Instrumentation · Engineering · Package · PLC
0755-82221901 sales@ainstru.com

PTC31B pressure switch

PTC31B pressure switch
Ceraphant PTC31B
Configurable Models 20 models
PTC31B capacitive structure pressure switch, using non oil filled ceramic diaphragm sensor for absolute or gauge pressure measurement
Compare

Pressure

Measuring Principle Pressure switch
Characteristic Intelligent pressure switch with capacitive sensor, long term stable and abrasion resistant
Supply voltage 10...30 VDC
Reference Accuracy 0.5 %,
Platinum: 0.3 %
Long term stability 0.2 % of URL/year
Process temperature -25 °C....+100 °C
(-13 °F....+212 °F)
Ambient temperature -20 °C...+70 °C
(-4 °C...+158 °F)
Measuring cell +100 mbar....+40 bar
(+1.5 psi....600 psi)
Max. overpressure limit 60 bar (900 psi)
Process connection Threads:
G1/4, G1/2,
MNPT1/4, MNPT1/2,
DIN13,
JIS R1/2
Communication 1x PNP switch
2x PNP switch
1x PNP switch +
4...20mA analogue
Design approvals EN 10204-3.1 Final inspection
report
Cleaned from oil and grease
Cleaned for oxygen applications
Set min alarm
Specialities Digital display

The Ceraphant PTC31B is a cost-effective pressure switch with a ceramic diaphragm sensor. The sensor is vacuum-resistant and can safely measure and monitor absolute and gauge pressure. The pressure switch has a compact design and high stability, withstands high vacuum and can withstand an absolute vacuum down to 0 bar.

 

Advantages

Built-in electronic switch component enables decentralized and economical monitoring

Convenient function check and on-site information display via LED indicator and digital display

The capacitive, non-oil-filled ceramic diaphragm sensor (Ceraphire) has a minimum range of 0...20 mbar for stable process monitoring

High process availability, suitable for vacuum applications and measurement of abrasive media

 

Areas of application

Pressure switch with ceramic diaphragm sensor for absolute and gauge pressure monitoring in gases, steam, liquids and dust.

 

Process connection: thread

Process temperature: -25...+100°C (-13...+212°F)

Pressure: -1/0...+40 bar (-15/0...+600 psi)

Measurement accuracy: ±0.3%

Spare Parts & Accessories 5

5 spare parts · click to collapse
Order codeDescription
71336104Hirschmann connector M164-pole. Consists of: plug connector, srew, seal. Usage: PTC31B, PTP31B/PTP33B.Details
71336105Hirschmann connector NPTF1/24-pole. Consists of: plug connector, srew, seal. Usage: PTC31B, PTP31B/PTP33B.Details
71114212M12 right-angle aviation connector, 90°自连接 可用于: M12插头Details
52010285M12 connector, 90° angled, with 5 m cable适用于M12插头 带5m电缆 PVC材质,铜镀锡/ 镍锁紧螺母Details
52006263Process connection | Socket for plug 4p-125V, 4A-M12M12 插头 自连接 M12转成格兰Details

Configurator / Comparison

ConfigureEnter a product model to configure
CompareEnter the product models to compare — up to three products

   

   

 

 

Source:Endress+Hauserwebsite public information

Measuring principle video

Click to play
148 models · click to collapse
All documents for this model
8 documents · click to expand
BA

BA Ceraphant PTC31B, PTP31B, PTP33B Chinese

Rev. 0925 80 pages
Preview
BA

BA Ceraphant PTC31B, PTP31B, PTP33B IO-Link Chinese

IO-Link Rev. 0525 84 pages
Preview
BA

BA Ceraphant PTC31B, PTP31B, PTP33B English

Rev. 0925 88 pages
Preview
BA

BA Ceraphant PTC31B, PTP31B, PTP33B IO-Link English

IO-Link Rev. 0525 92 pages
Preview
TI

TI 焊接接头、过程转接头和法兰 Chinese

Rev. 2726 130 pages
Preview
TI

TI Ceraphant PTC31B, PTP31B Chinese

Rev. 1025 48 pages
Preview
TI

TI Weld-in adapter, process adapter and flanges English

Rev. 2726 132 pages
Preview
TI

TI Ceraphant PTC31B, PTP31B English

Rev. 1025 48 pages
Preview
Municipal Wastewater Treatment

Municipal Wastewater Treatment · Gauge and Absolute Pressure — Application Case

Site Conditions

This is a Municipal Wastewater Treatment customer whose plant is at the inlet, biological and outlet stages of a municipal plant. The main task was measuring gauge or absolute pressure to judge process state.

The Problem

The difficulty lies in high solids and corrosive fractions, with large diurnal flow swings; at the same time effluent parameters drift and probes foul with sludge and biofilm. Specification therefore means selected by turndown, overpressure protection and diaphragm material.

What We Did

We took a pressure range approach — pressure solution matched to process pressure and temperature. Delivery was built around selected by turndown, overpressure protection and diaphragm material, with point-by-point checks on: stable compliance with Grade 1A discharge limits and online data reporting.

Operating Outcome

In service the system performs as intended — spotting abnormal pressure early, before equipment is damaged, with routine maintenance falling noticeably.

Food & Beverage

Food & Beverage · Gauge and Absolute Pressure — Application Case

Application Context

dosing, pasteurising, filling and CIP stages is a typical Food & Beverage duty. The project started from Gauge and Absolute Pressure, focusing on measuring gauge or absolute pressure to judge process state.

Process Constraints

frequent cleaning demands instruments that withstand hot CIP/SIP caustic cycles, and syrups, dairy and beverages that scale easily, under strict hygienic requirements only amplify it. The Gauge and Absolute Pressure specification must therefore cover selected by turndown, overpressure protection and diaphragm material.

Delivery Approach

Delivery was handled as the pressure range — pressure solution matched to process pressure and temperature. Execution centred on selected by turndown, overpressure protection and diaphragm material, together with food-safety and hygienic design per 3-A / EHEDG.

Field Results

Operation shows the benefit clearly — spotting abnormal pressure early, before equipment is damaged, with confidence in this measuring point improving markedly.

Chemical & Pharmaceutical

Chemical & Pharmaceutical · Gauge and Absolute Pressure — Application Case

Customer Profile

The typical setting in Chemical & Pharmaceutical is reactors, metering vessels and finished-product tanks. The measuring point is Gauge and Absolute Pressure; the focus is measuring gauge or absolute pressure to judge process state.

Key Difficulties

Conditions are highly corrosive media with solvents and crystallisation, partly in explosive atmospheres and, on top of that, corrosion plus Ex protection shortens instrument life and makes downtime costly, which a standard configuration cannot handle for long. The design therefore starts with selected by turndown, overpressure protection and diaphragm material.

Implementation

The scope ran through the pressure range: pressure solution matched to process pressure and temperature. Technically it hinges on selected by turndown, overpressure protection and diaphragm material, and on these requirements: Ex certification and GMP traceability of records.

Customer Benefit

In practice this means spotting abnormal pressure early, before equipment is damaged, which cut the workload on the site maintenance team.

Power & Energy

Power & Energy · Gauge and Absolute Pressure — Application Case

Project Background

The project covers boiler feedwater, turbine condensate and FGD/DeNOx systems. The work centres on Gauge and Absolute Pressure and the core task is measuring gauge or absolute pressure to judge process state.

Operating Challenges

The medium and duty are characterised by high temperature and pressure with both steam and saline water, and drift under high temperature and pressure, with very costly unplanned outages. So Gauge and Absolute Pressure cannot be specified generically — it calls for selected by turndown, overpressure protection and diaphragm material.

Solution

The Ainstru engineering team worked through the pressure range: pressure solution matched to process pressure and temperature. The configuration involves selected by turndown, overpressure protection and diaphragm material, with these requirements in view: compliance with power-industry codes and unit availability targets.

Results

Since start-up the system has run steadily; the practical result is spotting abnormal pressure early, before equipment is damaged.