Instrumentation · Engineering · Package · PLC
0755-8222 1901 sales@ainstru.com

PMC51B pressure transmitter

PMC51B pressure transmitter

Cerabar PMC51B

Configurable Models 20 models
Intelligent transmitter with ceramic diaphragm sensor for high-precision liquid and gas measurement
Compare

Continuous / Liquids

Measuring Principle Absolute and gauge pressure
Characteristic / Application Pressure transmitter with ceramic process membran for accurate measurement in liquid or gases.
Intuitive and clear wizard for commissioning
Specialities Bluetooth® Operation and maintenance SmartBlue App,
RFID TAG for easy identification,
Plug and play functionalities
Supply / Communication Ex d, Ex e, non-Ex::
10.5...35V DC
Ex i: 10.5...30V DC
Accuracy Standard:
up to 0.075 %
Platinum:
up to 0.055 %
Long term stability 0.10 % of URL/ year
0.25 % of URL/ 5 years
0.40 % of URL/ 10 years
Ambient temperature -40°C...+85°C
(-40°F...+185°F)
Process temperature -40°C...+100°C
(-40°F...+212°F)
Process pressure / max. overpressure limit 40 bar (600 psi)
Pressure measuring range 100 mbar...40 bar
(1.5 psi...600 psi)
Main wetted parts Ceraphire ceramic
FKM, EPDM, HNBR,
Perlast, Kalrez
Process connection Thread:
G1/2...G2, R1/2, MNPT1/2...MNPT2, FNPT1/2
Flange:
DN25...DN80,
NPS 1"...4"
Max. measurement distance 400 m (1312 ft) H2O
Communication 4...20 mA,
4...20 mA HART
PROFINET with Ethernet-APL
Bluetooth® wireless
technology and app (optional)
Certificates / Approvals ATEX, IEC Ex, CSA C/US, NEPSI
Safety approvals SIL
Design approvals EN 10204-3.1
NACE MR0175,
NACE MR0103
Drinking water approvals NSF, KTW
Application limits Measuring cell: ceramics
If pressurized, possibly use differential pressure measurement with two pressure transmitters (electronic dp). Observe ratio head pressure : hydrostatic pressure

Pressure

Measuring Principle Absolute and gauge pressure
Characteristic Pressure transmitter with ceramic process membran for accurate measurement in liquid or gases.
Intuitive and clear wizard for commissioning
Supply voltage Ex d, Ex e, non-Ex:
10.5...35V DC
Ex i: 10.5...30V DC
Reference Accuracy Standard:
up to 0.075 %
Platinum:
up to 0.055 %
Long term stability 0.10% of URL/ year
0.25% of URL/ 5 years
0.40% of URL/ 10 years
Process temperature -40°C...+100°C
(-40°F...+212°F)
Ambient temperature -40°C...+85°C
(-40°F...+185°F)
Measuring cell 100 mbar...40 bar
(1.5 psi...600 psi)
Smallest calibratable span 5 mbar (0.075 psi)
Vacuum resistance 0 mbar abs.
Max. Turn down 100:1
Max. overpressure limit 60 bar (900 psi)
Process connection Thread:
G1/2...G2, R1/2, MNPT1/2...MNPT2,
FNPT1/2
Flange:
DN25...DN80,
NPS 1"...4"
Material process membrane Ceramic
Material gasket FKM, EPDM, HNBR, FFKM
Fill fluid none, dry measuring cell
Material housing Aluminium
Communication 4...20 mA,
4...20 mA HART
PROFINET with Ethernet-APL
Bluetooth® wireless
technology and app (optional)
Certificates / Approvals ATEX, CSA, IECEx, JPN Ex, INMETRO, NEPSI, UK Ex
Safety approvals SIL
Design approvals EN10204-3.1
NACE MR0175,
NACE MR0103
Drinking water approvals NSF, KTW
Specialities Bluetooth® Operation and maintenance SmartBlue App,
RFID TAG for easy identification,
Plug and play functionalities

The PMC51B is a member of the new generation of Cerabar transmitters. The instrument offers many advantages, such as convenient on-site or remote operation and condition-based maintenance.
The software is also very simple to use. The intuitive operating wizard guides the user step by step through instrument setup, functional safety tests and verification tests, minimizing the risk of operating errors. Using a mobile device and a secure Bluetooth connection, the transmitter can be controlled remotely via an app.

Advantages
Use the SmartBlue App to wirelessly and remotely control devices in the production area. No need to interrupt the production process.
Reduced risk of system failure, error-free SIL commissioning and guided instrument functional safety tests
Fewer on-site accidents and protection of devices installed at hard-to-reach measuring points

Application areas
Maximum applicable pressure: 40 bar (600 psi)
Fully vacuum-resistant at process temperatures up to +100°C (212°F)
Maximum measuring accuracy: +/-0.055%

 

E+H Product Model Configurator

Please enter the product model to configure

Product comparison

Please enter the product models to compare in the input fields below; up to three products can be compared

 

   

Technical documentation

   

Technical data

 

 

Documents / Manuals / Software

 

 

Accessories / Spare parts

 

Source:Endress+Hauserpublic information from the website

Model Name
PMC51B-AABACBA63HBI1WWJD+VD 压力变送器
PMC51B-AABACBA63PBI1WWJD+VD 压力变送器
PMC51B-BABACBA63MBI1WWCD+VD 压力变送器
PMC51B-BOBACBF63HBI1WWCD+VD 压力变送器
PMC51B-BOBACBF63FBI1WBED+VD 压力变送器
PMC51B-AABACBA63SBI1WWJD+VD 压力变送器
PMC51B-AABACBA63FBI1WBED+VD 压力变送器
PMC51B-AABACBA63HBI1WBED+VD 压力变送器
PMC51B-AABACBA63KBI1WWJD+VD 压力变送器
PMC51B-AABACBA63MBI1WBED+VD 压力变送器
PMC51B-BABACBA63MBI1WWJD+VD 压力变送器
PMC51B-BOBACBF63EBI1WBED+VD 压力变送器
PMC51B-BOBACBF63CBI1WBED+VD 压力变送器
PMC51B-BOBACBF63HBI1WBED+VD 压力变送器
PMC51B-AABACBA63SBI1WWCD+VD 压力变送器
PMC51B-BABACBA63CBI1WWCD+VD 压力变送器
PMC51B-BABACBA63KBI1WBED+VD 压力变送器
PMC51B-BABACBA63KBI1WWCD+VD 压力变送器
PMC51B-BABACBA63SBI1WWCD+VD 压力变送器
PMC51B-BOBACBF63MBI1WWCD+VD 压力变送器
Municipal Wastewater Treatment

Municipal Wastewater Treatment — Wastewater Treatment Plant · Gauge and Absolute Pressure Application Case

Project Background

Municipal Wastewater Treatment customers at the Wastewater Treatment Plant stage have long faced the challenge of insufficient accuracy in effluent quality monitoring and instruments prone to contamination causing data drift, affecting compliance discharge, placing higher demands on the stability and measurement accuracy of Gauge and Absolute Pressure.

Solution

Based on the on-site conditions, the Ainstru technical team selected suitable Gauge and Absolute Pressure for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.

Results

  • Measurement accuracy and response speed significantly improved, with stable and reliable data;
  • Instruments adapt to complex Municipal Wastewater Treatment conditions, greatly reducing maintenance;
  • Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.
Food & Beverage

Food & Beverage — Food Production Line · Gauge and Absolute Pressure Application Case

Project Background

Food & Beverage customers at the Food Production Line stage have long faced the challenge of high hygienic measurement requirements, with inline instruments needing to withstand CIP/SIP cleaning while maintaining stable accuracy, placing higher demands on the stability and measurement accuracy of Gauge and Absolute Pressure.

Solution

Based on the on-site conditions, the Ainstru technical team selected suitable Gauge and Absolute Pressure for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.

Results

  • Measurement accuracy and response speed significantly improved, with stable and reliable data;
  • Instruments adapt to complex Food & Beverage conditions, greatly reducing maintenance;
  • Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.
Chemical & Pharmaceutical

Chemical & Pharmaceutical — Reactors and Storage Tanks · Gauge and Absolute Pressure Application Case

Project Background

Chemical & Pharmaceutical customers at the Reactors and Storage Tanks stage have long faced the challenge of highly corrosive media and complex conditions, requiring corrosion-resistant and explosion-proof instruments, placing higher demands on the stability and measurement accuracy of Gauge and Absolute Pressure.

Solution

Based on the on-site conditions, the Ainstru technical team selected suitable Gauge and Absolute Pressure for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.

Results

  • Measurement accuracy and response speed significantly improved, with stable and reliable data;
  • Instruments adapt to complex Chemical & Pharmaceutical conditions, greatly reducing maintenance;
  • Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.
Power & Energy

Power & Energy — Power Plant Boiler and Turbine · Gauge and Absolute Pressure Application Case

Project Background

Power & Energy customers at the Power Plant Boiler and Turbine stage have long faced the challenge of unstable measurement under high temperature and pressure, with high maintenance and downtime costs, placing higher demands on the stability and measurement accuracy of Gauge and Absolute Pressure.

Solution

Based on the on-site conditions, the Ainstru technical team selected suitable Gauge and Absolute Pressure for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.

Results

  • Measurement accuracy and response speed significantly improved, with stable and reliable data;
  • Instruments adapt to complex Power & Energy conditions, greatly reducing maintenance;
  • Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.