Basic thermometers offer reliable temperature measurement performance with basic sensor technology, a standard extension neck and a fixed, non-replaceable insert for use in non-hazardous areas. The devices are available with optional Bluetooth®-enabled head transmitters with 4 to 20 mA output or HART® communication, providing enhanced measurement accuracy and reliability compared to directly wired sensors.
Compare

Thermometer

Measuring Principle Resistance Temperature Detector
Characteristic / Application Basic technologie
metric style
universal range of application
direct process contact
Thermowell / protection tube without, direct process contact
Insert / probe Basis Sensortechnologie
Outer diameter protection tube / Insert Insert:
6,0 mm
Max. immersion length on request up to 1.000,0 mm (39'')
Material protection tube/ thermowell Insert Material:
316L (1.4404)
Alloy 600 (2.4816)
Process connection Thread:
G1/2", G1/4"
NPT1/2"
M18x1.5, M20x1.5
Cap-nut:
G1/2", G3/4"
Compression fitting, also spring load:
NPT1/2", G1/2"
Tip shape straight
Operating temperature range Basic PT100 TF:
-50 °C …200 °C
(-58 °F …392 °F)
Typ K:
max. 1.100 °C
(max. 2.012 °F)
Max. process pressure (static) depending on the configuration
Accuracy Class A acc. to IEC 60751
Class B acc. to IEC 60751
Class standard acc. to ASTM E230
Class 2 acc. to IEC 60584-2
Response time t90 around 17 s
depending on configuration
Integration head transmitter yes (4 … 20 mA; HART)

Basic technology, utility version, suitable for all standard applications
Application
•Universal range
•For use in non-hazardous areas
•Measuring range: –50 to +650°C (–58 to +1202°F)
•Pressure range up to 50 bar (725.2 psi)
•Degree of protection: up to IP 68

Transmitter
Endress + Hauser transmitters offer higher accuracy and reliability
compared with directly connected sensors. Easily customized by selecting one of the following
output and communication protocols:
Analog output 4 to 20 mA, HART®

Benefits
•Excellent value for money with fast global delivery
•User-friendly product selection, smart design, easy maintenance
•Wide range of process connections
•Bluetooth® connection (optional)

 

Spare Parts & Accessories 32

32 spare parts · click to expand
Order codeDescription
TA30A-接线盒 TA30ARetainer for terminal block or head transmitter + optional display. Cover: low, hinged, optional window. Material: aluminium. Coating: polyester powder-coating. Colour: body blue, cover grey. Ambient temp.: -50...150 oC (housing). Protection: IP66/68, NEMA 4X (housing).Enquire
71182602密封5x O-ring 3.69x1.78 5x 0-ring 74.7x2.75Enquire
TA20AB-接线盒 TA20ABTerminal head for temperature assemblies, simple execution, lid fixed by screws. Inner geometry acc. to DIN EN 50446.Enquire
TA30EB-Terminal Head TA30EBRetainer for terminal block or head transmitter + optional display. Cover: low, threaded, optional window. Material: Aluminum. Coating: Polyester powder-coating. Colour: body blue, cover grey. Ambient temp.: -50...+150oC (housing). Protection: IP66/68, NEMA 4X (housing).Enquire
XPT0002-插接头Enquire
TMT31-F+ 温度变送器 TMT312-wire temperature transmitter. Single sensor input. Application: RTD/TC. Factory setup w/o additional specification: Pt100, 4-wire, 0...+100oC, presetting failure current low. Consider additional marine certificate requirements on application side.Enquire
TMT36-F+ IO-Link 温度变送器 TMT362-wire temperature transmitter. Single sensor input. Application: RTD. Factory setup w/o additional specification: Pt100, 4-wire, oC. Mounting: head form B, DIN EN50446.Enquire
TMT71-温度变送器TMT712-wire temperature transmitter. Single universal sensor input. Galvanic isolation 2kV (input/output). Application: RTD, TC, Ohm and mV. Factory setup w/o additional specification:Pt100, 4-wire, 0...+100oC.Enquire
TMT72-温度变送器TMT722-wire temperature transmitter. Single universal sensor input. Galvanic isolation 2kV (input/output). Application: RTD, TC, Ohm and mV. Factory setup w/o additional specification: Pt100, 4-wire, 0...+100oCEnquire
71044061设备包2x screws, 2x springs, 2x spring rings, 1x sealing CDI-connectorEnquire
TS111-iTHERM TS111 芯子Replaceable insert acc. IEC 60751. Metric version acc. DIN 43735. ::Fastest response times for optimal process control through iTHERM QuickSens. ::Maximum robustness for highest process safety through iTHERM StrongSens.Enquire
71111513陶瓷接线端Enquire
71111514陶瓷接线端Enquire
71111515陶瓷接线端Enquire
TK40-iTHERM TK40 卡套螺纹Weld-in compression fitting with hygienic design. For applications in the food/ beverages and pharmaceutical industries.Enquire
XPT0001-Spare Part Kit Sealing for TK40 XPT0001delivery: 5 parts per kitEnquire
71438350Spring-loaded compr. fitting G1/2 compl.d6mm, loadedEnquire
71438349Spring-loaded compr. fitt. NPT1/2 compl.d6mm, loadedEnquire
TXU10-仪表调试包 TXU10用于可以PC编程调试的设备 程序设置+用于带USB接口的PC的连接线Enquire
FXA195-通讯接口 FXA195Modem to connect HART field devices to a computer via USB. Commissioning of field devices with software tool. :: To connect to a intrinsically safe signal circuit. :: SIL2, IEC61508.Enquire
SFP20-FieldPort SFP20 USB/IO-Link调制解调器IO-Link USB interface FieldPort SFP20 for commissioning and maintaining of IO- Link measuring devicesEnquire
71460208FieldPort SFP20 专用M12接头Cable to connect the FieldPort SFP20 with an IO-Link deviceEnquire
71438343Spare parts kit o-ring (silicon) 71x3Packing unit: 5 piecesEnquire
71586372Spare parts kit gasket ring D21/d3 Neop.Packung unit: 3 piecesEnquire
71586370Spare parts kit gasket ring D21/d3 VitonPackung unit: 3 piecesEnquire
71586366Spare parts kit gasket ring D21/d6 Neop.Packung unit: 3 piecesEnquire
71586353Spare parts kit gasket ring D21/d6 VitonPackung unit: 3 piecesEnquire
71367427垫片Packing unit: 10 piecesEnquire
71367420铜密封圈Packing unit: 10 piecesEnquire
71367414铜密封圈Packing unit: 10 piecesEnquire
71438347Spare parts kit copper ring M18Packing unit: 10 piecesEnquire
71367425铜密封圈Packing unit: 10 piecesEnquire

Configurator / Comparison

ConfigureEnter a product model to configure
CompareEnter the product models to compare — up to three products

   

   

 

 

   

Measuring Principle Video

Click to play

Source:Endress+Hauserwebsite public information

18 models · click to expand
Model Name
TM101-1ED7/0 RTD thermometer
TM101-AACCA4GA0A1A1 RTD thermometer
TM101-AACCA8BA2H1A1 RTD thermometer
TM101-AACCA6BA2H1A1 RTD thermometer
TM101-AACCA4GA2C5A1 RTD thermometer
TM101-AACCA8GA0A1A1 RTD thermometer
TM101-AACCA4GC2A1A1 RTD thermometer
TM101-AAHBA6AH3A5A1 RTD thermometer
TM101-AACCA4BA2H1A1 RTD thermometer
TM101-8769/160 RTD thermometer
TM101-8769/139 RTD thermometer
TM101-83D0/142 RTD thermometer
TM101-89X1/115 RTD thermometer
TM101-1J39/0 iTHERM ModuLine TM101
TM101-1AQ3/101 RTD thermometer
TM101-2E39/0 RTD thermometer
TM101-AACCA4BA0A1A1 iTHERM ModuLine TM101
TM101-8QD9/101 RTD thermometer
All documents for this model
4 documents · click to expand
BA

BA iTHERM ModuLine工业温度计 Chinese

Rev. 0325 24 pages
Preview
BA

BA iTHERM ModuLine thermometer English

Rev. 0325 28 pages
Preview
TI

TI iTHERM ModuLine TM101 Chinese

Rev. 0525 28 pages
Preview
TI

TI iTHERM ModuLine TM101 English

Rev. 0525 28 pages
Preview
Municipal Wastewater Treatment

Municipal Wastewater Treatment · thermistor — Application Case

Project Overview

The site is the inlet, biological and outlet stages of a municipal plant. The customer wanted thermistor properly configured on the existing plant, with the aim of high-accuracy temperature measurement with platinum resistance elements.

Technical Challenges

What actually causes trouble is high solids and corrosive fractions, with large diurnal flow swings, and effluent parameters drift and probes foul with sludge and biofilm. All of this means the thermistor configuration has to involve choosing Pt100 or Pt1000 by accuracy class, wiring system and insertion depth.

Configuration

Supply and installation were organised through the temperature range: temperature solution matched to measuring point and response needs. On site this meant choosing Pt100 or Pt1000 by accuracy class, wiring system and insertion depth, checked line by line against: stable compliance with Grade 1A discharge limits and online data reporting.

Performance

After commissioning the outcome is clear accuracy advantage at low temperatures, giving tighter process windows, and the readings are now used for process tuning.

Food & Beverage

Food & Beverage · thermistor — Application Case

Site Conditions

This is a Food & Beverage customer whose plant is at dosing, pasteurising, filling and CIP stages. The main task was high-accuracy temperature measurement with platinum resistance elements.

The Problem

The difficulty lies in syrups, dairy and beverages that scale easily, under strict hygienic requirements; at the same time frequent cleaning demands instruments that withstand hot CIP/SIP caustic cycles. Specification therefore means choosing Pt100 or Pt1000 by accuracy class, wiring system and insertion depth.

What We Did

We took a temperature range approach — temperature solution matched to measuring point and response needs. Delivery was built around choosing Pt100 or Pt1000 by accuracy class, wiring system and insertion depth, with point-by-point checks on: food-safety and hygienic design per 3-A / EHEDG.

Operating Outcome

In service the system performs as intended — clear accuracy advantage at low temperatures, giving tighter process windows, with routine maintenance falling noticeably.

Chemical & Pharmaceutical

Chemical & Pharmaceutical · thermistor — Application Case

Application Context

reactors, metering vessels and finished-product tanks is a typical Chemical & Pharmaceutical duty. The project started from thermistor, focusing on high-accuracy temperature measurement with platinum resistance elements.

Process Constraints

corrosion plus Ex protection shortens instrument life and makes downtime costly, and highly corrosive media with solvents and crystallisation, partly in explosive atmospheres only amplify it. The thermistor specification must therefore cover choosing Pt100 or Pt1000 by accuracy class, wiring system and insertion depth.

Delivery Approach

Delivery was handled as the temperature range — temperature solution matched to measuring point and response needs. Execution centred on choosing Pt100 or Pt1000 by accuracy class, wiring system and insertion depth, together with Ex certification and GMP traceability of records.

Field Results

Operation shows the benefit clearly — clear accuracy advantage at low temperatures, giving tighter process windows, with confidence in this measuring point improving markedly.

Power & Energy

Power & Energy · thermistor — Application Case

Customer Profile

The typical setting in Power & Energy is boiler feedwater, turbine condensate and FGD/DeNOx systems. The measuring point is thermistor; the focus is high-accuracy temperature measurement with platinum resistance elements.

Key Difficulties

Conditions are high temperature and pressure with both steam and saline water and, on top of that, drift under high temperature and pressure, with very costly unplanned outages, which a standard configuration cannot handle for long. The design therefore starts with choosing Pt100 or Pt1000 by accuracy class, wiring system and insertion depth.

Implementation

The scope ran through the temperature range: temperature solution matched to measuring point and response needs. Technically it hinges on choosing Pt100 or Pt1000 by accuracy class, wiring system and insertion depth, and on these requirements: compliance with power-industry codes and unit availability targets.

Customer Benefit

In practice this means clear accuracy advantage at low temperatures, giving tighter process windows, which cut the workload on the site maintenance team.