Instrumentation · Engineering · Package · PLC
0755-82221901 sales@ainstru.com

FTL825 Nivotester

FTL825 Nivotester
Nivotester FTL825
The Nivotester FTL825 supplies the Liquiphant FailSafe FTL8x point level switch with direct voltage via a two-wire cable. At the same time, it analyzes the current values (4-20mA discrete) of the Liquiphant and returns a switching signal. The signal inputs of the Nivotester FTL825 are galvanically isolated from the mains and the output and can be ordered Safety-critical systems up to SIL3. For industries where redundant or diverse systems are either not recommended or not possible.
Compare

Point Level / Liquids

Measuring Principle Vibration Liquids
Characteristic / Application FailSafe level transmitter point level.
Top hat rail mounting
Connection to FTL80/81/85
Permanent self-monitoring,LIVE-Signal.
Specialities SIL 3 according to IEC61508.
Supply / Communication 85 - 253 VAC/DC
20 - 30 VAC/20-60VDC
Ambient temperature –20 to +60 °C
(–4 to +140 °F)
Communication 2x SPST safety contact point level
1x SPST signal contact
1X SPDT fault contact
Certificates / Approvals ATEX, FM, CSA, CSA C/US, IEC Ex, NEPSI
Safety approvals Overfill protection WHG
Leakage Detection
Marine approval GL/ ABS/ LR/ BV/ DNV

The Nivotester FTL825 directly powers the Liquiphant fail-safe FTL8x vibronic level switch via a two-core cable, while analyzing the Liquiphant current value (independent 4-20 mA) and returning the switch signal. The input signal of the Nivotester FTL825 is electrically isolated from the output and the power supply; the system functional safety reaches SIL3, and redundant or diverse systems are not recommended or cannot be used.

Benefits
SIL3 functional safety features: internal dual-channel design, permanent self-monitoring, online monitoring of the connection to the sensor, permanent monitoring of the Liquiphant fail-safe limit switch
LIVE signal permanently visualized
Advanced fault detection functions and error message display
Verification of the entire measuring system, including the control and signaling devices in the loop, via the verification test key or remote control
Integrated locking function (self-holding)
Four switch outputs (individually evaluable): two as level safety contacts in accordance with the quiescent-current principle for output signal redundancy; one signal contact (e.g. lamp), one fault-signal changeover contact
Proof test: proof test intervals of up to 12 years

Applications
Fail-safe limit detection switch, rail-mountable
Ambient temperature: -20 ~ +60°C (-4 ~ +140°F)
International explosion-protection approval, overflow protection WHG

 

Spare Parts & Accessories 2

2 spare parts · click to collapse
Order codeDescription
71185026fuseDesign 5x20. Consists of: 2x fuse 250V. 2x fuse holder. Usage: FTL825.Details
52010132Field housing带透明窗口的合成树脂防护外壳 防护等级 IP66 4x22.5mm or 2x45mmDetails

Configurator / Comparison

ConfigureEnter a product model to configure
CompareEnter the product models to compare — up to three products

   

   

 

 

Source: Endress+Hauserpublic information from the website

Measuring principle video

Click to play
All documents for this model
3 documents · click to expand
BA

Nivotester FailSafe FTL825 Operating Instructions English

Rev. 0111 32 pages
Preview
TI

技术资料 Nivotester FailSafe FTL825 Chinese

Rev. 0111 16 pages
Preview
TI

Nivotester FailSafe FTL825 Technical Information English

Rev. 0111 16 pages
Preview
Municipal Wastewater Treatment

Municipal Wastewater Treatment · tuning fork — Application Case

Site Conditions

This is a Municipal Wastewater Treatment customer whose plant is at the inlet, biological and outlet stages of a municipal plant. The main task was vibrating-fork point level detection and high/low alarms.

The Problem

The difficulty lies in high solids and corrosive fractions, with large diurnal flow swings; at the same time effluent parameters drift and probes foul with sludge and biofilm. Specification therefore means choosing fork length and surface finish by density and stickiness.

What We Did

We took a level range approach — level solution matched to the actual tank and silo geometry. Delivery was built around choosing fork length and surface finish by density and stickiness, with point-by-point checks on: stable compliance with Grade 1A discharge limits and online data reporting.

Operating Outcome

In service the system performs as intended — no calibration needed, with dependable switching, with routine maintenance falling noticeably.

Food & Beverage

Food & Beverage · tuning fork — Application Case

Application Context

dosing, pasteurising, filling and CIP stages is a typical Food & Beverage duty. The project started from tuning fork, focusing on vibrating-fork point level detection and high/low alarms.

Process Constraints

frequent cleaning demands instruments that withstand hot CIP/SIP caustic cycles, and syrups, dairy and beverages that scale easily, under strict hygienic requirements only amplify it. The tuning fork specification must therefore cover choosing fork length and surface finish by density and stickiness.

Delivery Approach

Delivery was handled as the level range — level solution matched to the actual tank and silo geometry. Execution centred on choosing fork length and surface finish by density and stickiness, together with food-safety and hygienic design per 3-A / EHEDG.

Field Results

Operation shows the benefit clearly — no calibration needed, with dependable switching, with confidence in this measuring point improving markedly.

Chemical & Pharmaceutical

Chemical & Pharmaceutical · tuning fork — Application Case

Customer Profile

The typical setting in Chemical & Pharmaceutical is reactors, metering vessels and finished-product tanks. The measuring point is tuning fork; the focus is vibrating-fork point level detection and high/low alarms.

Key Difficulties

Conditions are highly corrosive media with solvents and crystallisation, partly in explosive atmospheres and, on top of that, corrosion plus Ex protection shortens instrument life and makes downtime costly, which a standard configuration cannot handle for long. The design therefore starts with choosing fork length and surface finish by density and stickiness.

Implementation

The scope ran through the level range: level solution matched to the actual tank and silo geometry. Technically it hinges on choosing fork length and surface finish by density and stickiness, and on these requirements: Ex certification and GMP traceability of records.

Customer Benefit

In practice this means no calibration needed, with dependable switching, which cut the workload on the site maintenance team.

Power & Energy

Power & Energy · tuning fork — Application Case

Project Background

The project covers boiler feedwater, turbine condensate and FGD/DeNOx systems. The work centres on tuning fork and the core task is vibrating-fork point level detection and high/low alarms.

Operating Challenges

The medium and duty are characterised by high temperature and pressure with both steam and saline water, and drift under high temperature and pressure, with very costly unplanned outages. So tuning fork cannot be specified generically — it calls for choosing fork length and surface finish by density and stickiness.

Solution

The Ainstru engineering team worked through the level range: level solution matched to the actual tank and silo geometry. The configuration involves choosing fork length and surface finish by density and stickiness, with these requirements in view: compliance with power-industry codes and unit availability targets.

Results

Since start-up the system has run steadily; the practical result is no calibration needed, with dependable switching.