Instrumentation · Engineering · Package · PLC
0755-82221901 sales@ainstru.com

RNO22 Signal output isolating amplifier

RNO22 Signal output isolating amplifier
Signal output isolating amplifier
The RNO22 output isolating amplifier is used to safely control active components such as control valves, actuators, I/P converters or indicators. The intrinsically safe device separates and transmits analog 0/4 to 20 mA signals and offers bidirectional HART® transparency for digital communication with smart actuators. The compact interface device with up to two galvanically isolated channels enables open- and short-circuit monitoring for reliable operation of critical equipment.
Compare

Power supplies & barrier

Measuring Principle Active barrier
Measuring principle Output isolating amplifier
Function 1-channel
2-channel
Power Supply 24 V DC
Input 0/4…20 mA / HART​
passive​
Output 0/4…20 mA / HART​
active
Certificates ATEX IECEx [Ex ia Ga], [Ex ia Da], Ex ec
UK [Ex ia Ga], [Ex ia Da], Ex ec
DNV
SIL SIL 2 SC 3
Operation DIP switch, HART
  • The RNO22 signal output isolating amplifier safely controls active components such as pneumatic converters, control valves or process displays. The intrinsically safe device transmits isolated 0/4...20 mA analog signals, supports bidirectional transparent HART® transmission mode and communicates digitally with intelligent actuators.

  • The interface module is compact and provides up to two galvanically isolated channels with line open-circuit and short-circuit monitoring, ensuring reliable operation of critical equipment.

Advantages

  • Safe and reliable control of active components in hazardous areas

  • Fast and convenient device wiring and commissioning: plug-in terminals and power supply installed via the DIN rail bus connector

  • Small, compact housing: optional dual-channel version with a width of only 12.5 mm (0.49 in), making efficient use of the space inside the control cabinet

  • Precise and reliable signal transmission

  • Monitors line open circuits and short circuits

Field of application

  • Single-channel or dual-channel signal output isolating amplifier

  • Reliable control of active components such as control valves and pneumatic converters

  • Isolated transmission of 0/4 ... 20 mA signals

  • Intrinsically safe certification [Ex ia], can be installed for use in Zone 2 explosion-protected areas

  • Can be used in safety instrumented systems up to functional safety level SIL 2 (SC 3) in accordance with IEC 61508

  • Bidirectional digital HART® communication

  • Ambient temperature range: –40...70 °C (–40...158 °F)

Spare Parts & Accessories 4

4 spare parts · click to collapse
Order codeDescription
71505292Terminal set, 2-pole, DIN rail, screwPacking unit: 9 piecesDetails
71505320Terminal set, 2-pole, DIN rail push-inPacking unit: 9 piecesDetails
71505347Flap 12.5 W25 DIN rail housingPacking unit: 5 piecesDetails
71505349Power rail connector DIN rail 12.5mmDetails

Configurator / Comparison

ConfigureEnter a product model to configure
CompareEnter the product models to compare — up to three products

Source:Endress+Hauserpublic information from the website

All documents for this model
3 documents · click to expand
BA

RNO22 English

Rev. 0120 44 pages
Preview
TI

RNO22 Chinese

Rev. 0121 12 pages
Preview
TI

RNO22 English

Rev. 0121 12 pages
Preview
Municipal Wastewater Treatment

Municipal Wastewater Treatment · Power supplies and safety barriers — Application Case

Project Overview

The site is the inlet, biological and outlet stages of a municipal plant. The customer wanted Power supplies and safety barriers properly configured on the existing plant, with the aim of supplying power and intrinsic-safety isolation to field instruments.

Technical Challenges

What actually causes trouble is high solids and corrosive fractions, with large diurnal flow swings, and effluent parameters drift and probes foul with sludge and biofilm. All of this means the Power supplies and safety barriers configuration has to involve selected by loop count, Ex rating and redundancy needs.

Configuration

Supply and installation were organised through the system components range: supplying as a full cabinet and signal-chain configuration. On site this meant selected by loop count, Ex rating and redundancy needs, checked line by line against: stable compliance with Grade 1A discharge limits and online data reporting.

Performance

After commissioning the outcome is compliant IS loops, lowering live-work risk during maintenance, and the readings are now used for process tuning.

Food & Beverage

Food & Beverage · Power supplies and safety barriers — Application Case

Site Conditions

This is a Food & Beverage customer whose plant is at dosing, pasteurising, filling and CIP stages. The main task was supplying power and intrinsic-safety isolation to field instruments.

The Problem

The difficulty lies in syrups, dairy and beverages that scale easily, under strict hygienic requirements; at the same time frequent cleaning demands instruments that withstand hot CIP/SIP caustic cycles. Specification therefore means selected by loop count, Ex rating and redundancy needs.

What We Did

We took a system components range approach — supplying as a full cabinet and signal-chain configuration. Delivery was built around selected by loop count, Ex rating and redundancy needs, with point-by-point checks on: food-safety and hygienic design per 3-A / EHEDG.

Operating Outcome

In service the system performs as intended — compliant IS loops, lowering live-work risk during maintenance, with routine maintenance falling noticeably.

Chemical & Pharmaceutical

Chemical & Pharmaceutical · Power supplies and safety barriers — Application Case

Application Context

reactors, metering vessels and finished-product tanks is a typical Chemical & Pharmaceutical duty. The project started from Power supplies and safety barriers, focusing on supplying power and intrinsic-safety isolation to field instruments.

Process Constraints

corrosion plus Ex protection shortens instrument life and makes downtime costly, and highly corrosive media with solvents and crystallisation, partly in explosive atmospheres only amplify it. The Power supplies and safety barriers specification must therefore cover selected by loop count, Ex rating and redundancy needs.

Delivery Approach

Delivery was handled as the system components range — supplying as a full cabinet and signal-chain configuration. Execution centred on selected by loop count, Ex rating and redundancy needs, together with Ex certification and GMP traceability of records.

Field Results

Operation shows the benefit clearly — compliant IS loops, lowering live-work risk during maintenance, with confidence in this measuring point improving markedly.

Power & Energy

Power & Energy · Power supplies and safety barriers — Application Case

Customer Profile

The typical setting in Power & Energy is boiler feedwater, turbine condensate and FGD/DeNOx systems. The measuring point is Power supplies and safety barriers; the focus is supplying power and intrinsic-safety isolation to field instruments.

Key Difficulties

Conditions are high temperature and pressure with both steam and saline water and, on top of that, drift under high temperature and pressure, with very costly unplanned outages, which a standard configuration cannot handle for long. The design therefore starts with selected by loop count, Ex rating and redundancy needs.

Implementation

The scope ran through the system components range: supplying as a full cabinet and signal-chain configuration. Technically it hinges on selected by loop count, Ex rating and redundancy needs, and on these requirements: compliance with power-industry codes and unit availability targets.

Customer Benefit

In practice this means compliant IS loops, lowering live-work risk during maintenance, which cut the workload on the site maintenance team.