Instrumentation · Engineering · Package · PLC
0755-82221901 sales@ainstru.com

PMP51-CA22JA2SGBGVJA1

PMP51-CA22JA2SGBGVJA1
Product family: Cerabar M PMP51
Cerabar M PMP51
Endress+Hauser PMP51-CA22JA2SGBGVJA1
Cerabar M PMP51;Approval CSA C/US IS Cl.I,II,III Div.1 Gr.A-G, CSA C/US IS Cl.I Div.2 Gr.A-D, Ex ia, C: zone 0,1,2/US: zone 0,1,2,20,21,22;Output 4-20mA HART;Display, Operation W/o LCD, push button on electronics;Housing F31 Alu, glass window;Electrical Connection Gland M20, IP66/68 NEMA4X/6P;Sensor Range 40bar/4MPa/600psi abs, 400mH2O/1334ftH2O/16000inH2O abs overload: 160bar/16MPa/2400psi;Reference Accuracy Standard;Calibration/Unit Sensor range; mbar/bar;Process Connection

Order Code:PMP51-CA22JA2SGBGVJA1

Name:Cerabar M PMP51

Configuration

CodeNameOrderSpecification
010ApprovalCACSA C/US IS Cl.I,II,III Div.1 Gr.A-G, CSA C/US IS Cl.I Div.2 Gr.A-D, Ex ia, C: zone 0,1,2/US: zone 0,1,2,20,21,22
020Output24-20mA HART
030Display, Operation2W/o LCD, push button on electronics
040HousingJF31 Alu, glass window
050Electrical ConnectionAGland M20, IP66/68 NEMA4X/6P
070Sensor Range2S40bar/4MPa/600psi abs, 400mH2O/1334ftH2O/16000inH2O abs overload: 160bar/16MPa/2400psi
080Reference AccuracyGStandard
090Calibration; UnitBSensor range; mbar/bar
110Process ConnectionGVJThread ISO228 G1-1/2, 316L, flush mount
170Membrane MaterialA316L
180Fill Fluid1Silicone oil

Configuration Explained

This is a PMP51 digital pressure transmitter, welded metallic sensor, with CSA intrinsically safe approval Cl I Div 1, usable in Zones 0, 1 and 2, 24V two-wire 4-20mA HART output, no LCD screen, push button operation, F31 aluminium housing, M20 cable gland, IP66/68, absolute pressure range 40 bar, 400 m water column, overpressure 160 bar, calibrated in mbar/bar, G1-1/2 thread flush, 316L, suitable for absolute pressure measurement in North American hazardous areas.

75 models · click to collapse