Instrumentation · Engineering · Package · PLC
0755-82221901 sales@ainstru.com

CPS96E Memosens

CPS96E Memosens
Memosens CPS96E
Configurable Models 2 models
Memosens CPS96E is the specialist for media with a high content of suspended solids such as dispersions, precipitations or emulsions. The open aperture prevents fouling and ensures reliable simultaneous pH and ORP measurement. Thanks to Memosens 2.0 digital technology, CPS96E combines maximum process integrity with simple operation. It resists moisture, enables lab calibration and offers extended storage of calibration and process data providing the perfect basis for predictive maintenance.
Compare

ORP / Redox

Measuring Principle Sensor ORP / Redox
Application pH / ORP sensor for heavily contaminated media
and suspended solids
• Chemical processes
• Pulp and paper industry
• Flue gas cleaning
• Contaminated media:
• Solids
• Emulsions
• Precipitation reactions
Characteristic Gel pH/ORP electrode with open aperture and double gel reference with ion trap for chemical applications
Measuring range ORP: –1 500 to 1 500 mV
pH: 0 to 14
Measuring principle Pt-disc as additional ORP element
rH measurement and control of the reference impedance
Design All shaft lengths with temperature sensor
Advanced gel technology
Hydrolysis stable gel
Material Sensor shaft: Glass to suit process
pH membrane glass: Type B
Metal lead: Ag/AgCl
ORP measuring element: Platinum
O-ring: FKM
Process coupling: PPS fiber-glass reinforced
Nameplate: Ceramic metal oxide
Dimension Diameter: 12 mm (0.46 inch)
Shaft lengths: 120, 225, 360 and 425 mm
(4.68, 8.77, 14.04 and 16.57 inch)
Process temperature 0 to 110 °C (32 to 230 °F)
Process pressure 0.8 to 14 bar (11.6 to 203 psi) absolute
Temperature sensor NTC 30k
Ex certification With ATEX, IECEx, CSA C/US, NEPSI, Japan Ex and INMETRO approvals for use in
hazardous areas Zone 0, Zone 1 and Zone 2
Connection Inductive, digital connection head with Memosens 2.0 technology
Ingress protection IP68

pH

Measuring Principle Potentiometric
Application pH / ORP sensor for heavily contaminated media
and suspended solids
• Chemical processes
• Pulp and paper industry
• Flue gas cleaning
• Contaminated media:
• Solids
• Emulsions
• Precipitation reactions
Characteristic Gel pH/ORP electrode with open aperture and double gel reference with ion trap for chemical applications
Measuring range ORP: –1 500 to 1 500 mV
pH: 0 to 14
Measuring principle Pt-disc as additional ORP element
rH measurement and control of the reference impedance
Design All shaft lengths with temperature sensor
Advanced gel technology
Hydrolysis stable gel
Material Sensor shaft: Glass to suit process
pH membrane glass: Type B
Metal lead: Ag/AgCl
ORP measuring element: Platinum
O-ring: FKM
Process coupling: PPS fiber-glass reinforced
Nameplate: Ceramic metal oxide
Dimension Diameter: 12 mm (0.46 inch)
Shaft lengths: 120, 225, 360 and 425 mm
(4.68, 8.77, 14.04 and 16.57 inch)
Process temperature 0 to 110 °C (32 to 230 °F)
Process pressure 0.8 to 14 bar (11.6 to 203 psi) absolute
Temperature sensor NTC 30k
Ex certification With ATEX, IECEx, CSA C/US, NEPSI, Japan Ex and INMETRO approvals for use in
hazardous areas Zone 0, Zone 1 and Zone 2
Connection Inductive, digital connection head with Memosens 2.0 technology
Ingress protection IP68

The Memosens CPS96E is the measurement specialist for fibrous media or media with a high concentration of suspended solids (e.g. dispersions, precipitants, emulsions). The open-junction diaphragm design with no risk of contamination ensures reliable pH and ORP measurement. The CPS96E uses Memosens 2.0 digital technology with high process integrity and very simple operation. The waterproof, moisture-proof design allows laboratory sensor calibration and supports extended data storage for calibration and process parameters. It is the perfect basis for predictive maintenance.

Benefits
Memosens 2.0 supports an extended storage unit for calibration and process parameters, enabling better trend identification and providing the perfect basis for future predictive maintenance and improved IIoT services.

  • Simultaneous measurement of pH, ORP and rH values (in rH mode) provides rich process information and is a solid foundation for strict process control.

  • The additional platinum electrode continuously monitors the reference impedance, providing a reliable guarantee of electrode quality.

  • Filled with stable gel electrolyte and featuring a reference electrode with an ion trap, the electrode is robust and resistant to poisoning.

  • Measurement results are unaffected by pressure and temperature fluctuations: the open-junction diaphragm design effectively prevents adhesion to the lead.

  • Non-contact inductive signal transmission for high process safety.

  • Minimizes production downtime, extends electrode service life and reduces operating costs.

Applications
Chemical industry

Pulp and paper industry

Contaminated media and media containing suspended solids
: - dispersions
- precipitants
- emulsions

Approved by ATEX, IECEx, CSA C/US, NEPSI, JPN, INMETRO for use in explosion-protection zones 0, 1 and 2.

Spare Parts & Accessories 6

6 spare parts · click to collapse
Order codeDescription
71038228*** sensorfor assignment of sensors to measuring loop. 100 sensor clips with printable labelsDetails
71038229*** cablefor assignment of Sensors to measuring loop. 50 cable labels with printable labels.Details
71538217CPSxx electrode protection cap20 pc protective caps for pH sensors CPSxxDetails
CPY4-KCl electrolyte CPY4For liquid filled electrodesEnquire
CPY20-pH buffer solution CPY20pH quality buffer solution, referenced to primary reference material of PTB and standard reference material of NIST. With calibration certificate buffer solutionEnquire
CPY3-ORP calibration solution CPY3TechnicalEnquire

Configurator / Comparison

ConfigureEnter a product model to configure
CompareEnter the product models to compare — up to three products

 

 

 

 

Source: Endress+Hauserpublic information from the website

2 models · click to collapse
All documents for this model
4 documents · click to expand
BA

BA pH/ORP组合电极CPS16E、CPS76E和CPS96E Chinese

Rev. 0326 20 pages
Preview
BA

BA Combined pH/ORP sensors CPS16E, CPS76E and CPS96E English

Rev. 0326 20 pages
Preview
TI

TI Memosens CPS96E Chinese

Rev. 0225 12 pages
Preview
TI

TI Memosens CPS96E English

Rev. 0225 12 pages
Preview
Municipal Wastewater Treatment

Municipal Wastewater Treatment · PH — Application Case

Application Context

the inlet, biological and outlet stages of a municipal plant is a typical Municipal Wastewater Treatment duty. The project started from PH, focusing on continuous pH monitoring for neutralisation and compliance control.

Process Constraints

effluent parameters drift and probes foul with sludge and biofilm, and high solids and corrosive fractions, with large diurnal flow swings only amplify it. The PH specification must therefore cover choosing glass or ISFET sensors by temperature, fluoride content and pressure.

Delivery Approach

Delivery was handled as the analyser range — selecting as part of a complete water-analysis system. Execution centred on choosing glass or ISFET sensors by temperature, fluoride content and pressure, together with stable compliance with Grade 1A discharge limits and online data reporting.

Field Results

Operation shows the benefit clearly — tighter dosing control and lower reagent consumption, with confidence in this measuring point improving markedly.

Food & Beverage

Food & Beverage · PH — Application Case

Customer Profile

The typical setting in Food & Beverage is dosing, pasteurising, filling and CIP stages. The measuring point is PH; the focus is continuous pH monitoring for neutralisation and compliance control.

Key Difficulties

Conditions are syrups, dairy and beverages that scale easily, under strict hygienic requirements and, on top of that, frequent cleaning demands instruments that withstand hot CIP/SIP caustic cycles, which a standard configuration cannot handle for long. The design therefore starts with choosing glass or ISFET sensors by temperature, fluoride content and pressure.

Implementation

The scope ran through the analyser range: selecting as part of a complete water-analysis system. Technically it hinges on choosing glass or ISFET sensors by temperature, fluoride content and pressure, and on these requirements: food-safety and hygienic design per 3-A / EHEDG.

Customer Benefit

In practice this means tighter dosing control and lower reagent consumption, which cut the workload on the site maintenance team.

Chemical & Pharmaceutical

Chemical & Pharmaceutical · PH — Application Case

Project Background

The project covers reactors, metering vessels and finished-product tanks. The work centres on PH and the core task is continuous pH monitoring for neutralisation and compliance control.

Operating Challenges

The medium and duty are characterised by highly corrosive media with solvents and crystallisation, partly in explosive atmospheres, and corrosion plus Ex protection shortens instrument life and makes downtime costly. So PH cannot be specified generically — it calls for choosing glass or ISFET sensors by temperature, fluoride content and pressure.

Solution

The Ainstru engineering team worked through the analyser range: selecting as part of a complete water-analysis system. The configuration involves choosing glass or ISFET sensors by temperature, fluoride content and pressure, with these requirements in view: Ex certification and GMP traceability of records.

Results

Since start-up the system has run steadily; the practical result is tighter dosing control and lower reagent consumption.

Power & Energy

Power & Energy · PH — Application Case

Project Overview

The site is boiler feedwater, turbine condensate and FGD/DeNOx systems. The customer wanted PH properly configured on the existing plant, with the aim of continuous pH monitoring for neutralisation and compliance control.

Technical Challenges

What actually causes trouble is high temperature and pressure with both steam and saline water, and drift under high temperature and pressure, with very costly unplanned outages. All of this means the PH configuration has to involve choosing glass or ISFET sensors by temperature, fluoride content and pressure.

Configuration

Supply and installation were organised through the analyser range: selecting as part of a complete water-analysis system. On site this meant choosing glass or ISFET sensors by temperature, fluoride content and pressure, checked line by line against: compliance with power-industry codes and unit availability targets.

Performance

After commissioning the outcome is tighter dosing control and lower reagent consumption, and the readings are now used for process tuning.