Instrumentation · Engineering · Package · PLC
0755-82221901 sales@ainstru.com

TSC310 Thermocouple sensor, wire probe

TSC310 Thermocouple sensor, wire probe
Thermocouple sensor, wire probe
The thermocouple (TC) cable probe is easy to install and provide a high operational safety due to reliable and accurate temperature measurement in common processes. The probe is specially suited to temperature measurement in machinery, laboratory equipment and plants in gaseous or liquid medium like air, water, oil, etc. Without additional thermowell the probe sheath is directly in contact with the process medium. This enables to detect rapid temperature changes fast and accurate.
Compare

Thermometer

Measuring Principle Thermocouple
Characteristic / Application metric style
cable probe
suitable for hazardous areas
process connection as compression fitting
Thermowell / protection tube without (not intended to use with thermowell)
Insert / probe mineral insulated (MI), flexible
Outer diameter protection tube / Insert 2,0 mm (0,08'')
3,0 mm (0,12'')
4,5 mm (0,18'')
6,0 mm (0,24'')
Max. immersion length on request up to 100.000,00 mm (3.937,01'')
Material protection tube/ thermowell 1.4401 (316)
Alloy 600 (2.4816)
Process connection compression fitting:
G1/4
G3/8
G1/2
G1/8
NPT1/4
NPT1/2
NPT1/8
NPT3/8
Tip shape straight
Operating temperature range Type K:
max. 1.100 °C
(max. 2.012 °F)
Type J:
max. 750 °C
(max. 1.382 °F)
Max. process pressure (static) at 20 °C: 25 bar (363 psi)
Accuracy class 2 acc. to IEC 60584
Response time t50 = 1 s
t90 = 2 s
Integration head transmitter no
Ex - approvals ATEX Ex ia, Ex nA
IECEx Ex ia
NEPSI Ex ia
EAC Ex ia
UKCA Ex ia, Ex nA, Ex tc
Certification Gost Metrology

The thermocouple probe is easy to install and measures temperature reliably and accurately in general process applications, providing high operational safety. The probe is particularly suitable for measuring gaseous and liquid media such as air, water and oil in mechanical equipment, laboratory instruments and plants. The probe housing comes into direct contact with the process medium without an additional thermowell and detects temperature changes quickly and accurately.

 

Advantages

Insertion length to customer requirements and various process connections for high flexibility

Fast response time

Various thermocouples in accordance with DIN EN 60584 and ASTM E230/ANSI MC96.1: type J (Fe-CuNi), type K (NiCr-Ni)

Can be used in hazardous locations: intrinsically safe (Ex ia) and non-sparking (Ex nA)

NEPSI (Ex ia) approval

Spare Parts & Accessories 3

3 spare parts · click to collapse
Order codeDescription
TA50-Mounting parts, compression fitting TA50Screw in.Enquire
71744217Spare part kit TA50-QB/FBPacking unit: 10 pieces, d=3mm. Material: 316/1.4401.Details
71744218Spare part kit TA50-QP/FPPacking unit: 10 pieces, d=3mm. Material: PTFE.Details

Configurator / Comparison

ConfigureEnter a product model to configure
CompareEnter the product models to compare — up to three products

   

   

 

 

Accessories / Spare parts

 

Source:Endress+Hauserpublic information from the website

Measuring principle video

Click to play
All documents for this model
5 documents · click to expand
TI

技术资料 Omnigrad T TSC310 Chinese

Rev. 0111 12 pages
Preview
TI

Technical information Omnigrad T TSC310 English

Rev. 1310 12 pages
Preview
TI

TSC310 English

Rev. 0220 12 pages
Preview
TI

Technical information Omnigrad T TSC310 English

Rev. 0111 12 pages
Preview
TI

Technical Information English

12 pages
Preview
Municipal Wastewater Treatment

Municipal Wastewater Treatment · thermocouples — Application Case

Project Background

The project covers the inlet, biological and outlet stages of a municipal plant. The work centres on thermocouples and the core task is high-temperature measurement with thermocouples.

Operating Challenges

The medium and duty are characterised by high solids and corrosive fractions, with large diurnal flow swings, and effluent parameters drift and probes foul with sludge and biofilm. So thermocouples cannot be specified generically — it calls for choosing the type by temperature limit, atmosphere and response speed.

Solution

The Ainstru engineering team worked through the temperature range: temperature solution matched to measuring point and response needs. The configuration involves choosing the type by temperature limit, atmosphere and response speed, with these requirements in view: stable compliance with Grade 1A discharge limits and online data reporting.

Results

Since start-up the system has run steadily; the practical result is strong high-temperature capability, measuring furnace temperatures directly.

Food & Beverage

Food & Beverage · thermocouples — Application Case

Project Overview

The site is dosing, pasteurising, filling and CIP stages. The customer wanted thermocouples properly configured on the existing plant, with the aim of high-temperature measurement with thermocouples.

Technical Challenges

What actually causes trouble is syrups, dairy and beverages that scale easily, under strict hygienic requirements, and frequent cleaning demands instruments that withstand hot CIP/SIP caustic cycles. All of this means the thermocouples configuration has to involve choosing the type by temperature limit, atmosphere and response speed.

Configuration

Supply and installation were organised through the temperature range: temperature solution matched to measuring point and response needs. On site this meant choosing the type by temperature limit, atmosphere and response speed, checked line by line against: food-safety and hygienic design per 3-A / EHEDG.

Performance

After commissioning the outcome is strong high-temperature capability, measuring furnace temperatures directly, and the readings are now used for process tuning.

Chemical & Pharmaceutical

Chemical & Pharmaceutical · thermocouples — Application Case

Site Conditions

This is a Chemical & Pharmaceutical customer whose plant is at reactors, metering vessels and finished-product tanks. The main task was high-temperature measurement with thermocouples.

The Problem

The difficulty lies in highly corrosive media with solvents and crystallisation, partly in explosive atmospheres; at the same time corrosion plus Ex protection shortens instrument life and makes downtime costly. Specification therefore means choosing the type by temperature limit, atmosphere and response speed.

What We Did

We took a temperature range approach — temperature solution matched to measuring point and response needs. Delivery was built around choosing the type by temperature limit, atmosphere and response speed, with point-by-point checks on: Ex certification and GMP traceability of records.

Operating Outcome

In service the system performs as intended — strong high-temperature capability, measuring furnace temperatures directly, with routine maintenance falling noticeably.

Power & Energy

Power & Energy · thermocouples — Application Case

Application Context

boiler feedwater, turbine condensate and FGD/DeNOx systems is a typical Power & Energy duty. The project started from thermocouples, focusing on high-temperature measurement with thermocouples.

Process Constraints

drift under high temperature and pressure, with very costly unplanned outages, and high temperature and pressure with both steam and saline water only amplify it. The thermocouples specification must therefore cover choosing the type by temperature limit, atmosphere and response speed.

Delivery Approach

Delivery was handled as the temperature range — temperature solution matched to measuring point and response needs. Execution centred on choosing the type by temperature limit, atmosphere and response speed, together with compliance with power-industry codes and unit availability targets.

Field Results

Operation shows the benefit clearly — strong high-temperature capability, measuring furnace temperatures directly, with confidence in this measuring point improving markedly.