Technical Data
CompareField tools
| Function | Universal device configuration tablet supporting multiple protocols and E+H service protocols; connects to E+H Bluetooth/WLAN field devices via modem (point-to-point), bus system or wireless (WLAN/Bluetooth) |
| Configuration | Touch-enabled configuration software supporting HART, PROFIBUS DP/PA, PROFINET, FOUNDATION Fieldbus, Modbus, IO-Link and E+H service protocols (CDI, ISS, IPC, PCP) with thousands of pre-installed drivers |
| CPU / Memory | Intel Core i5-1235; 16 GB DDR5 |
| Storage | 512 GB SSD; microSD slot (microSDXC) |
| Screen size / Resolution | 11.6" LCD multi-touch, Gorilla Glass, optical bonding, sunlight readable; 1920 x 1080 (Full HD) |
| Communication interface | 1 x Thunderbolt 4; 2 x USB 3.2 Gen 2 (Type A); WiFi 6E; Bluetooth 5.3; 4G LTE WWAN |
| Power supply | Replaceable lithium polymer battery 11.1 V DC, 3900 mAh (8 h) / 6900 mAh (15 h, optional) |
| Dimensions / Protection | 298 x 192 x 20 mm; IP64; Windows 11 LTSC |
| Application | Commissioning and maintenance of field devices in Ex Zone 2 and non-hazardous areas |
Product overview
The Field Xpert SMT70B tablet PC for device configuration enables mobile plant asset management in hazardous (Ex Zone 2) and non-hazardous areas. It is suitable for commissioning and maintenance staff to manage Endress+Hauser and third-party field instruments with a digital communication interface, and documents the progress of the work.
The tablet comes with touch-enabled device configuration software supporting HART, PROFIBUS DP/PA, PROFINET, FOUNDATION Fieldbus, Modbus, IO-Link and Endress+Hauser service protocols (CDI, ISS, IPC, PCP), with several thousand pre-installed device and communication drivers.
Benefits
- High-performance industrial tablet: 11.6" Full HD multi-touch display, Gorilla Glass, sunlight readable.
- Efficient asset management and maintenance: configure, diagnose and document devices on site.
- Mobile commissioning: supports all common fieldbus and E+H service protocols with automatic device recognition.
- Integrated Netilion ecosystem: better collaboration and productivity.
- Fast connections: WiFi 6E, Bluetooth 5.3 and 4G LTE with real-time updates.
Field of application
For commissioning, inspection and maintenance of field instruments:
- Device commissioning in Ex Zone 2
- Parameterization of third-party field devices
- Device diagnostics and maintenance documentation
Function
Field devices are connected directly via a suitable interface such as a modem (point-to-point), a bus system (point-to-bus) or a wireless connection (WLAN/Bluetooth). The configuration software is optimized for touch operation and includes thousands of pre-installed device and communication drivers for HART, PROFIBUS DP/PA, PROFINET, FOUNDATION Fieldbus, Modbus, IO-Link and E+H service protocols.
Configurator / Comparison
Manuals & Documents 4
All documents for this modelCase Studies
Municipal Wastewater Treatment · Process Measuring and Control Instrument — Application Case
Application Context
the inlet, biological and outlet stages of a municipal plant is a typical Municipal Wastewater Treatment duty. The project started from Process Measuring and Control Instrument, focusing on measurement, control and recording for process loops.
Process Constraints
effluent parameters drift and probes foul with sludge and biofilm, and high solids and corrosive fractions, with large diurnal flow swings only amplify it. The Process Measuring and Control Instrument specification must therefore cover configured by input type, loop count and communication.
Delivery Approach
Delivery was handled as the system components range — supplying as a full cabinet and signal-chain configuration. Execution centred on configured by input type, loop count and communication, together with stable compliance with Grade 1A discharge limits and online data reporting.
Field Results
Operation shows the benefit clearly — configured on site, cutting back-and-forth during system commissioning, with confidence in this measuring point improving markedly.
Municipal Wastewater Treatment · data manager — Application Case
Site Conditions
This is a Municipal Wastewater Treatment customer whose plant is at the inlet, biological and outlet stages of a municipal plant. The main task was centralised data acquisition, storage and forwarding to management platforms.
The Problem
The difficulty lies in high solids and corrosive fractions, with large diurnal flow swings; at the same time effluent parameters drift and probes foul with sludge and biofilm. Specification therefore means selected by channel count, storage depth and forwarding protocol.
What We Did
We took a system components range approach — supplying as a full cabinet and signal-chain configuration. Delivery was built around selected by channel count, storage depth and forwarding protocol, with point-by-point checks on: stable compliance with Grade 1A discharge limits and online data reporting.
Operating Outcome
In service the system performs as intended — automatic backfill after outages, greatly improving data completeness, with routine maintenance falling noticeably.
Municipal Wastewater Treatment · Power supplies and safety barriers — Application Case
Project Overview
The site is the inlet, biological and outlet stages of a municipal plant. The customer wanted Power supplies and safety barriers properly configured on the existing plant, with the aim of supplying power and intrinsic-safety isolation to field instruments.
Technical Challenges
What actually causes trouble is high solids and corrosive fractions, with large diurnal flow swings, and effluent parameters drift and probes foul with sludge and biofilm. All of this means the Power supplies and safety barriers configuration has to involve selected by loop count, Ex rating and redundancy needs.
Configuration
Supply and installation were organised through the system components range: supplying as a full cabinet and signal-chain configuration. On site this meant selected by loop count, Ex rating and redundancy needs, checked line by line against: stable compliance with Grade 1A discharge limits and online data reporting.
Performance
After commissioning the outcome is compliant IS loops, lowering live-work risk during maintenance, and the readings are now used for process tuning.
Municipal Wastewater Treatment · Gateways and modems — Application Case
Project Background
The project covers the inlet, biological and outlet stages of a municipal plant. The work centres on Gateways and modems and the core task is converting field data into remote transmission channels.
Operating Challenges
The medium and duty are characterised by high solids and corrosive fractions, with large diurnal flow swings, and effluent parameters drift and probes foul with sludge and biofilm. So Gateways and modems cannot be specified generically — it calls for configured by protocol, tag count and carrier network conditions.
Solution
The Ainstru engineering team worked through the system components range: supplying as a full cabinet and signal-chain configuration. The configuration involves configured by protocol, tag count and carrier network conditions, with these requirements in view: stable compliance with Grade 1A discharge limits and online data reporting.
Results
Since start-up the system has run steadily; the practical result is remote sites can report back, making unattended operation possible.