Instrumentation · Engineering · Package · PLC
0755-82221901 sales@ainstru.com

PMP71 pressure transmitter

PMP71 pressure transmitter
Cerabar S PMP71
Configurable Models 20 models
Digital pressure transmitter using welded metal sensors, suitable for gas, steam, and liquid measurement
Compare

Continuous / Liquids

Measuring Principle Absolute and gauge pressure
Characteristic / Application Digital transmitter with piezoresistive sensor and welded metallic membrane
Modular transmitter
Long term stability
Enhanced safety via self diagnostic functions
Secondary process barrier
Specialities diagnostic functionalities
different languages in software
Supply / Communication 4...20mA HART:
10,5...45V DC
Ex ia: 10,5...30V DC
PROFIBUS PA /
FOUNDATION Fieldbus:
9...32V DC
Accuracy Standard: 0.05%
Platinum: up to 0.025%
Long term stability 0,05% of URL/year
Ambient temperature -50°C...85°C
(-58°F...185°F)
Process temperature -40°C...125°C
(-40°F...257°F)
Process pressure / max. overpressure limit 1050bar (15,750psi)
Pressure measuring range 400 mbar...700 bar
(5.8 psi...10.500 psi)
Main wetted parts Alloy C276
316L
Rhodium
Process connection Threads
Flanges (DIN, ASME, ...) with flush membrane
Max. measurement distance 7000m (22.966ft) H2O
Communication 4...20 mA HART
1- 5V DC Low Power
PROFIBUS PA
FOUNDATION Fieldbus
Certificates / Approvals ATEX, FM, CSA, CSA C/US, IEC Ex, JPN Ex, INMETRO, NEPSI, EAC
Safety approvals SIL
Design approvals EN 10204-3.1
NACE MR0175, MR0103
Marine approval GL/ ABS
Drinking water approvals NSF
Options HistoROM/M-Dat
4-line digital display
SS- or Aluminiumhousing
Separate housing
Successor PMP71B
Application limits Measuring cell: Metal
welded
If pressurized, possibly
use differential pressure
meas-urement with two
pressure transmitters
(electronic dp). Observe
ratio head pressure :
hydrostatic pressure

Pressure

Measuring Principle Absolute and gauge pressure
Characteristic Digital transmitter with piezoresistive sensor and welded metallic membrane
Modular transmitter
Long term stability
Enhanced safety via self diagnostic functionsSecondary process barrier
Supply voltage 4...20 mA HART
10,5...45V DC (Non Ex):
Ex ia: 10,5...30V DC
PROFIBUS PA:
9...32 V DC (Non Ex)
FOUNDATION Fieldbus:
9...32 V DC (Non Ex)
Reference Accuracy Standard: 0.05%
Platinum: up to 0.025%
Long term stability 0.05 % of URL/ year
0.07 % of URL/ 5 years
0.1 % of URL/ 10 years
Process temperature -40°C...125°C
(-40°F...257°F)
Ambient temperature -50°C...85°C
(-58°F...185°F)
Measuring cell 400 mbar...700 bar
(5.8 psi...10.500 psi)
relative/ absolute
Smallest calibratable span 5 mbar (0.075 psi)
Vacuum resistance 10 mbar (0.15 psi)
Max. Turn down 100:1
Max. overpressure limit 1050 bar (15.750 psi)
Process connection Thread:
G1/2...G2, R1/2, MNPT1/2...MNPT2, R1/2
Flange:
DN25...DN80,
ASME 1"...4",
JIS 10K...20K
Material process membrane 316L, AlloyC,
Rhodium> Gold
Material gasket None, measuring cell welded
Fill fluid Silicone oil,
Inert oil
Material housing Die-cast aluminum,
AISI 316L
Communication 4...20 mA HART
1- 5V DC Low Power
PROFIBUS PA
FOUNDATION Fieldbus
Certificates / Approvals ATEX, FM, CSA, CSA C/US, IEC Ex, JPN Ex, INMETRO, NEPSI, EAC, UK Ex
Safety approvals SIL
Design approvals EN10204-3.1
NACE MR0175
Marine approvals GL/ABS
Drinking water approvals NSF
Specialities Diagnostic functions
Successor PMP71B

The Cerabar PMP71 digital pressure measuring transmitter uses a metal diaphragm and is mainly used in the process industry to measure the pressure, level, volume and mass of liquids and gases. The PMP71 is designed for high-pressure measurement applications with a maximum working pressure of up to 700bar. It features a quick setup function and an adjustable measuring range. The design complies with IEC 61508 and meets SIL2/3 functional safety requirements. It is available with a MID custody transfer certificate and is suitable for custody transfer.

 

Advantages

Precise measurement even under changing process temperature conditions

HistoROM®/M-DAT memory unit enables traceability of device settings and measured values

IEC 61508 certified by TÜV SÜD, suitable for SIL2/SIL3 functional safety process monitoring (max.…min.…range)

Overload protection and function monitoring from the measuring diaphragm to the electronics

Quick setup menu for fast setting of basic commissioning parameters, menu-guided operation with advanced fault diagnostics

Optional manifold: also pressure-tested

Seamless, independent system integration (HART/PA/FF)

 

Areas of application

Dual-compartment aluminum or stainless steel (316L) housing

 

Process connection: thread, flange

Temperature range: -40 to +125°C (-40 to +257°F)

Pressure range: +100mbar to +700bar (+1.5 to +10,500psi)

Accuracy: ±0.05%, "platinum version" ±0.025%

International explosion protection approval, WHG overflow protection, hygienic approval, marine approval, SIL

Spare Parts & Accessories 92

92 spare parts · click to collapse
Order codeDescription
52020440mounting kitconsists of: 2x O-ring 45.69x2.62 EPDM retaining ring, plastics Cerabar S PMC71, PMP71/PMP75 Deltabar S PMD70/PMD75,FMD76/FMD77/FMD78 Deltapilot S FMB70Details
71020596mounting kitconsists of: 2x O-ring 45.62x69x2.62 EPDM 1x profile gasket 51.4x57.2x1.6 VMQ retaining ring, plastics Cerabar S PMC71/PMP71/PMP75 Deltabar S PMD70/PMD75/FMD76/FMD77/FMD78 Deltapilot S FMB70Details
52022418key housingfor external operation consists of: push buttons, cover + screwsDetails
52022419key housingfor external operation consists of: push buttons, cover + screws colour: light greyDetails
52024110key housingfor external operation consists of: push button, cover + screws colour: dark greyDetails
52020760cable glandconsists of: cable gland M20 O-ring 18.72x2.62 VMQ Cerabar S PMC71, PMP71/PMP75 Deltabar S PMD70/PMD75,FMD76/FMD77/FMD78 Deltapilot S FMB70Details
52020761cable entryconsists of: gasket 18.72x2.51 NBR adapter M20 > G1/2 O-ring 18.77x1.78 NBR Cerabar S PMC71, PMP71/PMP75 Deltabar S PMD70/PMD75,FMD76/FMD77/FMD78 Deltapilot S FMB70Details
52020762plug connectorHarting plug set Cerabar S PMC71, PMP71/PMP75 Deltabar S PMD70/PMD75,FMD76/FMD77/FMD78 Deltapilot S FMB70Details
52020763plug connectorCerabar S PMC71, PMP71/PMP75 Deltabar S PMD70/PMD75,FMD76/FMD77/FMD78 Deltapilot S FMB70Details
71111056Atmospheric compensation filter portConsists of: Vent screw 304. Pressure compensation filter. O-ring EPDM, protection lid. Usage: FMB50, FMB51, FMB52, FMB53, FMD71, FMD72, FMD76, FMD77, FMD78, FMR60B, FMR62B, FMR63B, FMR66B, FMR67B, PMC51, PMC71, PMD70, PMD75, PMP71, PMP75, PMP51, PMP55.Details
71219639Atmospheric compensation filter portConsists of: vent screw 304. Pressure compensation filter. O-ring VMQ, protection lid. Usage: housing T17, FMB70, FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/ PMP75. Housing F15 at B1,BB,BD,BF,GA,ID,I1, FMB50/FMB51/FMB52/FMB53, PMC51, PMP51/PMP55.Details
52020432Aluminum cover with gasketMaterial: Aluminium, coated O-ring EPDM, FDA not for EEx d/XP Cerabar S PMC71, PMP71/PMP75 Deltabar S PMD70/PMD75,FMD76/FMD77/FMD78 Deltapilot S FMB70Details
71002810cover with viewing windowMaterial: 316L Sight glass: mineral glass flat gasket VMQ, centering ring, screw approval 2,3,4,8,Q,W,7,8 Cerabar S PMC71, PMP71/PMP75 Deltabar S PMD70/PMD75,FMD76/FMD77/FMD78 Deltapilot S FMB70Details
71002811cover with viewing windowMaterial: 316L Sight glass: Polycarbonat PC flat gasket VMQ, centering ring, screw approval A,F,R,S,U,1,6 Cerabar S PMC71, PMP71/PMP75 Deltabar S PMD70/PMD75,FMD76/FMD77/FMD78 Deltapilot S FMB70Details
71002774Stainless Steel CoverMaterial: 316L flat gasket VMQ, centering ring, screw not for EEx d/XP Cerabar S PMC71, PMP71/PMP75 Deltabar S PMD70/PMD75,FMD76/FMD77/FMD78 Deltapilot S FMB70Details
52020433Aluminum cover with gasketMaterial: Aluminium, coated O-ring EPDM, FDA for EEx d/XP Cerabar S PMC71, PMP71/PMP75 Deltabar S PMD70/PMD75,FMD76/FMD77/FMD78Details
71245247Aluminum coverMaterial: aluminium, coated. Sight glass: mineral glass, coated. O-ring EPDM, FDA. Not for EEx d/XP. Usage: FMB70, FMD71/FMD72/FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.Details
71245249Aluminum coverMaterial: aluminium. Sight glass mineral glass, coated. O-ring EPDM, FDA. Individual tested, EEx d/XP. Usage: FMD71/FMD72/FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.Details
52028310Stainless Steel CoverMaterial: 316L O-ring EPDM, FDA individual tested, EEx d/XP Cerabar S PMC71, PMP71/PMP75 Deltabar S PMD70/PMD75,FMD76/FMD77/FMD78Details
71245250CoverMaterial: 316L. Sight glass: mineral glass, coated. O-ring EPDM, FDA. Individual tested, EEx d/XP. Usage: FMD71/FMD72/FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.Details

Configurator / Comparison

ConfigureEnter a product model to configure
CompareEnter the product models to compare — up to three products

   

   

 

 

Source:Endress+Hauserwebsite public information

Measuring principle video

Click to play
21 models · click to collapse
Diagnostic codes(60 条)→
All documents for this model
12 documents · click to expand
BA

Cerabar S PMC71, PMP71, PMP75 HART V02.30.zz Operating Instructions Chinese

HART Rev. 2022 68 pages
Preview
BA

Cerabar S PMC71, PMP71, PMP75 FOUNDATION Fieldbus (V 04.00.zz) Operating Instructions Chinese

FOUNDATION-Fieldbus Rev. 1922 98 pages
Preview
BA

仪表功能描述 Cerabar S PMC71, PMP71/75 Deltabar S FMD76/77/78, PMD70/75 Deltapilot S FMB70 Chinese

Rev. 1413 168 pages
Preview
BA

Cerabar S PMC71, PMP71, PMP75 HART V02.30.zz Operating Instructions English

HART Rev. 2022 68 pages
Preview
BA

Cerabar S PMC71, PMP71, PMP75 FOUNDATION Fieldbus (V 04.00.zz) Operating Instructions English

FOUNDATION-Fieldbus Rev. 1922 98 pages
Preview
BA

Cerabar S PMC71, PMP71, PMP75 PROFIBUS PA (V 04.01.zz) Operating Instructions English

PROFIBUS-PA Rev. 1922 86 pages
Preview
BA

Cerabar S / Deltabar S / Deltapilot S HART V02.30.zz Description of Instrument Functions English

HART Rev. 1816 148 pages
Preview
BA

Cerabar S / Deltabar S / Deltapilot S, Description of device functions FOUNDATION Fieldbus V 04.00.zz English

FOUNDATION-Fieldbus Rev. 1716 258 pages
Preview
BA

Cerabar S /Deltabar S /Deltapilot S Description of device functions PROFIBUS PA V04.01.zz English

PROFIBUS-PA Rev. 1616 170 pages
Preview
BA

Operating Instructions HART (V02.10.54) Cerabar S PMP71 with MID Part Certificate English

HART Rev. 1316 60 pages
Preview
BA

Description of Device Functions HART (V02.10.54) Cerabar S PM71 with MID Part Certificate English

HART Rev. 1316 60 pages
Preview
BA

Cerabar S /Deltabar S /Deltapilot S Description of device functions PROFIBUS PA English

PROFIBUS-PA Rev. 0510 174 pages
Preview
Municipal Wastewater Treatment

Municipal Wastewater Treatment · Gauge and Absolute Pressure — Application Case

Site Conditions

This is a Municipal Wastewater Treatment customer whose plant is at the inlet, biological and outlet stages of a municipal plant. The main task was measuring gauge or absolute pressure to judge process state.

The Problem

The difficulty lies in high solids and corrosive fractions, with large diurnal flow swings; at the same time effluent parameters drift and probes foul with sludge and biofilm. Specification therefore means selected by turndown, overpressure protection and diaphragm material.

What We Did

We took a pressure range approach — pressure solution matched to process pressure and temperature. Delivery was built around selected by turndown, overpressure protection and diaphragm material, with point-by-point checks on: stable compliance with Grade 1A discharge limits and online data reporting.

Operating Outcome

In service the system performs as intended — spotting abnormal pressure early, before equipment is damaged, with routine maintenance falling noticeably.

Food & Beverage

Food & Beverage · Gauge and Absolute Pressure — Application Case

Application Context

dosing, pasteurising, filling and CIP stages is a typical Food & Beverage duty. The project started from Gauge and Absolute Pressure, focusing on measuring gauge or absolute pressure to judge process state.

Process Constraints

frequent cleaning demands instruments that withstand hot CIP/SIP caustic cycles, and syrups, dairy and beverages that scale easily, under strict hygienic requirements only amplify it. The Gauge and Absolute Pressure specification must therefore cover selected by turndown, overpressure protection and diaphragm material.

Delivery Approach

Delivery was handled as the pressure range — pressure solution matched to process pressure and temperature. Execution centred on selected by turndown, overpressure protection and diaphragm material, together with food-safety and hygienic design per 3-A / EHEDG.

Field Results

Operation shows the benefit clearly — spotting abnormal pressure early, before equipment is damaged, with confidence in this measuring point improving markedly.

Chemical & Pharmaceutical

Chemical & Pharmaceutical · Gauge and Absolute Pressure — Application Case

Customer Profile

The typical setting in Chemical & Pharmaceutical is reactors, metering vessels and finished-product tanks. The measuring point is Gauge and Absolute Pressure; the focus is measuring gauge or absolute pressure to judge process state.

Key Difficulties

Conditions are highly corrosive media with solvents and crystallisation, partly in explosive atmospheres and, on top of that, corrosion plus Ex protection shortens instrument life and makes downtime costly, which a standard configuration cannot handle for long. The design therefore starts with selected by turndown, overpressure protection and diaphragm material.

Implementation

The scope ran through the pressure range: pressure solution matched to process pressure and temperature. Technically it hinges on selected by turndown, overpressure protection and diaphragm material, and on these requirements: Ex certification and GMP traceability of records.

Customer Benefit

In practice this means spotting abnormal pressure early, before equipment is damaged, which cut the workload on the site maintenance team.

Power & Energy

Power & Energy · Gauge and Absolute Pressure — Application Case

Project Background

The project covers boiler feedwater, turbine condensate and FGD/DeNOx systems. The work centres on Gauge and Absolute Pressure and the core task is measuring gauge or absolute pressure to judge process state.

Operating Challenges

The medium and duty are characterised by high temperature and pressure with both steam and saline water, and drift under high temperature and pressure, with very costly unplanned outages. So Gauge and Absolute Pressure cannot be specified generically — it calls for selected by turndown, overpressure protection and diaphragm material.

Solution

The Ainstru engineering team worked through the pressure range: pressure solution matched to process pressure and temperature. The configuration involves selected by turndown, overpressure protection and diaphragm material, with these requirements in view: compliance with power-industry codes and unit availability targets.

Results

Since start-up the system has run steadily; the practical result is spotting abnormal pressure early, before equipment is damaged.