivery was handled as the analyser range — selecting as part of a complete water-analysis system. Execution centred on choosing glass or ISFET sensors by temperature, fluoride content and pressure, together with stable compliance with Grade 1A discharge limits and online data reporting.
Field Results
Operation shows the benefit clearly — tighter dosing control and lower reagent consumption, with confidence in this measuring point improving markedly.
Food & Beverage · PH — Application Case
Customer Profile
The typical setting in Food & Beverage is dosing, pasteurising, filling and CIP stages. The measuring point is PH; the focus is continuous pH monitoring for neutralisation and compliance control.
Key Difficulties
Conditions are syrups, dairy and beverages that scale easily, under strict hygienic requirements and, on top of that, frequent cleaning demands instruments that withstand hot CIP/SIP caustic cycles, which a standard configuration cannot handle for long. The design therefore starts with choosing glass or ISFET sensors by temperature, fluoride content and pressure.
Implementation
The scope ran through the analyser range: selecting as part of a complete water-analysis system. Technically it hinges on choosing glass or ISFET sensors by temperature, fluoride content and pressure, and on these requirements: food-safety and hygienic design per 3-A / EHEDG.
Customer Benefit
In practice this means tighter dosing control and lower reagent consumption, which cut the workload on the site maintenance team.
Chemical & Pharmaceutical · PH — Application Case
Project Background
The project covers reactors, metering vessels and finished-product tanks. The work centres on PH and the core task is continuous pH monitoring for neutralisation and compliance control.
Operating Challenges
The medium and duty are characterised by highly corrosive media with solvents and crystallisation, partly in explosive atmospheres, and corrosion plus Ex protection shortens instrument life and makes downtime costly. So PH cannot be specified generically — it calls for choosing glass or ISFET sensors by temperature, fluoride content and pressure.
Solution
The Ainstru engineering team worked through the analyser range: selecting as part of a complete water-analysis system. The configuration involves choosing glass or ISFET sensors by temperature, fluoride content and pressure, with these requirements in view: Ex certification and GMP traceability of records.
Results
Since start-up the system has run steadily; the practical result is tighter dosing control and lower reagent consumption.
Power & Energy · PH — Application Case
Project Overview
The site is boiler feedwater, turbine condensate and FGD/DeNOx systems. The customer wanted PH properly configured on the existing plant, with the aim of continuous pH monitoring for neutralisation and compliance control.
Technical Challenges
What actually causes trouble is high temperature and pressure with both steam and saline water, and drift under high temperature and pressure, with very costly unplanned outages. All of this means the PH configuration has to involve choosing glass or ISFET sensors by temperature, fluoride content and pressure.
Configuration
Supply and installation were organised through the analyser range: selecting as part of a complete water-analysis system. On site this meant choosing glass or ISFET sensors by temperature, fluoride content and pressure, checked line by line against: compliance with power-industry codes and unit availability targets.
Performance
After commissioning the outcome is tighter dosing control and lower reagent consumption, and the readings are now used for process tuning.
Related Products
Endress+HauserOrbisint CPS11D Memosens
Endress+HauserLiquisys M CPM223
Endress+HauserMemosens CPS11E
Endress+HauserOrbipac CPF81
Endress+HauserMeas. cable CYK10 Memosens
Endress+HauserLiquisys M CPM253
Endress+HauserCeragel CPS71D Memosens
Endress+Hauser