SWA70 WirelessHART Adapter

SWA70 WirelessHART Adapter

WirelessHART Adapter SWA70

The WirelessHART Adapter SWA70 is an interface module for the wireless transmission of 4 to 20 mA/HART signals from connected field devices to a WirelessHART Fieldgate. It is powered by either a battery pack or power supply units. The WirelessHART Adapter can be used in hazardous and non-hazardous area for applications.
Compare

Wireless components

Measuring Principle WirelessHART
Function Intelligent WirelessHART interface module for connection to 4...20 mA/HART devices
Certification Non-hazardous area
ATEX, CSA, IEC Ex, JPN Ex
Input One point-to-point with a HART device, or
One point-to-point connection with a 4...20 mA device, or
Up to four HART field devices connected in multidrop mode if a wide range power unit is used.
Output WirelessHART communication interface
Transmission rate: Nominal 250 kBits/s
Operating frequency: 2.4 GHz (ISM band)
Transmission range under reference conditions:
Outdoor 250 m, indoor 50 m
Auxiliary power supply / Loop power supply Special long live Lithium Thionylchloride battery pack
24-230V AC/DC external power
DC power unit
Dimensions (wxhxd) W x H x D: 111.5 mm x 189.9 mm x 92.8 mm
Dimensions in mm 25.4 mm = 1 inch
Software Internal software for controlling, powering, and reading from 4…20 mA/HART field devices
Operation Integral via Pushbutton, PC configuration via DTM and FieldCare or DD
Display Integral via 3 LEDs
Operating Voltage Special long live Lithium Thionylchloride battery pack
For versions with electronically regulated power supply:
Wide-range power supply: 24 V...230 V AC/DC ± 10%, 50/60 Hz
DC power unit: 8 V...50 V DC ± 10%
In the event of an external power supply failure, wireless communication is maintained for at least one hour by means of an internal supply.

The Endress+Hauser WirelessHART adapter SWA70 serves as an extension interface for HART and 4...20 mA devices, wirelessly connecting field instruments and the WirelessHART Fieldgate. It is powered by battery or an external power supply unit. The WirelessHART adapter can be used in hazardous and non-hazardous areas.

Benefits
Fast upgrade of HART devices to WirelessHART technology
Fast integration of 4...20 mA devices into the WirelessHART network
One adapter can connect one 4…20 mA loop or up to 4 HART devices (in multidrop mode)
Adapter and connected devices support burst mode and event notification
Connect distant, hard-to-access HART devices to the plant control room without laying expensive cables
Simple planning, easy installation and rapid integration

Application areas
Process optimization: connecting adapters makes monitoring and optimization of plant sections twice as effective.
Tank farm and silo monitoring: periodic transmission of measured values, device and battery status signals to higher-level systems.
Plant status monitoring: in plants, devices often cannot be connected to the control room due to accessibility or cabling costs. Wireless devices can then be added at critical points. Improved data flow and diagnostics increase plant reliability and safety.

   

   

 

 

Source: public information from the Endress+Hauser website

Measuring principle video

Click to play

Spare Parts & Accessories 8

8 spare parts · click to collapse
Order codeDescription
71092238SWA70 batteryApproval: ATEX, FM, CSA, IEC. Usage: SWA70.Details
71093078Mounting bracket SWA70Material: 304. Usage: SWA70.Details
71093795cable glandConsists of: Screwed cable gland M20, O-ring 17.0x2.0 EPDM. Usage: SWA70.Details
71093797Cable entry fitting M20, SWA70Consists of: Adapter M20 > M20, 316L, O-ring 17.0x2.0 EPDM. Usage: SWA70 at field device.Details
71093798Cable entry gland G1/2, SWA70Consists of: Adapter M20 > G1/2, 316L, O-ring 17.0x2.0 EPDM. Usage: SWA70 at field device.Details
71093799Cable entry gland NPT1/2, SWA70Consists of: Adapter M20 > N1/2, 316L, O-ring 17.0x2.0 EPDM. Usage: SWA70 at field device.Details
71093800Cable entry gland NPT3/4, SWA70Consists of: Adapter M20 > NPT3/4, 316L, O-ring 17.0x2.0 EPDM. Usage: SWA70 at field device.Details
SWA70-WirelessHART Adapter SWA70Application: process/inventory monitoring, plant asset management. Based on WirelessHART standard. Usage: wireless integration of field devices.Enquire

Configurator / Comparison

ConfigureEnter a product model to configure
CompareEnter the product models to compare — up to three products
All documents for this model
8 documents · click to expand
BA

BA WirelessHART适配器SWA70 Chinese

Rev. 2222 100 pages
Preview
BA

BA WirelessHART adapter SWA70 English

Rev. 2222 106 pages
Preview
BA

WirelessHART Adapter SWA70 Operating Instructions English

116 pages
Preview
BA

WirelessHART Adapter SWA70 Operating Instructions English

96 pages
Preview
BA

WirelessHART Adapter SWA70 Operating Instructions English

96 pages
Preview
TI

TI WirelessHART适配器SWA70 Chinese

Rev. 2524 24 pages
Preview
TI

TI WirelessHART adapter SWA70 English

Rev. 2524 24 pages
Preview
TI

WirelessHART Adapter SWA70 Technical Information English

12 pages
Preview
Municipal Wastewater Treatment

Municipal Wastewater Treatment · Gateways and modems — Application Case

Project Background

The project covers the inlet, biological and outlet stages of a municipal plant. The work centres on Gateways and modems and the core task is converting field data into remote transmission channels.

Operating Challenges

The medium and duty are characterised by high solids and corrosive fractions, with large diurnal flow swings, and effluent parameters drift and probes foul with sludge and biofilm. So Gateways and modems cannot be specified generically — it calls for configured by protocol, tag count and carrier network conditions.

Solution

The Ainstru engineering team worked through the system components range: supplying as a full cabinet and signal-chain configuration. The configuration involves configured by protocol, tag count and carrier network conditions, with these requirements in view: stable compliance with Grade 1A discharge limits and online data reporting.

Results

Since start-up the system has run steadily; the practical result is remote sites can report back, making unattended operation possible.

Food & Beverage

Food & Beverage · Gateways and modems — Application Case

Project Overview

The site is dosing, pasteurising, filling and CIP stages. The customer wanted Gateways and modems properly configured on the existing plant, with the aim of converting field data into remote transmission channels.

Technical Challenges

What actually causes trouble is syrups, dairy and beverages that scale easily, under strict hygienic requirements, and frequent cleaning demands instruments that withstand hot CIP/SIP caustic cycles. All of this means the Gateways and modems configuration has to involve configured by protocol, tag count and carrier network conditions.

Configuration

Supply and installation were organised through the system components range: supplying as a full cabinet and signal-chain configuration. On site this meant configured by protocol, tag count and carrier network conditions, checked line by line against: food-safety and hygienic design per 3-A / EHEDG.

Performance

After commissioning the outcome is remote sites can report back, making unattended operation possible, and the readings are now used for process tuning.

Chemical & Pharmaceutical

Chemical & Pharmaceutical · Gateways and modems — Application Case

Site Conditions

This is a Chemical & Pharmaceutical customer whose plant is at reactors, metering vessels and finished-product tanks. The main task was converting field data into remote transmission channels.

The Problem

The difficulty lies in highly corrosive media with solvents and crystallisation, partly in explosive atmospheres; at the same time corrosion plus Ex protection shortens instrument life and makes downtime costly. Specification therefore means configured by protocol, tag count and carrier network conditions.

What We Did

We took a system components range approach — supplying as a full cabinet and signal-chain configuration. Delivery was built around configured by protocol, tag count and carrier network conditions, with point-by-point checks on: Ex certification and GMP traceability of records.

Operating Outcome

In service the system performs as intended — remote sites can report back, making unattended operation possible, with routine maintenance falling noticeably.

Power & Energy

Power & Energy · Gateways and modems — Application Case

Application Context

boiler feedwater, turbine condensate and FGD/DeNOx systems is a typical Power & Energy duty. The project started from Gateways and modems, focusing on converting field data into remote transmission channels.

Process Constraints

drift under high temperature and pressure, with very costly unplanned outages, and high temperature and pressure with both steam and saline water only amplify it. The Gateways and modems specification must therefore cover configured by protocol, tag count and carrier network conditions.

Delivery Approach

Delivery was handled as the system components range — supplying as a full cabinet and signal-chain configuration. Execution centred on configured by protocol, tag count and carrier network conditions, together with compliance with power-industry codes and unit availability targets.

Field Results

Operation shows the benefit clearly — remote sites can report back, making unattended operation possible, with confidence in this measuring point improving markedly.