Product family:
Cerabar S PMC71
Pressure transmitter
Cerabar S PMC71;Approval ATEX II 2G Ex db ia IIC T6 Gb;Output/Operating 4-20mA HART; inside;Housing/Cover Sealing/Cable Entry **T14 Alu IP66/67 NEMA6P; EPDM; NPT1/2 thread, T14 = side cover;Sensor Ran
Order Code:PMC71-5CC1P2A3DAA+Z1
Name:Cerabar S PMC71
Configuration
| Code | Name | Order | Specification |
|---|---|---|---|
| 010 | Approval | 5 | ATEX II 2G Ex db ia IIC T6 Gb |
| 020 | Output; Operating | C | 4-20mA HART; inside |
| 030 | Housing; Cover Sealing; Cable Entry | C | **T14 Alu IP66/67 NEMA6P; EPDM; NPT1/2 thread, T14 = side cover |
| 040 | Sensor Range; Sensor Overload Limit | 1P | 10bar/1MPa/150psi gauge; 40bar/4MPa/600psi |
| 050 | Calibration; Unit | 2 | Sensor range; kPa/MPa |
| 070 | Process Connection | A3 | **NPS 2" Cl.150 RF, PVDF, flush mount, flange ASME B16.5 max 10bar/150psi; -10...60oC/14...140oF |
| 080 | Seal | D | FFKM Kalrez 4079 |
| 100 | Additional Option 1 | A | Not selected |
| 110 | Additional Option 2 | A | Not selected |
| 895 | Marking | Z1 | Tagging (TAG), see additional spec. |
Configuration Explained
This PMC71 pressure transmitter has an oil-free ceramic sensor, ATEX flameproof with intrinsically safe circuit II 2G Ex d [ia] IIC T6 Gb, 4-20mA HART output with internal keys, T14 aluminium housing IP66/67, NPT1/2 cable gland, gauge pressure range 10 bar, overpressure limit 40 bar, process connection NPS 2" 150 lb RF flange, PVDF, flush mounting, FFKM seal, tag number stamped at the factory, suitable for corrosive media.