Instrumentation · Engineering · Package · PLC
0755-82221901 sales@ainstru.com

PMP51-AA21JA1SGCR1JA1+AK

PMP51-AA21JA1SGCR1JA1+AK
Product family: Cerabar M PMP51
Cerabar M PMP51
Endress+Hauser PMP51-AA21JA1SGCR1JA1+AK
Cerabar M PMP51;Approval Non-hazardous area;Output 4-20mA HART;Display, Operation LCD, push button on display/electronics;Housing F31 Alu, glass window;Electrical Connection Gland M20, IP66/68 NEMA4X/6P;Sensor Range 40bar/4MPa/600psi gauge, 400mH2O/1334ftH2O/16000inH2O overload: 160bar/16MPa/2400psi;Reference Accuracy Standard;Calibration/Unit Sensor range; kPa/MPa;Process Connection Thread ANSI FNPT1/2, 316L;Membrane Material 316L;Fill Fluid Silicone oil;Additional Operation

Order Code:PMP51-AA21JA1SGCR1JA1+AK

Name:Cerabar M PMP51

Configuration

CodeNameOrderSpecification
010ApprovalAANon-hazardous area
020Output24-20mA HART
030Display, Operation1LCD, push button on display/electronics
040HousingJF31 Alu, glass window
050Electrical ConnectionAGland M20, IP66/68 NEMA4X/6P
070Sensor Range1S40bar/4MPa/600psi gauge, 400mH2O/1334ftH2O/16000inH2O overload: 160bar/16MPa/2400psi
080Reference AccuracyGStandard
090Calibration; UnitCSensor range; kPa/MPa
110Process ConnectionR1JThread ANSI FNPT1/2, 316L
170Membrane MaterialA316L
180Fill Fluid1Silicone oil
500Additional Operation LanguageAKChinese simplified

Configuration Explained

This is a PMP51 digital pressure transmitter, welded metallic sensor, measures gases, liquids and steam, the most widely used E+H model in China, non-hazardous area, 24V two-wire 4-20mA HART output, with LCD display and key operation, F31 aluminium housing with glass window, M20 cable gland, IP66/68, overpressure limit 160 bar, calibrated in kPa/MPa, ANSI FNPT1/2 thread, 316L, 316L diaphragm with silicone oil, Chinese interface, suitable for medium and high pressure pipeline measurement.

75 models · click to collapse