PTP33B E+H pressure switch

PTP33B E+H pressure switch
Ceraphant PTP33B
Configurable Models 4 models
The PTP33B economical pressure switch adopts an integral welded metal diaphragm sensor, which can be used in sanitary industry applications.
Compare

Pressure

Measuring Principle Pressure switch
Characteristic Intelligent pressure switch with metal diaphragm for hygienic applications,
longterm stable
Supply voltage 10....30 VDC
Reference Accuracy 0.5 %,
Platinum: 0.3 %
Long term stability 0.2 % of URL/year
Process temperature -40 °C...+100 °C
(-40 °C...+212 °F)
Ambient temperature -20 °C...+70 °C
(-4 °F...+158 °F)
Measuring cell +400 mbar....+40 bar
(+6 psi....+600 psi)
Max. overpressure limit 160 bar (2320 psi)
Process connection Thread: M24
Process connection hygienic DIN11851, Tri Clamp, SMS, Varivent
Communication 1x PNP switch
2x PNP switch
1x PNP switch + 4...20 mA analogue
Design approvals EN 10204-3.1 final inspection report,
Cleaned from oil and grease,
Set min alarm
Hygienic approvals FDA concurring
3A, EHEDG,
EG1935/2004
Specialities Digital display,
Fully welded process connections

The PTP33B is a pressure switch for hygienic applications. For non-hygienic applications, use the metal diaphragm pressure switch PTP31B, and for ceramic diaphragms use PTC31B.

The Ceraphant PTP33B is a highly cost-effective pressure switch with a metal diaphragm sensor for safe absolute and gauge pressure monitoring. The compact pressure switch has high stability and strong overload resistance. The stainless steel PTP33B has 3-A and EHEDG approvals.

 

Advantages

Integrated electronic switch module for monitoring and control in discrete and process industries

Function check and on-site information display via LED indicator and digital display

Compact pressure transmitter that meets hygienic application requirements

Resistant to CIP/SIP cleaning

Small, flush-mounted hygienic process connection with 3-A and EHEDG approvals

 

Application areas

Pressure switch for absolute and gauge pressure monitoring of gases, steam, liquids or dust.

 

Process connection: hygienic connection, threaded connection

Process temperature: -10...+100°C (+14...+212°F) (+135°C (275°F): for 1 hour)

Process pressure: 400 mbar...+40 bar (6...+600 psi)

Measuring accuracy: max. ±0.3%

Spare Parts & Accessories 44

44 spare parts · click to collapse
Order codeDescription
71336104Hirschmann connector M164-pole. Consists of: plug connector, srew, seal. Usage: PTC31B, PTP31B/PTP33B.Details
71336105Hirschmann connector NPTF1/24-pole. Consists of: plug connector, srew, seal. Usage: PTC31B, PTP31B/PTP33B.Details
71337274O-ringConsisting of: 5x O-ring 15,54x2,62 FKM,FDA. Usage: FMP53, FMR43, FMR63B, PMP23, PTP33B, QMW43.Details
52010285M12 connector, 90° angled, with 5 m cable适用于M12插头 带5m电缆 PVC材质,铜镀锡/ 镍锁紧螺母Details
52006263Process connection | Socket for plug 4p-125V, 4A-M12M12 插头 自连接 M12转成格兰Details
52005087welded socket, G1齐平式安装 材质: 316L. 可用于: PMP23, PMP51, PMP135, PTP33B/PTP35. 建议焊接时使用堵头Details
52010171Weld socket, G1, 3.1 material certificateFlush mount process connection PMP135 "M", PTP35 "BA", PMP45 "CD" Material: 316L Inspection cert. EN10204-3.1 material Correct installation only with dummyDetails
52001051Process connection | Weld-in G1, d=60, 316L齐平安装式过程连接 FTL260 "0", FTL20 "7", FTL20H "GEJ", FTL330H/FTL330L "G", FTL50/FTL51, FTL50H/FTL51H "GW2", FMI51/FMI52, FTI51/FTI52 "GWJ", PMP135 "N", PTP35 "BB" 材质: 316L 密封: 硅橡胶 O-ringDetails
52011896Welding socket, G1, d=60, 3.1 material certificateFlush mount process connection FTL260 "0", FTL20H "GEJ", FTL50/FTL51, FTL50H/FTL51H "GW2", FMI51/FMI52, FTI51/FTI52 "GWJ", PMP135 "N", PTP35 "BB" Material: 316L Seal: Silicone O-ring Inspection cert. EN10204-3.1 material (316L wetted parts)Details
71258358Weld socket G1, d=53, 316LFlush mount process connection. Material: 316L. Seal: silicone O-ring. FDA, 3-A compliant. Additional EPDM O-ring. FDA, EHEDG, 3-A, USP Class VI compliant. Usage: FMI51, FMI52, FTI51, FTI52, FTL31, FTL33, FTL41, FTL43, FTL50, FTL50H, FTL51, FTL51H, FTL51B, FTL63, FTL80, FTL81, FTL260, FTL330H, FTL330L, PTP35, PTP33B, PMP23, PMP43, PMP51, FTW23, FTW33, QMW43.Details
52005272Weld boss protection plugto avoid any deformation of nozzle 52005087 / 52010171 during weldingDetails
71675410Welding protective plug for weld-on connector; G1; brass materialWelding dummy for welding the weld-in adapter G1 71258358/71093129, 52001051/52011896. Material: Brass. Usage: FMI51, FMI52, FTI51, FTI52, FTL31, FTL33, FTL41, FTL43, FTL51B, FTL60, FTL63, FTL80, FTL81, FTW23, FTW33, PTP33B, PMP23, PMP43, TMR35, TM311, TM371, TM372, TM411, TT411.Details
71675413welding boss blind plugBlind plug with inspection certificate EN10204-3.1. for closing weld-in adapter G1 71258358/71093129, 52001051/52011896. Material: AISI 316L (1.4435). Roughness (process side): Ra < 0.76 μm (29.9 μin). Silicone O-ring. Usage: FMI51, FMI52, FTI51, FTI52, FTL31, FTL33, FTL41, FTL43, FTL51B, FTL60, FTL63, FTL80, FTL81, FTW23, FTW33, PTP33B, PMP23, PMP43, TMR35, TM311, TM371, TM372, TM411, TT411.Details
71041381Welded boss M24 D65Flush mount process connection. Core hole: 65mm. Material: 316L. Seal: EPDM O-ring FDA, EHEDG, 3-A compliant. Usage: FMP53, FTL33, FTW23, FTW33, PMP23, PTP33B, QMW43.Details
71041383Welding boss M24 D65, 3.1 material certificateFlush mount process connection. Core hole: 65mm. Material: 316L. Inspection cert. EN10204-3.1 material. Seal: EPDM O-ring. FDA, EHEDG, 3-A compliant. Usage: FMP53, FTL33, FTW23, FTW33, PMP23, PTP33B, QMW43.Details
71580894UNI D65/85 blind plug welding adapterConsists of: Blind plug, 316L. Groove nut, 1.4301/304. Form seal silicon. Usage: PMP23, PTP33B, PMC51, PMP55, FMB50, FMB70, FMD71.Details
52014472O-ringfor weld-in adapter G1 (52001051) Liquiphant M "GW2" Liquiphant T "7", Liquicap M "GWJ", Cerabar T PMP135 "N", Ceraphant T PTP35 "BB" for weld-in andapter G1, 316L 3.1 (52011896) Liquiphant M "GW2", Cerabar T PMP135 "N", Ceraphant T PTP35 "BB" for sliding sleeve Soliphant TDetails
71086102O-ringMaterial: silicone VMQ. USP Class VI. Usage: weld-in adapter G1, 316L, (52001051) flush mount, FMI51/FMI52, FTI51/FTI52, FTL31/FTL33, FTW23/FTW33, PMP23, PMP43, PMP51, PTP33B, FTL50/FTL50H/FTL51/FTL51H, FTL80/FTL81, QMW43, Weld-in adapter G1, 316L, 3.1, (52011896) flush mount, FMI51/FMI52, FTI51/FTI52, FTL31/FTL33, FTW23/FTW33, PMP23, PMP43, PMP51, PTP33B, FTL50/FTL50H/FTL51/FTL51H, FTL80/FTL81,QMW43, sliding sleeve FTM21.Details
71140668O-ringMaterial: EPDM 70. USP Class VI, 3-A. Usage: weld-in adapter G1, 316L, (52001051) flush mount, FMI51, FMI52, FTI51, FTI52, FTL31, FTL33, FTL43, FTW23, FTW33, PMP23, PMP51, PTP33B, FTL50, FTL50H, FTL51, FTL51H, FTL80, FTL81, PMP43, QMW43, Weld-in adapter G1, 316L, 3.1, (52011896) flush mounted, FMI51, FMI52, FTI51, FTI52, FTL31, FTL33, FTW23, FTW33, PMP23, PMP51, PTP33B, FTL50, FTL50H, FTL51, FTL51H, FTL80, FTL81, PMP43, QMW43, sliding sleeve FTM21.Details
52023994Process adapter M24 - Clamp 1 1/2"Exchange process connection Ceraphant T M24 female, O-ring 15,54x2,62mm, 316LDetails

Configurator / Comparison

ConfigureEnter a product model to configure
CompareEnter the product models to compare — up to three products

   

   

 

 

Accessories / Spare parts

 

Source:Endress+Hauserpublic information from the website

Measuring principle video

Click to play
4 models · click to collapse
All documents for this model
8 documents · click to expand
BA

BA Ceraphant PTC31B, PTP31B, PTP33B Chinese

Rev. 0925 80 pages
Preview
BA

BA Ceraphant PTC31B, PTP31B, PTP33B IO-Link Chinese

IO-Link Rev. 0525 84 pages
Preview
BA

BA Ceraphant PTC31B, PTP31B, PTP33B English

Rev. 0925 88 pages
Preview
BA

BA Ceraphant PTC31B, PTP31B, PTP33B IO-Link English

IO-Link Rev. 0525 92 pages
Preview
TI

TI 焊接接头、过程转接头和法兰 Chinese

Rev. 2726 130 pages
Preview
TI

TI Ceraphant PTP33B Chinese

Rev. 1025 40 pages
Preview
TI

TI Weld-in adapter, process adapter and flanges English

Rev. 2726 132 pages
Preview
TI

TI Ceraphant PTP33B English

Rev. 1025 40 pages
Preview
Municipal Wastewater Treatment

Municipal Wastewater Treatment · Gauge and Absolute Pressure — Application Case

Site Conditions

This is a Municipal Wastewater Treatment customer whose plant is at the inlet, biological and outlet stages of a municipal plant. The main task was measuring gauge or absolute pressure to judge process state.

The Problem

The difficulty lies in high solids and corrosive fractions, with large diurnal flow swings; at the same time effluent parameters drift and probes foul with sludge and biofilm. Specification therefore means selected by turndown, overpressure protection and diaphragm material.

What We Did

We took a pressure range approach — pressure solution matched to process pressure and temperature. Delivery was built around selected by turndown, overpressure protection and diaphragm material, with point-by-point checks on: stable compliance with Grade 1A discharge limits and online data reporting.

Operating Outcome

In service the system performs as intended — spotting abnormal pressure early, before equipment is damaged, with routine maintenance falling noticeably.

Food & Beverage

Food & Beverage · Gauge and Absolute Pressure — Application Case

Application Context

dosing, pasteurising, filling and CIP stages is a typical Food & Beverage duty. The project started from Gauge and Absolute Pressure, focusing on measuring gauge or absolute pressure to judge process state.

Process Constraints

frequent cleaning demands instruments that withstand hot CIP/SIP caustic cycles, and syrups, dairy and beverages that scale easily, under strict hygienic requirements only amplify it. The Gauge and Absolute Pressure specification must therefore cover selected by turndown, overpressure protection and diaphragm material.

Delivery Approach

Delivery was handled as the pressure range — pressure solution matched to process pressure and temperature. Execution centred on selected by turndown, overpressure protection and diaphragm material, together with food-safety and hygienic design per 3-A / EHEDG.

Field Results

Operation shows the benefit clearly — spotting abnormal pressure early, before equipment is damaged, with confidence in this measuring point improving markedly.

Chemical & Pharmaceutical

Chemical & Pharmaceutical · Gauge and Absolute Pressure — Application Case

Customer Profile

The typical setting in Chemical & Pharmaceutical is reactors, metering vessels and finished-product tanks. The measuring point is Gauge and Absolute Pressure; the focus is measuring gauge or absolute pressure to judge process state.

Key Difficulties

Conditions are highly corrosive media with solvents and crystallisation, partly in explosive atmospheres and, on top of that, corrosion plus Ex protection shortens instrument life and makes downtime costly, which a standard configuration cannot handle for long. The design therefore starts with selected by turndown, overpressure protection and diaphragm material.

Implementation

The scope ran through the pressure range: pressure solution matched to process pressure and temperature. Technically it hinges on selected by turndown, overpressure protection and diaphragm material, and on these requirements: Ex certification and GMP traceability of records.

Customer Benefit

In practice this means spotting abnormal pressure early, before equipment is damaged, which cut the workload on the site maintenance team.

Power & Energy

Power & Energy · Gauge and Absolute Pressure — Application Case

Project Background

The project covers boiler feedwater, turbine condensate and FGD/DeNOx systems. The work centres on Gauge and Absolute Pressure and the core task is measuring gauge or absolute pressure to judge process state.

Operating Challenges

The medium and duty are characterised by high temperature and pressure with both steam and saline water, and drift under high temperature and pressure, with very costly unplanned outages. So Gauge and Absolute Pressure cannot be specified generically — it calls for selected by turndown, overpressure protection and diaphragm material.

Solution

The Ainstru engineering team worked through the pressure range: pressure solution matched to process pressure and temperature. The configuration involves selected by turndown, overpressure protection and diaphragm material, with these requirements in view: compliance with power-industry codes and unit availability targets.

Results

Since start-up the system has run steadily; the practical result is spotting abnormal pressure early, before equipment is damaged.