Instrumentation · Engineering · Package · PLC
0755-82221901 sales@ainstru.com

FTL51B-1M71/0

FTL51B-1M71/0
Product family: Tuning fork level switch
Tuning fork level switchIn Stock (6)
Endress+Hauser FTL51B-1M71/0
Tuning fork level switch;Approval Non-hazardous area;Output FEL64, relay DPDT 19-253VAC/19-55VDC contact 253V/6A + test button;Display/Operation W/o; switch;Housing/Material Single compartment; Alu, coated;Electrical Connection Gland M20, plastic, IP66/68 NEMA Type 4X/6P;Application Process max 150oC/302oF, max 64bar;Surface Refinement Standard Ra<3,2µm/126µin;Type Of Probe Compact version;Sensor Length/Material Compact version; 316L;Process Connection, Sealing Surface Thread

Order Code:FTL51B-1M71/0

Corresponding ext. order code:FTL51B-AAA4ABAAA1AJI1VBJ

Name:Tuning fork level switch

Configuration

CodeNameOrderSpecification
010ApprovalAANon-hazardous area
020OutputA4FEL64, relay DPDT 19-253VAC/19-55VDC contact 253V/6A + test button
030Display; OperationAW/o; switch
040Housing; MaterialBSingle compartment; Alu, coated
050Electrical ConnectionAGland M20, plastic, IP66/68 NEMA Type 4X/6P
060ApplicationAProcess max 150oC/302oF, max 64bar
080Surface RefinementAStandard Ra<3,2µm/126µin
085Type Of Probe1Compact version
090Sensor Length; MaterialAJCompact version; 316L
105Process Connection, Sealing SurfaceI1Thread ISO228, G
110Process ConnectionVBJ3/4", 316L

Configuration Explained

This is an FTL51B vibrating level switch, for non-hazardous areas, FEL64 relay output, DPDT, 19 to 253 VAC or 19 to 55 VDC, contact 6 A with test button, without display, aluminium single-chamber housing, AC/DC universal, well matched measuring range, easy selection on site, good stability with low drift, trouble-free on site and easy to maintain later, suitable for level alarm in water treatment and chemical tanks.

26 models · click to collapse