Instrumentation · Engineering · Package · PLC
0755-82221901 sales@ainstru.com

PMC11 pressure transmitter

PMC11 pressure transmitter
Cerabar PMC11
Configurable Models 16 models
The economical pressure transmitter with ceramic diaphragm sensor is used for gas or liquid measurement. PMC11/PMP11 is the cheapest E+H pressure transmitter without display.
Compare

Continuous / Liquids

Measuring Principle Gauge pressure
Characteristic / Application Cost effective pressure transducer, capacitive sensor with ceramics measuring diaphragm
Supply / Communication Analogue output:
10…30 VDC
0...10 V output:
12…30 VDC
Accuracy 0.5%
Long term stability 0.2 % of URL/year
Ambient temperature -40 °C…+70 °C
(-40 °F…+158 °F)
Process temperature -25 °C…+85 °C
(-13 °F…+185 °F)
Process pressure / max. overpressure limit max. 60 bar (900 psi)
Pressure measuring range +400 mbar…+40 bar
(+6 psi...+600 psi)
Process connection Threads:
G1/4, G1/2,
MNPT 1/4, MNPT 1/2,
DIN13
Communication 4...20 mA
0...10 V
Design approvals EN10204-3.1 Final inspection report
Cleaned from oil and grease

Pressure

Measuring Principle Gauge pressure
Characteristic Cost effective pressure transducer, capacitive sensor with ceramics measuring diaphragm
Supply voltage Analogue output: 10…30 VDC
0...10 V output: 12…30 VDC
Reference Accuracy 0.5 %
Long term stability 0.2 % of URL/year
Process temperature -25 °C…+85 °C
(-13 °F…+185 °F)
Ambient temperature -40 °C…+70 °C
(-40 °F…+158 °F)
Measuring cell +400 mbar…+40 bar
(+6 psi...+600 psi)
Max. overpressure limit max. 60 bar (900 psi)
Process connection Threads:
G1/4, G1/2,
MNPT 1/4, MNPT 1/2,
DIN13
Communication 4...20 mA
0...10 V
Design approvals EN10204-3.1 Final inspection report
Cleaned from oil and grease

The Cerabar PMC11 is the most cost-effective compact pressure transmitter. With a capacitive, non-oil-filled ceramic diaphragm sensor, its gauge pressure measuring range is 400 mbar...40 bar. The PMC11 can be used in standard applications in the process industry and uses high-quality materials such as 316L and 99.9% Al2O3 to meet various application conditions.

 

Advantages

The compact transmitter design with customizable measuring range enables convenient and time-saving installation and setup in plants

High long-term stability and repeatability combined with a reference accuracy of up to 0.5%, ensuring high-quality process monitoring in general process applications

The ceramic diaphragm uses a non-oil-filled capacitive sensor with strong wear resistance and passes various tests, ensuring excellent long-term stability in process applications

 

Areas of application

Pressure transmitter with non-oil-filled ceramic diaphragm sensor for gauge pressure measurement in gases or liquids.

 

Process connection: thread

Process temperature: -25...+85°C (-13...+185°F)

Process pressure: 400 mbar...+40 bar (6...600 psi)

Measurement accuracy: ±0.5% of full scale

Spare Parts & Accessories 4

4 spare parts · click to collapse
Order codeDescription
71280307Hirschmann connector M16Consists of: plug connector, screw, seal, valve plug ring, adapter ring. Usage: FTI26, FTL31/FTL33, FTW33, PMC11, PMC21, PMP11, PMP21/PMP23.Details
71280349Hirschmann connector NPTF1/2Consists of: plug connector, screw, seal, valve plug ring, adapter ring. Usage: FTI26, FTL31/FTL33, FTW33, PMC11, PMC21, PMP11, PMP21/PMP23.Details
52006263Process connection | Socket for plug 4p-125V, 4A-M12M12 插头 自连接 M12转成格兰Details
52010285M12 connector, 90° angled, with 5 m cable适用于M12插头 带5m电缆 PVC材质,铜镀锡/ 镍锁紧螺母Details

Configurator / Comparison

ConfigureEnter a product model to configure
CompareEnter the product models to compare — up to three products

   

   

 

 

Source:Endress+Hauserwebsite public information

Measuring principle video

Click to play
16 models · click to collapse
All documents for this model
4 documents · click to expand
BA

BA Cerabar PMC11, PMC21, PMP11, PMP21, PMP23 Chinese

Rev. 0721 44 pages
Preview
BA

Cerabar PMC11, PMC21, PMP11, PMP21, PMP23 English

Rev. 0721 48 pages
Preview
TI

TI Cerabar PMC11, PMC21, PMP11, PMP21 Chinese

Rev. 0825 44 pages
Preview
TI

TI Cerabar PMC11, PMC21, PMP11, PMP21 English

Rev. 0825 48 pages
Preview
Municipal Wastewater Treatment

Municipal Wastewater Treatment · Gauge and Absolute Pressure — Application Case

Site Conditions

This is a Municipal Wastewater Treatment customer whose plant is at the inlet, biological and outlet stages of a municipal plant. The main task was measuring gauge or absolute pressure to judge process state.

The Problem

The difficulty lies in high solids and corrosive fractions, with large diurnal flow swings; at the same time effluent parameters drift and probes foul with sludge and biofilm. Specification therefore means selected by turndown, overpressure protection and diaphragm material.

What We Did

We took a pressure range approach — pressure solution matched to process pressure and temperature. Delivery was built around selected by turndown, overpressure protection and diaphragm material, with point-by-point checks on: stable compliance with Grade 1A discharge limits and online data reporting.

Operating Outcome

In service the system performs as intended — spotting abnormal pressure early, before equipment is damaged, with routine maintenance falling noticeably.

Food & Beverage

Food & Beverage · Gauge and Absolute Pressure — Application Case

Application Context

dosing, pasteurising, filling and CIP stages is a typical Food & Beverage duty. The project started from Gauge and Absolute Pressure, focusing on measuring gauge or absolute pressure to judge process state.

Process Constraints

frequent cleaning demands instruments that withstand hot CIP/SIP caustic cycles, and syrups, dairy and beverages that scale easily, under strict hygienic requirements only amplify it. The Gauge and Absolute Pressure specification must therefore cover selected by turndown, overpressure protection and diaphragm material.

Delivery Approach

Delivery was handled as the pressure range — pressure solution matched to process pressure and temperature. Execution centred on selected by turndown, overpressure protection and diaphragm material, together with food-safety and hygienic design per 3-A / EHEDG.

Field Results

Operation shows the benefit clearly — spotting abnormal pressure early, before equipment is damaged, with confidence in this measuring point improving markedly.

Chemical & Pharmaceutical

Chemical & Pharmaceutical · Gauge and Absolute Pressure — Application Case

Customer Profile

The typical setting in Chemical & Pharmaceutical is reactors, metering vessels and finished-product tanks. The measuring point is Gauge and Absolute Pressure; the focus is measuring gauge or absolute pressure to judge process state.

Key Difficulties

Conditions are highly corrosive media with solvents and crystallisation, partly in explosive atmospheres and, on top of that, corrosion plus Ex protection shortens instrument life and makes downtime costly, which a standard configuration cannot handle for long. The design therefore starts with selected by turndown, overpressure protection and diaphragm material.

Implementation

The scope ran through the pressure range: pressure solution matched to process pressure and temperature. Technically it hinges on selected by turndown, overpressure protection and diaphragm material, and on these requirements: Ex certification and GMP traceability of records.

Customer Benefit

In practice this means spotting abnormal pressure early, before equipment is damaged, which cut the workload on the site maintenance team.

Power & Energy

Power & Energy · Gauge and Absolute Pressure — Application Case

Project Background

The project covers boiler feedwater, turbine condensate and FGD/DeNOx systems. The work centres on Gauge and Absolute Pressure and the core task is measuring gauge or absolute pressure to judge process state.

Operating Challenges

The medium and duty are characterised by high temperature and pressure with both steam and saline water, and drift under high temperature and pressure, with very costly unplanned outages. So Gauge and Absolute Pressure cannot be specified generically — it calls for selected by turndown, overpressure protection and diaphragm material.

Solution

The Ainstru engineering team worked through the pressure range: pressure solution matched to process pressure and temperature. The configuration involves selected by turndown, overpressure protection and diaphragm material, with these requirements in view: compliance with power-industry codes and unit availability targets.

Results

Since start-up the system has run steadily; the practical result is spotting abnormal pressure early, before equipment is damaged.