Order Code:PMP51-B122QA1MGCG0JA3
Name:Cerabar M PMP51
Configuration
| Code | Name | Order | Specification |
|---|---|---|---|
| 010 | Approval | B1 | ATEX II1/2G Ex ia IIC T6 Ga/Gb + II1/2D Ex ia IIIC Da/Db |
| 020 | Output | 2 | 4-20mA HART |
| 030 | Display, Operation | 2 | W/o LCD, push button on electronics |
| 040 | Housing | Q | F15 stainless steel hygiene |
| 050 | Electrical Connection | A | Gland M20, IP66/68 NEMA4X/6P |
| 070 | Sensor Range | 1M | 4bar/400kPa/60psi gauge, 40mH2O/133ftH2O/1600inH2O overload: 28bar/2.8MPa/420psi |
| 080 | Reference Accuracy | G | Standard |
| 090 | Calibration; Unit | C | Sensor range; kPa/MPa |
| 110 | Process Connection | G0J | Thread ISO228 G1/2 sealing O-ring, flush mount, 316L, for adapter 52002643 |
| 170 | Membrane Material | A | 316L |
| 180 | Fill Fluid | 3 | Synthetic oil, FDA |
Configuration Explained
This is a PMP51 digital pressure transmitter, welded metallic sensor, with ATEX intrinsic safety and dust approvals II 1/2G Ex ia IIC T6, II 1/2D, 24V two-wire 4-20mA HART output, no LCD screen, push button operation, F15 stainless steel hygienic housing, M20 cable gland, IP66/68, gauge pressure range 4 bar, 40 m water column, overpressure 28 bar, G1/2 flush with O-ring, FDA synthetic oil, suitable for hygienic pipeline measurement in hazardous areas.