TMR31 Compact Thermometer

TMR31 Compact Thermometer
Compact Thermometer TMR31
Configurable Models 20 models
With cost efficiency, optimal use of space, reliable operation, easy installation and commissioning the TMR31 fulfills the requirements of modern process measurement technology. Vibration-proof integrated thin-film sensors guarantee highest operational safety at the fastest response times.
Compare

Thermometer

Measuring Principle Resistance Temperature Detector
Characteristic / Application metric style
compact temperature probe
fast response time
threaded process connection
with or without neck
Thermowell / protection tube without (not intended to use with thermowell)
Insert / probe pipe version, isolated wires, not flexible
Outer diameter protection tube / Insert 4,00 mm (0,16")
6,00 mm (0,24'')
Max. immersion length on request up to 600,00 mm (23,62'')
Material protection tube/ thermowell 1.4404 (316L)
Process connection male thread:
G1/4"
G1/2"
NPT1/4"
NPT1/2"
M14x1.5
M18x1.5
BSPT R1/2"
Tip shape straight
Surface roughness Ra 0,8 μm (32 μin.)
Operating temperature range PT 100:
-50 °C ...200 °C
(-58 °F ...392 °F)
Max. process pressure (static) at 20 °C: 100 bar (1.450 psi)
Accuracy class A acc. to IEC 60751
Response time t50 = 1 s
t90 = 2 s
Integration head transmitter no (4…20mA Signal)
Certification Marine approval
UL 3111-1

The TMR31 offers excellent value for money, saves installation space, is simple to install and commission, operates reliably and meets the requirements of modern measurement technology. The built-in vibration-resistant thin-film sensor guarantees the fastest response time and the highest operational safety.

 

Advantages

Compact design, fully stainless steel construction

Very short response time

Small insertion depth for precise measurement

4-wire Pt100 output or PC-programmable transmitter with 4 to 20 mA output

Device configuration and visualization using the free ReadWin® 2000 PC operating software

Displays sensor open-circuit or short-circuit fault information, adjustable according to NAMUR NE43

Marine approval

Spare Parts & Accessories 15

15 spare parts · click to collapse
Order codeDescription
71367414Copper sealing ringPacking unit: 10 piecesDetails
51007599SealSealing cone G1/2Details
71535690Welded socket with collar d6 PEEK + screwDetails
71535691Welded socket with collar, d6, PEEK, without screwDetails
TA50-Mounting parts, compression fitting TA50Screw in.Enquire
71744221Spare part kit TA50-GB/NB/HB/PB/BB/CB/DBPacking unit: 10 pieces, d=6.1mm. Material: 316/1.4401.Details
71744222Spare part kit TA50-GP/NP/HP/PP/BP/CP/DPPacking unit: 10 pieces, d=6.1mm. Material: PTFE.Details
TXU10-Instrument Commissioning Kit TXU10用于可以PC编程调试的设备 程序设置+用于带USB接口的PC的连接线Enquire
51007657TXU10 Upgrade AdapterAdapter Upgrade TXU10Details
RXU10-Data Manager Accessory RXU10Enquire
71535693M12 elbow plug ready for cable, IP67, PG7Details
71589963Cable connector M12 IP69k 5mDetails
510051485 m cable, 4x0.34 mm², PVC5米线缆,4x0.34m㎡,PVC M12x1 拐角航空插头, 螺栓 Cu Sn/NI,IP67Details
71217708Core wire set 4p D18 IP69KPVC cable, 4x0.34mm2 (22 AWG) with M12x1 coupling nut made of epoxy coated Zinc, straight socket contact, screw plug, 5m (16.4ft).Details
RIA15-F+ Loop-Powered Indicator RIA15单通道,无需单独供电 回路供电 5位液晶显示 可选HART通信 可选背光显示 棒状图 10%分辨率Enquire

Configurator / Comparison

ConfigureEnter a product model to configure
CompareEnter the product models to compare — up to three products

   

   

 

 

   

Measuring principle video

Click to play
70 models · click to collapse
All documents for this model
7 documents · click to expand
BA

BA 紧凑型温度计 TMR31, TMR35 Chinese

Rev. 2125 44 pages
Preview
BA

BA Compact thermometer TMR31, TMR35 English

Rev. 2125 44 pages
Preview
BA

ReadWin® Quick Setup English

15 pages
Preview
TI

TI 焊接接头、过程转接头和法兰 Chinese

Rev. 2726 130 pages
Preview
TI

TI 紧凑型温度计TMR31, TMR35 Chinese

Rev. 2325 28 pages
Preview
TI

TI Weld-in adapter, process adapter and flanges English

Rev. 2726 132 pages
Preview
TI

TI Compact thermometer TMR31, TMR35 English

Rev. 2325 28 pages
Preview
Municipal Wastewater Treatment

Municipal Wastewater Treatment · thermistor — Application Case

Project Overview

The site is the inlet, biological and outlet stages of a municipal plant. The customer wanted thermistor properly configured on the existing plant, with the aim of high-accuracy temperature measurement with platinum resistance elements.

Technical Challenges

What actually causes trouble is high solids and corrosive fractions, with large diurnal flow swings, and effluent parameters drift and probes foul with sludge and biofilm. All of this means the thermistor configuration has to involve choosing Pt100 or Pt1000 by accuracy class, wiring system and insertion depth.

Configuration

Supply and installation were organised through the temperature range: temperature solution matched to measuring point and response needs. On site this meant choosing Pt100 or Pt1000 by accuracy class, wiring system and insertion depth, checked line by line against: stable compliance with Grade 1A discharge limits and online data reporting.

Performance

After commissioning the outcome is clear accuracy advantage at low temperatures, giving tighter process windows, and the readings are now used for process tuning.

Food & Beverage

Food & Beverage · thermistor — Application Case

Site Conditions

This is a Food & Beverage customer whose plant is at dosing, pasteurising, filling and CIP stages. The main task was high-accuracy temperature measurement with platinum resistance elements.

The Problem

The difficulty lies in syrups, dairy and beverages that scale easily, under strict hygienic requirements; at the same time frequent cleaning demands instruments that withstand hot CIP/SIP caustic cycles. Specification therefore means choosing Pt100 or Pt1000 by accuracy class, wiring system and insertion depth.

What We Did

We took a temperature range approach — temperature solution matched to measuring point and response needs. Delivery was built around choosing Pt100 or Pt1000 by accuracy class, wiring system and insertion depth, with point-by-point checks on: food-safety and hygienic design per 3-A / EHEDG.

Operating Outcome

In service the system performs as intended — clear accuracy advantage at low temperatures, giving tighter process windows, with routine maintenance falling noticeably.

Chemical & Pharmaceutical

Chemical & Pharmaceutical · thermistor — Application Case

Application Context

reactors, metering vessels and finished-product tanks is a typical Chemical & Pharmaceutical duty. The project started from thermistor, focusing on high-accuracy temperature measurement with platinum resistance elements.

Process Constraints

corrosion plus Ex protection shortens instrument life and makes downtime costly, and highly corrosive media with solvents and crystallisation, partly in explosive atmospheres only amplify it. The thermistor specification must therefore cover choosing Pt100 or Pt1000 by accuracy class, wiring system and insertion depth.

Delivery Approach

Delivery was handled as the temperature range — temperature solution matched to measuring point and response needs. Execution centred on choosing Pt100 or Pt1000 by accuracy class, wiring system and insertion depth, together with Ex certification and GMP traceability of records.

Field Results

Operation shows the benefit clearly — clear accuracy advantage at low temperatures, giving tighter process windows, with confidence in this measuring point improving markedly.

Power & Energy

Power & Energy · thermistor — Application Case

Customer Profile

The typical setting in Power & Energy is boiler feedwater, turbine condensate and FGD/DeNOx systems. The measuring point is thermistor; the focus is high-accuracy temperature measurement with platinum resistance elements.

Key Difficulties

Conditions are high temperature and pressure with both steam and saline water and, on top of that, drift under high temperature and pressure, with very costly unplanned outages, which a standard configuration cannot handle for long. The design therefore starts with choosing Pt100 or Pt1000 by accuracy class, wiring system and insertion depth.

Implementation

The scope ran through the temperature range: temperature solution matched to measuring point and response needs. Technically it hinges on choosing Pt100 or Pt1000 by accuracy class, wiring system and insertion depth, and on these requirements: compliance with power-industry codes and unit availability targets.

Customer Benefit

In practice this means clear accuracy advantage at low temperatures, giving tighter process windows, which cut the workload on the site maintenance team.