Instrumentation · Engineering · Package · PLC
0755-82221901 sales@ainstru.com

CYC25 Cleanfit Control

CYC25 Cleanfit Control
Cleanfit Control CYC25
Only a clean sensor delivers reliable measured values. Cleanfit Control CYC25 in combination with Liquiline CM44 and Chemoclean Plus enables automated, regular cleaning of sensors. It thus guarantees highly accurate measured values for more process safety. Cleanfit Control also reduces process downtime and minimizes maintenance effort since there is no need to remove the sensor for cleaning.
Compare

pH

Measuring Principle Potentiometric
Application Water and wastewater, paper, food and beverages, solids, primaries, power stations, utilities
Installation Complete automated cleaning system
Characteristic Fully automated cleaning system with weekly programmable cleaning and different security functions
Design Fully automated cleaning system in combination with Liquiline CM44x
Material Bottom part of housing: PC-FR
Cover: PC-FR
Housing seal: EPDM
Dimension 237 x 194 x 162 mm (l x h x w)
9.33 x 7.64 x 6.38 inch (l x h x w)
Process temperature Ambient temperature range: -10 to 45 °C (10 to 113 °F)
Input One channel system

Only a clean sensor can provide reliable measured values. The Cleanfit Control CYC25 is used together with the Liquiline CM44 and Chemoclean Plus for fully automatic, periodic sensor cleaning. It ensures highly accurate measurement and a safer process. The Cleanfit Control does not require sensor removal during cleaning, reducing process downtime and minimizing maintenance workload.

Benefits
High safety: inline cleaning without removing the electrode
Automatic removal of deposits from the electrode ensures highly accurate, reliable measured values
High suitability: periodic cleaning ensures a long electrode service life
Fully automatic electrode cleaning with low maintenance costs
Suitable for corrosive media: intermittent measurement extends sensor service life

Applications
The Cleanfit Control enables fully automatic cleaning of sensors installed in retractable holders. High sensor performance is thus maintained without interrupting the process. The Cleanfit Control is particularly suitable for the following industries:
Water & wastewater
Paper industry
Food & beverage
Power
Metallurgy, mineral processing and other demanding applications with solids

   

 

 

A

A

Source: Endress+Hauserpublic information from the website

Measuring principle video

Click to play

Spare Parts & Accessories 16

16 spare parts · click to collapse
Order codeDescription
71361237Sensor output terminalDetails
71292485CYC25 spare parts: guard with gasketDetails
71107454CM442/CM444/CM448 housing cover hinges, 10 pcsCM442/CM444/CM448Details
71292496CYC25 spare part: hose connectorDetails
71361241Kit CDC90 canister with pump/fittingsDetails
50090491Hose connectorfor porge chamber for CPA450Details
51502808Hose connectorHose connection set 1.4404, G 1/4"/DN12Details
51511591Hose Connection AssemblyHose connection set PVDF G 1/4"/D16Details
51511590Hose Connection AssemblyHose connection set 1.4404, G 1/4"/D16Details
71114631tube.Details
71390988Water filter kitDetails
71390990Water filter strainer element kitDetails
71390993Pressure reducer kit with manometerDetails
71597972Kit CYC25/CDC30 Hoses to AssemblyDetails
XPC0003-XPA871: Accessories for CPA871 bracketAccessories, spare parts and maintenance kits for retractable process assembly Cleanfit CPA871Enquire
XPC0001-CPA875 Maintenance KitAccessories, spare parts and maintenance kits for retractable process assembly Cleanfit CPA875 Content: All selectable spare parts, sealing sets incl. certificates and approvals as well as accessoriesEnquire

Configurator / Comparison

ConfigureEnter a product model to configure
CompareEnter the product models to compare — up to three products
All documents for this model
5 documents · click to expand
BA

Cleanfit Control CYC25 Operating Instructions English

Rev. 0316 36 pages
Preview
TI

技术资料 Cleanfit Control CYC25 Chinese

Rev. 0315 16 pages
Preview
TI

Liquiline Control CDC30 Chinese

Rev. 0122 12 pages
Preview
TI

Cleanfit Control CYC25 Technical Information English

Rev. 0416 20 pages
Preview
TI

Liquiline Control CDC30 English

Rev. 0122 12 pages
Preview
Municipal Wastewater Treatment

Municipal Wastewater Treatment · PH — Application Case

Application Context

the inlet, biological and outlet stages of a municipal plant is a typical Municipal Wastewater Treatment duty. The project started from PH, focusing on continuous pH monitoring for neutralisation and compliance control.

Process Constraints

effluent parameters drift and probes foul with sludge and biofilm, and high solids and corrosive fractions, with large diurnal flow swings only amplify it. The PH specification must therefore cover choosing glass or ISFET sensors by temperature, fluoride content and pressure.

Delivery Approach

Delivery was handled as the analyser range — selecting as part of a complete water-analysis system. Execution centred on choosing glass or ISFET sensors by temperature, fluoride content and pressure, together with stable compliance with Grade 1A discharge limits and online data reporting.

Field Results

Operation shows the benefit clearly — tighter dosing control and lower reagent consumption, with confidence in this measuring point improving markedly.

Food & Beverage

Food & Beverage · PH — Application Case

Customer Profile

The typical setting in Food & Beverage is dosing, pasteurising, filling and CIP stages. The measuring point is PH; the focus is continuous pH monitoring for neutralisation and compliance control.

Key Difficulties

Conditions are syrups, dairy and beverages that scale easily, under strict hygienic requirements and, on top of that, frequent cleaning demands instruments that withstand hot CIP/SIP caustic cycles, which a standard configuration cannot handle for long. The design therefore starts with choosing glass or ISFET sensors by temperature, fluoride content and pressure.

Implementation

The scope ran through the analyser range: selecting as part of a complete water-analysis system. Technically it hinges on choosing glass or ISFET sensors by temperature, fluoride content and pressure, and on these requirements: food-safety and hygienic design per 3-A / EHEDG.

Customer Benefit

In practice this means tighter dosing control and lower reagent consumption, which cut the workload on the site maintenance team.

Chemical & Pharmaceutical

Chemical & Pharmaceutical · PH — Application Case

Project Background

The project covers reactors, metering vessels and finished-product tanks. The work centres on PH and the core task is continuous pH monitoring for neutralisation and compliance control.

Operating Challenges

The medium and duty are characterised by highly corrosive media with solvents and crystallisation, partly in explosive atmospheres, and corrosion plus Ex protection shortens instrument life and makes downtime costly. So PH cannot be specified generically — it calls for choosing glass or ISFET sensors by temperature, fluoride content and pressure.

Solution

The Ainstru engineering team worked through the analyser range: selecting as part of a complete water-analysis system. The configuration involves choosing glass or ISFET sensors by temperature, fluoride content and pressure, with these requirements in view: Ex certification and GMP traceability of records.

Results

Since start-up the system has run steadily; the practical result is tighter dosing control and lower reagent consumption.

Power & Energy

Power & Energy · PH — Application Case

Project Overview

The site is boiler feedwater, turbine condensate and FGD/DeNOx systems. The customer wanted PH properly configured on the existing plant, with the aim of continuous pH monitoring for neutralisation and compliance control.

Technical Challenges

What actually causes trouble is high temperature and pressure with both steam and saline water, and drift under high temperature and pressure, with very costly unplanned outages. All of this means the PH configuration has to involve choosing glass or ISFET sensors by temperature, fluoride content and pressure.

Configuration

Supply and installation were organised through the analyser range: selecting as part of a complete water-analysis system. On site this meant choosing glass or ISFET sensors by temperature, fluoride content and pressure, checked line by line against: compliance with power-industry codes and unit availability targets.

Performance

After commissioning the outcome is tighter dosing control and lower reagent consumption, and the readings are now used for process tuning.