Instrumentation · Engineering · Package · PLC
0755-82221901 sales@ainstru.com

CPS62E Digital ORP sensor

CPS62E  Digital ORP sensor
Memosens CPS62E
Configurable Models 2 models
Memosens 2.0 ORP electrode for the chemical and life sciences industries
Compare

ORP / Redox

Measuring Principle Sensor ORP / Redox
Application Hygiene and sterile applications (sterilizable, autoclavable):
• Fermenter
• Biotechnology
• Pharma
Characteristic Digital ORP electrode for hygienic production processes with ion trap
for long-term stable reference
Measuring range –1 500 to 1 500 mV
Measuring principle Gel compact electrode with ceramic junction and ion trap
Measuring element platinum cap
Design All shaft lengths with temperature sensor
Advanced gel technology
Material Sensor shaft: Glass to suit process
Metal lead: Ag/AgCl
Open aperture: Ceramic junction,
zirconium dioxide
ORP measuring element: Platinum
O-ring: FKM
Process coupling: PPS fiber-glass reinforced
Nameplate: Ceramic metal oxide
Dimension Diameter: 12 mm (0.46 inch)
Shaft lengths: 120, 225 and 360 mm
(4.68, 8.77 and 14.04 inch)
Process temperature 0 to 100 °C (32 to 212 °F)
0 to 140 °C (32 to 284 °F) (140 °C (284 °F) or sterilization only)
Process pressure 0.8 to 14 bar (11.6 to 203.1 psi) absolute
Temperature sensor NTC 30k
Ex certification With ATEX, IECEx, CSA C/US, NEPSI, Japan Ex and INMETRO approvals for use in
hazardous areas Zone 0, Zone 1 and Zone 2
Connection Inductive, digital connection head with Memosens 2.0 technology
Ingress protection IP68

Field of application
Memosens CPS62E is the digital specialist for demanding processes and hygienic applications. Its contamination-resistant gel guarantees stable measurement even in flowing media, in low conductivities and at high temperatures. Thanks to Memosens 2.0 digital technology, CPS62E combines maximum process integrity with simple operation. It resists moisture and enables lab calibration. It offers extended storage of calibration and process data providing the perfect basis for predictive maintenance.
Process technology and monitoring of processes with:
- Quickly changing ORP values
- High proportion of electrode poisons such as H2S
Chemical processes
Hygienic and sterile applications:
- Fermenters
- Biotechnology
- Life sciences
With ATEX, IECEx, CSA C/US, NEPSI, Japan, INMETRO approvals for use in hazardous areas, zones 0, 1 and 2.

Benefits
Memosens 2.0 offers extended storage of calibration and process data, enabling better trend identification and providing a future-proof basis for predictive maintenance and enhanced IIoT services.
Sensor resists strong acids and bases and high organic loads.
Maintains high accuracy even after CIP/SIP or autoclaving.
Free from animal-based materials and from acrylamide.
Upside-down mounting option allows for flexible installation.
Maximum process safety is ensured by non-contact, inductive signal transmission.
Minimized process downtime and extended sensor lifetime result in reduced operating costs.

 

ORP / Redox:

Measuring Principle Sensor ORP / Redox
Application Hygiene and sterile applications (sterilizable, autoclavable):
• Fermenter
• Biotechnology
• Pharma
 
Characteristic Digital ORP electrode for hygienic production processes with ion trap for long-term stable reference
Measuring range –1 500 to 1 500 mV
Measuring principle Gel compact electrode with ceramic junction and ion trap
Measuring element platinum cap
Design All shaft lengths with temperature sensor
Advanced gel technology
 
Material Sensor shaft: Glass to suit process
Metal lead: Ag/AgCl
Open aperture: Ceramic junction, zirconium dioxide
ORP measuring element: Platinum
O-ring: FKM
Process coupling: PPS fiber-glass reinforced
Nameplate: Ceramic metal oxide
 
Dimension Diameter: 12 mm (0.46 inch)
Shaft lengths: 120, 225 and 360 mm
(4.68, 8.77 and 14.04 inch)
Process temperature 0 to 100 °C (32 to 212 °F)
0 to 140 °C (32 to 284 °F) (140 °C (284 °F) or sterilization only)
Process pressure 0.8 to 7 bar (11.6 to 101.5 psi) absolute
Temperature sensor NTC 30k
Ex certification With ATEX, IECEx, CSA C/US, NEPSI, Japan Ex and INMETRO approvals for use in hazardous areas Zone 0, Zone 1 and Zone 2
Connection Inductive, digital connection head with Memosens 2.0 technology
Ingress protection IP68

Measuring principle video

Click to play

Spare Parts & Accessories 5

5 spare parts · click to collapse
Order codeDescription
71038228*** sensorfor assignment of sensors to measuring loop. 100 sensor clips with printable labelsDetails
71038229*** cablefor assignment of Sensors to measuring loop. 50 cable labels with printable labels.Details
71538217CPSxx electrode protection cap20 pc protective caps for pH sensors CPSxxDetails
CPY4-KCl electrolyte CPY4For liquid filled electrodesEnquire
CPY3-ORP calibration solution CPY3TechnicalEnquire

Configurator / Comparison

ConfigureEnter a product model to configure
CompareEnter the product models to compare — up to three products
2 models · click to collapse
All documents for this model
4 documents · click to expand
BA

BA pH电极CPSx1E, CPFx1E ORP电极CPSx2E, CPFx2E Chinese

Rev. 0526 20 pages
Preview
BA

BA pH sensors CPSx1E, CPFx1E ORP sensors CPSx2E, CPFx2E English

Rev. 0526 20 pages
Preview
TI

TI Memosens CPS62E Chinese

Rev. 0225 12 pages
Preview
TI

TI Memosens CPS62E English

Rev. 0225 12 pages
Preview
Municipal Wastewater Treatment

Municipal Wastewater Treatment · ORP — Application Case

Project Overview

The site is the inlet, biological and outlet stages of a municipal plant. The customer wanted ORP properly configured on the existing plant, with the aim of measuring redox potential to control disinfection and oxidation.

Technical Challenges

What actually causes trouble is high solids and corrosive fractions, with large diurnal flow swings, and effluent parameters drift and probes foul with sludge and biofilm. All of this means the ORP configuration has to involve choosing fouling-resistant electrodes and reference systems by medium contamination.

Configuration

Supply and installation were organised through the analyser range: selecting as part of a complete water-analysis system. On site this meant choosing fouling-resistant electrodes and reference systems by medium contamination, checked line by line against: stable compliance with Grade 1A discharge limits and online data reporting.

Performance

After commissioning the outcome is oxidant dosing with a real basis, avoiding excess and residue, and the readings are now used for process tuning.

Food & Beverage

Food & Beverage · ORP — Application Case

Site Conditions

This is a Food & Beverage customer whose plant is at dosing, pasteurising, filling and CIP stages. The main task was measuring redox potential to control disinfection and oxidation.

The Problem

The difficulty lies in syrups, dairy and beverages that scale easily, under strict hygienic requirements; at the same time frequent cleaning demands instruments that withstand hot CIP/SIP caustic cycles. Specification therefore means choosing fouling-resistant electrodes and reference systems by medium contamination.

What We Did

We took a analyser range approach — selecting as part of a complete water-analysis system. Delivery was built around choosing fouling-resistant electrodes and reference systems by medium contamination, with point-by-point checks on: food-safety and hygienic design per 3-A / EHEDG.

Operating Outcome

In service the system performs as intended — oxidant dosing with a real basis, avoiding excess and residue, with routine maintenance falling noticeably.

Chemical & Pharmaceutical

Chemical & Pharmaceutical · ORP — Application Case

Application Context

reactors, metering vessels and finished-product tanks is a typical Chemical & Pharmaceutical duty. The project started from ORP, focusing on measuring redox potential to control disinfection and oxidation.

Process Constraints

corrosion plus Ex protection shortens instrument life and makes downtime costly, and highly corrosive media with solvents and crystallisation, partly in explosive atmospheres only amplify it. The ORP specification must therefore cover choosing fouling-resistant electrodes and reference systems by medium contamination.

Delivery Approach

Delivery was handled as the analyser range — selecting as part of a complete water-analysis system. Execution centred on choosing fouling-resistant electrodes and reference systems by medium contamination, together with Ex certification and GMP traceability of records.

Field Results

Operation shows the benefit clearly — oxidant dosing with a real basis, avoiding excess and residue, with confidence in this measuring point improving markedly.

Power & Energy

Power & Energy · ORP — Application Case

Customer Profile

The typical setting in Power & Energy is boiler feedwater, turbine condensate and FGD/DeNOx systems. The measuring point is ORP; the focus is measuring redox potential to control disinfection and oxidation.

Key Difficulties

Conditions are high temperature and pressure with both steam and saline water and, on top of that, drift under high temperature and pressure, with very costly unplanned outages, which a standard configuration cannot handle for long. The design therefore starts with choosing fouling-resistant electrodes and reference systems by medium contamination.

Implementation

The scope ran through the analyser range: selecting as part of a complete water-analysis system. Technically it hinges on choosing fouling-resistant electrodes and reference systems by medium contamination, and on these requirements: compliance with power-industry codes and unit availability targets.

Customer Benefit

In practice this means oxidant dosing with a real basis, avoiding excess and residue, which cut the workload on the site maintenance team.