Instrumentation · Engineering · Package · PLC
0755-82221901 sales@ainstru.com

FMB51 static pressure level gauge

FMB51 static pressure level gauge
Deltapilot M FMB51
Configurable Models 2 models
The pressure sensor uses CONTITE components for static pressure level measurement
Compare

Continuous / Liquids

Measuring Principle Hydrostatic
Characteristic / Application Pressure transmitter for hydrostatic level measurement with flush mounted metallic Contite measuring cell:
Hermetically sealed, condensate-resistant and climatic-proofed
Rod version
Specialities Modularity to differential pressure and process pressure devices (replacable display, universal electronics)
diagnostic functions
Hermetically sealed Contite measuring cell (condensate-resistant and climatic-proofed)
Supply / Communication 4...20mA HART:
10,5...45V DC
Ex ia: 10,5...30V DC
PROFIBUS PA /
FOUNDATION Fieldbus:
9...32V DC (Non Ex)
Accuracy Standard 0.2%
Optional 0.1%
Long term stability 0.05 % of URL/ year
Ambient temperature -40°C...85°C
(-40°F...185°F)
Process temperature -10°C...85°C
(14°F…212°F)
Process pressure / max. overpressure limit 40 bar (600 psi)
Pressure measuring range 100 mbar...10 bar
(1.5 psi...150 psi)
Main wetted parts Alloy C
316L
optional coating AuPt
Process connection Thread:
G1 1/2, MNPT1 1/2
Flange:
DN40...DN100,
ASME 2"...4",
JIS 10K
Max. measurement distance 100m (328ft) H2O
Communication 4...20 mA HART
PROFIBUS PA
FOUNDATION Fieldbus
Certificates / Approvals ATEX, FM, CSA, CSA C/US, IEC Ex, INMETRO, NEPSI
Safety approvals Overfill protection WHG
SIL
Design approvals EN 10204-3.1
NACE MR0175
Drinking water approvals KTW/ NSF
Options Separate housing
Initial device settings
Overvoltage protection
Application limits If pressurized, usage of two pressure transmitters to measure the differential pressure (electronic dP)
Observe ratio head pressure : hydrostatic pressure

Pressure

Measuring Principle Hydrostatic pressure
Characteristic Pressure transmitter for hydrostatic level measurement with flush mounted metallic Contite measuring cell:
Hermetically sealed, condensate-resistant, climatic-proofed and with lowest temperature influences
Rod version
Supply voltage 4...20 mA HART
10,5...45 VDC (Non Ex):
Ex ia: 10,5...30 VDC
PROFIBUS PA:
9...32 VDC (Non Ex)
FOUNDATION Fieldbus:
9...32 VDC (Non Ex)
Reference Accuracy Standard 0.2 %
Optional 0.1 %
Long term stability 0.05 % of URL/year
Process temperature -10°C...85°C
(14°F…212°F)
Ambient temperature -40°C...85°C
(-40°F...185°F)
Measuring cell 100 mbar...10 bar
(1.5 psi...150 psi)
Smallest calibratable span 10 mbar (1.45 psi)
Vacuum resistance 0 mbar abs.
Max. Turn down 100:1
Max. overpressure limit 40 bar (600 psi)
Process connection Thread:
G1 1/2, MNPT1 1/2
Flange:
DN40...DN100,
ASME 2"...4",
JIS 10K
Material process membrane 316L, AlloyC
Gold-Rhodium
Material gasket Viton, EPDM, Kalrez, none
Fill fluid Inert oil,
Synthetic oil
Material housing 316L, Die-cast aluminum
Communication 4...20 mA HART
PROFIBUS PA
FOUNDATION Fieldbus
Certificates / Approvals ATEX, FM, CSA, CSA C/US, IEC Ex, INMETRO, NEPSI, UK Ex
Safety approvals Overfill protection WHG
SIL
Design approvals EN10204-3.1
NACE MR0175
Drinking water approvals KTW/ NSF
Specialities Modularity to differential pressure and process pressure devices (replacable display, universal electronics)
Diagnostic functions

The Deltapilot FMB51 rod sensor uses the CONTITE measuring cell with a fixed process connection and is mainly used in the environmental sector to measure the level of liquid or paste-like media in open or closed vessels, with measurement unaffected by foam. The design complies with IEC 61508 and meets SIL2 functional safety requirements.

 

Advantages

Excellent repeatability and long-term stability

Turndown ratio: 100:1

Fully sealed CONTITE measuring cell: condensation-resistant, weather-protected; high reference accuracy: ±0.2%, optional: ±0.1%; minimal temperature influence

Point-to-point modules for measuring differential pressure, static pressure and pressure (Deltabar M - Deltapilot M - Cerabar M), e.g. replaceable display, universal electronics

Simple commissioning without operating tools

 

Areas of application

Hydrostatic sensors can be used for the following measurements:

 

Hydrostatic measurement of liquid and paste-like media in the process industry, process measurement, pharmaceutical and food industries

Measurement of liquid level, volume or mass

Spare Parts & Accessories 39

39 spare parts · click to collapse
Order codeDescription
71111056Atmospheric compensation filter portConsists of: Vent screw 304. Pressure compensation filter. O-ring EPDM, protection lid. Usage: FMB50, FMB51, FMB52, FMB53, FMD71, FMD72, FMD76, FMD77, FMD78, FMR60B, FMR62B, FMR63B, FMR66B, FMR67B, PMC51, PMC71, PMD70, PMD75, PMP71, PMP75, PMP51, PMP55.Details
71219639Atmospheric compensation filter portConsists of: vent screw 304. Pressure compensation filter. O-ring VMQ, protection lid. Usage: housing T17, FMB70, FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/ PMP75. Housing F15 at B1,BB,BD,BF,GA,ID,I1, FMB50/FMB51/FMB52/FMB53, PMC51, PMP51/PMP55.Details
52027000Stainless Steel CoverGasket 67,5x2,9x1,5 VMQ/PTFE Stainless steel housing F15Details
52027002Window cover with gasketSight glass: glass Gasket 67,5x2,9x1,5 VMQ/PTFE Stainless steel housing F15Details
52028207Window cover with gasketSight glass: Polycarbonat PC Gasket 67,5x2,9x1,5 VMQ/PTFE for use in non-hazardous area (EEx ia) Stainless steel housing F15Details
52028267Stainless steel cover with windowSight glass: Glass Claw for cover Gasket 67,5x2,9x1,5 VMQ/PTFE for dust Ex version Stainless steel housing F15 Cerabar MDetails
52028268Stainless Steel CoverClaw for cover Gasket 67,5x2,9x1,5 VMQ/PTFE Stainless steel housing F15 Cerabar MDetails
71092705Aluminum coverMaterial: aluminium. O-ring: EPDM. Not for Ex d/XP. Usage: FMB50/FMB51/FMB52/FMB53, FTC260/FTC262, PMC51, PMD55, PMP51/PMP55.Details
71092707Aluminum coverMaterial: aluminium. Sight glass: mineral glass. O-ring: EPDM. Not for Ex d/XP. Usage: FMB50/FMB51/FMB52/FMB53, FTC260/FTC262, PMC51, PMD55, PMP51/PMP55.Details
52020429Seal ring assemblyconsists of: 5x O-ring 75,87x2.62, EPDM, PTFE, FDADetails
52028179gasketProfile gasket for cover Stainless steel housing F15Details
52002449cable glandconsists of: cable gland M20 gasket NBR plug Pg13.5 Cerabar MDetails
52005984plug connectorwith gasket for Aluminium and stainless steel housingDetails
52020763plug connectorCerabar S PMC71, PMP71/PMP75 Deltabar S PMD70/PMD75,FMD76/FMD77/FMD78 Deltapilot S FMB70Details
52020762plug connectorHarting plug set Cerabar S PMC71, PMP71/PMP75 Deltabar S PMD70/PMD75,FMD76/FMD77/FMD78 Deltapilot S FMB70Details
71092709cable glandConsists of: cable gland M20, synthetic. O-ring 17.0x2.0 EPDM + PTFE/FDA. Usage: housing F30/31, FMB50/FMB51/FMB52/FMB53, PMC51, PMD55, PMP51/PMP55.Details
71092711cable glandConsists of: cable gland M20, metal. O-ring 17.0x2.0 EPDM + PTFE/FDA. Usage: housing F15/F31, FMB50/FMB51/FMB52/FMB53, PMC51, PMP51/PMP55, housing F30 PMD55.Details
71092712cable entryConsists of: gasket 18.72x2.51 NBR 70. Adapter M20 > G1/2. Not for Ex d. Usage: FMB50/FMB51/FMB52/FMB53, PMC51, PMD55, PMP51/PMP55.Details
71120017plug valve connectorConsists of: plug, seal, screw. Usage: FMB50/FMB51/FMB52/FMB53, PMC51, PMD55, PMP51/PMP55.Details
71290825Grounding terminalConsists of: spring washer, screw, earth handle, clamp. Usage: housing T14/T15/T17, FMB70, FMD71/FMD72/ FMD77/FMD78, PMC71, PMP71/PMP75, PMD70/PMD75. Housing F30/F31, FMB50/FMB51/FMB52/ FMB53, PMC51, PMD55, PMP51/PMP55.Details

Configurator / Comparison

ConfigureEnter a product model to configure
CompareEnter the product models to compare — up to three products

   

   

 

 

Source:Endress+Hauserwebsite public information

Measuring principle video

Click to play
2 models · click to collapse
All documents for this model
11 documents · click to expand
BA

Cerabar M, Deltabar M, Deltapilot M HART (V 01.00.zz) Chinese

HART Rev. 2122 140 pages
Preview
BA

操作手册 Cerabar M PMC51, PMP51, PMP55 Deltabar M PMD55 Deltapilot M FMB50/51/52/53 Chinese

Rev. 1712 132 pages
Preview
BA

Cerabar M / Deltabar M / Deltapilot M, Operating Instructions FOUNDATION Fieldbus Chinese

FOUNDATION-Fieldbus Rev. 0922 224 pages
Preview
BA

Cerabar M /Deltabar M /Deltapilot M Operating Instructions PROFIBUS PA Chinese

PROFIBUS-PA Rev. 0922 208 pages
Preview
BA

Cerabar M, Deltabar M, Deltapilot M HART (V 01.00.zz) English

HART Rev. 2122 140 pages
Preview
BA

Cerabar M / Deltabar M / Deltapilot M, Operating Instructions FOUNDATION Fieldbus English

FOUNDATION-Fieldbus Rev. 0922 224 pages
Preview
BA

Cerabar M /Deltabar M /Deltapilot M Operating Instructions PROFIBUS PA English

PROFIBUS-PA Rev. 0922 208 pages
Preview
TI

TI 焊接接头、过程转接头和法兰 Chinese

Rev. 2726 130 pages
Preview
TI

TI Deltapilot M FMB50, FMB51, FMB52, FMB53 Chinese

Rev. 2424 72 pages
Preview
TI

TI Weld-in adapter, process adapter and flanges English

Rev. 2726 132 pages
Preview
TI

TI Deltapilot M FMB50, FMB51, FMB52, FMB53 English

Rev. 2526 76 pages
Preview
Municipal Wastewater Treatment

Municipal Wastewater Treatment · Static Pressure Measurement — Application Case

Project Background

The project covers the inlet, biological and outlet stages of a municipal plant. The work centres on Static Pressure Measurement and the core task is inferring vessel level or density from hydrostatic pressure.

Operating Challenges

The medium and duty are characterised by high solids and corrosive fractions, with large diurnal flow swings, and effluent parameters drift and probes foul with sludge and biofilm. So Static Pressure Measurement cannot be specified generically — it calls for choosing range by tank height, density and pressurisation.

Solution

The Ainstru engineering team worked through the pressure range: pressure solution matched to process pressure and temperature. The configuration involves choosing range by tank height, density and pressurisation, with these requirements in view: stable compliance with Grade 1A discharge limits and online data reporting.

Results

Since start-up the system has run steadily; the practical result is submersible mounting that avoids civil works in pit and sump retrofits.

Food & Beverage

Food & Beverage · Static Pressure Measurement — Application Case

Project Overview

The site is dosing, pasteurising, filling and CIP stages. The customer wanted Static Pressure Measurement properly configured on the existing plant, with the aim of inferring vessel level or density from hydrostatic pressure.

Technical Challenges

What actually causes trouble is syrups, dairy and beverages that scale easily, under strict hygienic requirements, and frequent cleaning demands instruments that withstand hot CIP/SIP caustic cycles. All of this means the Static Pressure Measurement configuration has to involve choosing range by tank height, density and pressurisation.

Configuration

Supply and installation were organised through the pressure range: pressure solution matched to process pressure and temperature. On site this meant choosing range by tank height, density and pressurisation, checked line by line against: food-safety and hygienic design per 3-A / EHEDG.

Performance

After commissioning the outcome is submersible mounting that avoids civil works in pit and sump retrofits, and the readings are now used for process tuning.

Chemical & Pharmaceutical

Chemical & Pharmaceutical · Static Pressure Measurement — Application Case

Site Conditions

This is a Chemical & Pharmaceutical customer whose plant is at reactors, metering vessels and finished-product tanks. The main task was inferring vessel level or density from hydrostatic pressure.

The Problem

The difficulty lies in highly corrosive media with solvents and crystallisation, partly in explosive atmospheres; at the same time corrosion plus Ex protection shortens instrument life and makes downtime costly. Specification therefore means choosing range by tank height, density and pressurisation.

What We Did

We took a pressure range approach — pressure solution matched to process pressure and temperature. Delivery was built around choosing range by tank height, density and pressurisation, with point-by-point checks on: Ex certification and GMP traceability of records.

Operating Outcome

In service the system performs as intended — submersible mounting that avoids civil works in pit and sump retrofits, with routine maintenance falling noticeably.

Power & Energy

Power & Energy · Static Pressure Measurement — Application Case

Application Context

boiler feedwater, turbine condensate and FGD/DeNOx systems is a typical Power & Energy duty. The project started from Static Pressure Measurement, focusing on inferring vessel level or density from hydrostatic pressure.

Process Constraints

drift under high temperature and pressure, with very costly unplanned outages, and high temperature and pressure with both steam and saline water only amplify it. The Static Pressure Measurement specification must therefore cover choosing range by tank height, density and pressurisation.

Delivery Approach

Delivery was handled as the pressure range — pressure solution matched to process pressure and temperature. Execution centred on choosing range by tank height, density and pressurisation, together with compliance with power-industry codes and unit availability targets.

Field Results

Operation shows the benefit clearly — submersible mounting that avoids civil works in pit and sump retrofits, with confidence in this measuring point improving markedly.