Technical Data
CompareORP / Redox
| Measuring Principle | Sensor ORP / Redox |
| Application | pH / ORP sensor for heavily contaminated media and suspended solids • Chemical processes • Pulp and paper industry • Flue gas cleaning • Contaminated media: • Solids • Emulsions • Precipitation reactions |
| Characteristic | Gel pH/ORP electrode with open aperture and double gel reference with ion trap for chemical applications |
| Measuring range | ORP: –1 500 to 1 500 mV pH: 0 to 14 |
| Measuring principle | Pt-disc as additional ORP element rH measurement and control of the reference impedance |
| Design | All shaft lengths with temperature sensor Advanced gel technology Hydrolysis stable gel |
| Material | Sensor shaft: Glass to suit process pH membrane glass: Type B Metal lead: Ag/AgCl ORP measuring element: Platinum O-ring: FKM Process coupling: PPS fiber-glass reinforced Nameplate: Ceramic metal oxide |
| Dimension | Diameter: 12 mm (0.46 inch) Shaft lengths: 120, 225, 360 and 425 mm (4.68, 8.77, 14.04 and 16.57 inch) |
| Process temperature | 0 to 110 °C (32 to 230 °F) |
| Process pressure | 0.8 to 14 bar (11.6 to 203 psi) absolute |
| Temperature sensor | NTC 30k |
| Ex certification | With ATEX, IECEx, CSA C/US, NEPSI, Japan Ex and INMETRO approvals for use in hazardous areas Zone 0, Zone 1 and Zone 2 |
| Connection | Inductive, digital connection head with Memosens 2.0 technology |
| Ingress protection | IP68 |
pH
| Measuring Principle | Potentiometric |
| Application | pH / ORP sensor for heavily contaminated media and suspended solids • Chemical processes • Pulp and paper industry • Flue gas cleaning • Contaminated media: • Solids • Emulsions • Precipitation reactions |
| Characteristic | Gel pH/ORP electrode with open aperture and double gel reference with ion trap for chemical applications |
| Measuring range | ORP: –1 500 to 1 500 mV pH: 0 to 14 |
| Measuring principle | Pt-disc as additional ORP element rH measurement and control of the reference impedance |
| Design | All shaft lengths with temperature sensor Advanced gel technology Hydrolysis stable gel |
| Material | Sensor shaft: Glass to suit process pH membrane glass: Type B Metal lead: Ag/AgCl ORP measuring element: Platinum O-ring: FKM Process coupling: PPS fiber-glass reinforced Nameplate: Ceramic metal oxide |
| Dimension | Diameter: 12 mm (0.46 inch) Shaft lengths: 120, 225, 360 and 425 mm (4.68, 8.77, 14.04 and 16.57 inch) |
| Process temperature | 0 to 110 °C (32 to 230 °F) |
| Process pressure | 0.8 to 14 bar (11.6 to 203 psi) absolute |
| Temperature sensor | NTC 30k |
| Ex certification | With ATEX, IECEx, CSA C/US, NEPSI, Japan Ex and INMETRO approvals for use in hazardous areas Zone 0, Zone 1 and Zone 2 |
| Connection | Inductive, digital connection head with Memosens 2.0 technology |
| Ingress protection | IP68 |
The Memosens CPS96E is the measurement specialist for fibrous media or media with a high concentration of suspended solids (e.g. dispersions, precipitants, emulsions). The open-junction diaphragm design with no risk of contamination ensures reliable pH and ORP measurement. The CPS96E uses Memosens 2.0 digital technology with high process integrity and very simple operation. The waterproof, moisture-proof design allows laboratory sensor calibration and supports extended data storage for calibration and process parameters. It is the perfect basis for predictive maintenance.
Benefits
Memosens 2.0 supports an extended storage unit for calibration and process parameters, enabling better trend identification and providing the perfect basis for future predictive maintenance and improved IIoT services.
-
Simultaneous measurement of pH, ORP and rH values (in rH mode) provides rich process information and is a solid foundation for strict process control.
-
The additional platinum electrode continuously monitors the reference impedance, providing a reliable guarantee of electrode quality.
-
Filled with stable gel electrolyte and featuring a reference electrode with an ion trap, the electrode is robust and resistant to poisoning.
-
Measurement results are unaffected by pressure and temperature fluctuations: the open-junction diaphragm design effectively prevents adhesion to the lead.
-
Non-contact inductive signal transmission for high process safety.
-
Minimizes production downtime, extends electrode service life and reduces operating costs.
Applications
Chemical industry
Pulp and paper industry
Contaminated media and media containing suspended solids
: - dispersions
- precipitants
- emulsions
Approved by ATEX, IECEx, CSA C/US, NEPSI, JPN, INMETRO for use in explosion-protection zones 0, 1 and 2.
Spare Parts & Accessories 6
6 spare parts · click to collapse
| Order code | Description | |
|---|---|---|
| 71038228 | *** sensorfor assignment of sensors to measuring loop. 100 sensor clips with printable labels | Details |
| 71038229 | *** cablefor assignment of Sensors to measuring loop. 50 cable labels with printable labels. | Details |
| 71538217 | CPSxx electrode protection cap20 pc protective caps for pH sensors CPSxx | Details |
| CPY4- | KCl electrolyte CPY4For liquid filled electrodes | Enquire |
| CPY20- | pH buffer solution CPY20pH quality buffer solution, referenced to primary reference material of PTB and standard reference material of NIST. With calibration certificate buffer solution | Enquire |
| CPY3- | ORP calibration solution CPY3Technical | Enquire |
Configurator / Comparison
Source: Endress+Hauserpublic information from the website
Manuals & Documents 4
All documents for this modelCase Studies
Municipal Wastewater Treatment · PH — Application Case
Application Context
the inlet, biological and outlet stages of a municipal plant is a typical Municipal Wastewater Treatment duty. The project started from PH, focusing on continuous pH monitoring for neutralisation and compliance control.
Process Constraints
effluent parameters drift and probes foul with sludge and biofilm, and high solids and corrosive fractions, with large diurnal flow swings only amplify it. The PH specification must therefore cover choosing glass or ISFET sensors by temperature, fluoride content and pressure.
Delivery Approach
Delivery was handled as the analyser range — selecting as part of a complete water-analysis system. Execution centred on choosing glass or ISFET sensors by temperature, fluoride content and pressure, together with stable compliance with Grade 1A discharge limits and online data reporting.
Field Results
Operation shows the benefit clearly — tighter dosing control and lower reagent consumption, with confidence in this measuring point improving markedly.
Food & Beverage · PH — Application Case
Customer Profile
The typical setting in Food & Beverage is dosing, pasteurising, filling and CIP stages. The measuring point is PH; the focus is continuous pH monitoring for neutralisation and compliance control.
Key Difficulties
Conditions are syrups, dairy and beverages that scale easily, under strict hygienic requirements and, on top of that, frequent cleaning demands instruments that withstand hot CIP/SIP caustic cycles, which a standard configuration cannot handle for long. The design therefore starts with choosing glass or ISFET sensors by temperature, fluoride content and pressure.
Implementation
The scope ran through the analyser range: selecting as part of a complete water-analysis system. Technically it hinges on choosing glass or ISFET sensors by temperature, fluoride content and pressure, and on these requirements: food-safety and hygienic design per 3-A / EHEDG.
Customer Benefit
In practice this means tighter dosing control and lower reagent consumption, which cut the workload on the site maintenance team.
Chemical & Pharmaceutical · PH — Application Case
Project Background
The project covers reactors, metering vessels and finished-product tanks. The work centres on PH and the core task is continuous pH monitoring for neutralisation and compliance control.
Operating Challenges
The medium and duty are characterised by highly corrosive media with solvents and crystallisation, partly in explosive atmospheres, and corrosion plus Ex protection shortens instrument life and makes downtime costly. So PH cannot be specified generically — it calls for choosing glass or ISFET sensors by temperature, fluoride content and pressure.
Solution
The Ainstru engineering team worked through the analyser range: selecting as part of a complete water-analysis system. The configuration involves choosing glass or ISFET sensors by temperature, fluoride content and pressure, with these requirements in view: Ex certification and GMP traceability of records.
Results
Since start-up the system has run steadily; the practical result is tighter dosing control and lower reagent consumption.
Power & Energy · PH — Application Case
Project Overview
The site is boiler feedwater, turbine condensate and FGD/DeNOx systems. The customer wanted PH properly configured on the existing plant, with the aim of continuous pH monitoring for neutralisation and compliance control.
Technical Challenges
What actually causes trouble is high temperature and pressure with both steam and saline water, and drift under high temperature and pressure, with very costly unplanned outages. All of this means the PH configuration has to involve choosing glass or ISFET sensors by temperature, fluoride content and pressure.
Configuration
Supply and installation were organised through the analyser range: selecting as part of a complete water-analysis system. On site this meant choosing glass or ISFET sensors by temperature, fluoride content and pressure, checked line by line against: compliance with power-industry codes and unit availability targets.
Performance
After commissioning the outcome is tighter dosing control and lower reagent consumption, and the readings are now used for process tuning.
Related Products
Endress+HauserOrbisint CPS11D Memosens
Endress+HauserLiquisys M CPM223
Endress+HauserMemosens CPS11E
Endress+HauserOrbipac CPF81
Endress+HauserMeas. cable CYK10 Memosens
Endress+HauserLiquisys M CPM253
Endress+HauserCeragel CPS71D Memosens
Endress+Hauser