Instrumentation · Engineering · Package · PLC
0755-8222 1901 sales@ainstru.com

SWG70 无线HART网关

SWG70 无线HART网关

WirelessHART Fieldgate SWG70

Endress+Hauser's WirelessHART Fieldgate SWG70 has been designed to act as interface between a system using Ethernet or RS-485 physical layer and WirelessHART network. The gateway is designed for mounting in explosion hazardous areas Zone 2. An integral or remote antenna can be mounted according to the needs of the application.
Compare

Wireless components

Measuring Principle
Function Intelligent WirelessHART gateway with Ethernet and RS-485 interfaces
Certification Non-hazardous area, ATEX, IEC Ex
Input WirelessHART communication interface
Transmission rate: Nominal 250 kBits/s
Operating frequency: 2.4 GHz (ISM band)
Transmission range under reference conditions:
Outdoor 250 m, indoor 50 m
Output Ethernet (10 BASE-T/10 BASE TX)
- Configurable for HART IP and MODBUS TCP communication
RS-485 serial interface
- Configurable for HART Version 7.0 or MODBUS RTU communication
EtherNet/IP interface
Auxiliary power supply / Loop power supply 20 VDC to 30 VDC
Dimensions (wxhxd) W x H x D:
257 mm x 85 mm x 285 mm with cable glands and antenna
257 mm x 85 mm x 115 mm without cable glands and antenna
Software Internal software for controlling the WirelessHART network including web interface for configuration.
Operation Integral via Pushbuttons
PC configuration:
- Web browser via Ethernet
- FieldCare via Ethernet (HART IP CommDTM) or RS-485 (S-MUX DTM)
Display Integral via 5 LEDs
Operating Voltage 20 VDC to 30 VDC
Nominal current <5 W

The Endress+Hauser WirelessHART Fieldgate SWG70 is designed as an interface between systems using the Ethernet or RS-485 physical layer and the WirelessHART network. The gateway is designed for installation in Zone 2 hazardous areas, with an intrinsically safe antenna port. Internal or remote antennas can be installed according to application requirements.

Benefits
WirelessHART network with easy commissioning and self-organizing diagnostics
Seamless integration of field device information into higher-level systems via standardized protocols such as MODBUS, Ethernet, HART-IP or OPC
Wireless configuration and management of intelligent field devices using FieldCare
Flexible Fieldgate operation in hazardous areas of the plant

Application areas
Process optimization, tank and silo monitoring/inventory control, and equipment status monitoring. The WirelessHART gateway converts and stores wireless device data in a format compatible with other systems. With an Ethernet interface and serial port for connection to host applications such as plant asset management and SCADA tools.

   

Technical information

   

Technical data

 

 

Documents/Manuals/Software

 

 

Accessories/Spare parts

 

Source: public information from the Endress+Hauser website

Municipal Wastewater Treatment

Municipal Wastewater Treatment — Wastewater Treatment Plant · Gateways and Modems Application Case

Project Background

Municipal Wastewater Treatment customers at the Wastewater Treatment Plant stage have long faced the challenge of insufficient accuracy in effluent quality monitoring and instruments prone to contamination causing data drift, affecting compliance discharge, placing higher demands on the stability and measurement accuracy of Gateways and Modems.

Solution

Based on the on-site conditions, the Ainstru technical team selected suitable Gateways and Modems for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.

Results

  • Measurement accuracy and response speed significantly improved, with stable and reliable data;
  • Instruments adapt to complex Municipal Wastewater Treatment conditions, greatly reducing maintenance;
  • Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.
Food & Beverage

Food & Beverage — Food Production Line · Gateways and Modems Application Case

Project Background

Food & Beverage customers at the Food Production Line stage have long faced the challenge of high hygienic measurement requirements, with inline instruments needing to withstand CIP/SIP cleaning while maintaining stable accuracy, placing higher demands on the stability and measurement accuracy of Gateways and Modems.

Solution

Based on the on-site conditions, the Ainstru technical team selected suitable Gateways and Modems for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.

Results

  • Measurement accuracy and response speed significantly improved, with stable and reliable data;
  • Instruments adapt to complex Food & Beverage conditions, greatly reducing maintenance;
  • Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.
Chemical & Pharmaceutical

Chemical & Pharmaceutical — Reactors and Storage Tanks · Gateways and Modems Application Case

Project Background

Chemical & Pharmaceutical customers at the Reactors and Storage Tanks stage have long faced the challenge of highly corrosive media and complex conditions, requiring corrosion-resistant and explosion-proof instruments, placing higher demands on the stability and measurement accuracy of Gateways and Modems.

Solution

Based on the on-site conditions, the Ainstru technical team selected suitable Gateways and Modems for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.

Results

  • Measurement accuracy and response speed significantly improved, with stable and reliable data;
  • Instruments adapt to complex Chemical & Pharmaceutical conditions, greatly reducing maintenance;
  • Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.
Power & Energy

Power & Energy — Power Plant Boiler and Turbine · Gateways and Modems Application Case

Project Background

Power & Energy customers at the Power Plant Boiler and Turbine stage have long faced the challenge of unstable measurement under high temperature and pressure, with high maintenance and downtime costs, placing higher demands on the stability and measurement accuracy of Gateways and Modems.

Solution

Based on the on-site conditions, the Ainstru technical team selected suitable Gateways and Modems for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.

Results

  • Measurement accuracy and response speed significantly improved, with stable and reliable data;
  • Instruments adapt to complex Power & Energy conditions, greatly reducing maintenance;
  • Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.