Instrumentation · Engineering · Package · PLC
0755-82221901 sales@ainstru.com

TMT142C ThermocoupleDiscontinued

TMT142C Thermocouple
Thermocouple TMT142CDiscontinued
Endress+Hauser TMT142C
The robust thermometer is designed for use in demanding and safety relevant applications e.g. in the Chemical, Oil & Gas and Energy industry. The thermometer fulfills the corresponding safety requirements due to various certificates and tests. The use of a transmitter leads to higher accuracy and reliability in comparison to directly wired sensors.
Compare

Thermometer

Measuring Principle
Characteristic / Application US style
modular temperature assembly
for heavy duty applications
suitable for hazardous areas
threaded process connection
to use with thermowell
backlit display
Thermowell / protection tube to use with thermowell
Insert / probe mineral insulated (MI), flexible
Outer diameter protection tube / Insert Not defined
Max. immersion length on request up to 30.000,00 mm (1.181,10'')
Material protection tube/ thermowell Not defined
Optional coating Not defined
Process connection male thread:
G1/2"
NPT1/2"
NPT3/4"
union nut:
NPT1/2"
M24x1.5
Tip shape straight
Operating temperature range Type K:
-40 °C ...800 °C
(-40 °F ...1.472 °F)
Type J:
-40 °C ... 750 °C
(-40 °F ...1.382 °F)
Max. process pressure (static) depending on thermowell
Accuracy class 1 acc. to IEC 60584
class 2 acc. to IEC 60584
Response time depending on configuration
t50 = 3 s
t90 = 7 s
Integration head transmitter yes (4 … 20 mA; HART; PROFIBUS PA; FOUNDATION FIELDBUS)
Ex - approvals ATEX II
Explosion proof

A specially designed, durable thermometer for safety-related, harsh applications in the chemical, oil, gas and energy industries. The thermometer has been extensively tested and fully approved to meet the relevant safety requirements. Using a temperature transmitter provides higher measurement accuracy and reliability than a directly wired sensor.

 

Advantages

Dual-compartment housing

Backlit display showing enlarged measured value, bar graph and fault information

2 kV galvanic isolation (sensor input to output)

Standard thermowell connection offering various threaded connections

Replaceable thermocouple working element with an insulated tube

Approved for use in hazardous areas: intrinsically safe (Ex ia), flameproof (Ex d), non-sparking (Ex nA)

Aluminum or stainless steel device housing, degree of protection IP67, NEMA 4x

Spare Parts & Accessories 17

17 spare parts · click to collapse
Order codeDescription
FXA195-Communication interface FXA195Modem to connect HART field devices to a computer via USB. Commissioning of field devices with software tool. :: To connect to a intrinsically safe signal circuit. :: SIL2, IEC61508.Enquire
TMT142G-Housing TMT142GHousing TMT142GEnquire
71502617O-ring 88x3 HNBR 70° Shore PTFE_5pcsPacking unit: 5 piecesDetails
71502941O-Ring 18.77x1.78 HNBR 70° Shore PTFEPacking unit: 10 piecesDetails
TMT142X-Spare Part TMT142XSpare parts TMT142XEnquire
51004948front cover latch pinScrew, washer, spring washerDetails
51006845cable glandCable gland NPT 1/2, D4-8.5, IP68Details
510043871/2 NPT to M20x1.5 adapterAdapter M20x1,5/NPT1/2" cable entryDetails
51004915M24x1.5 to M20x1.5 adapterAdapter M20x1.5 exter./M24x1.5 intern.VADetails
51007995mounting bracketMounting bracket SS316L, tube 1,5-3"Details
71310423Display housing fixing kit (3 pcs)Details
71525620Blind plug M20x1.5 Ex-d + O-ring, aluminiumDetails
71525622Blind plug M20x1.5 Ex-d + O-ring V4ADetails
71525621Blind plug G1/2 Ex-d + o-ring, AluDetails
71525623Blind plug G1/2 Ex-d + O-ring V4ADetails
51006888blind coverDetails
51004490blind coverDetails

Configurator / Comparison

ConfigureEnter a product model to configure
CompareEnter the product models to compare — up to three products

   

   

 

 

Source:Endress+Hauserwebsite public information

Measuring principle video

Click to play
All documents for this model
2 documents · click to expand
TI

技术资料 Omnigrad S TMT142C Chinese

Rev. 0206 16 pages
Preview
TI

Technical information TMT142C English

16 pages
Preview
Municipal Wastewater Treatment

Municipal Wastewater Treatment · thermocouples — Application Case

Project Background

The project covers the inlet, biological and outlet stages of a municipal plant. The work centres on thermocouples and the core task is high-temperature measurement with thermocouples.

Operating Challenges

The medium and duty are characterised by high solids and corrosive fractions, with large diurnal flow swings, and effluent parameters drift and probes foul with sludge and biofilm. So thermocouples cannot be specified generically — it calls for choosing the type by temperature limit, atmosphere and response speed.

Solution

The Ainstru engineering team worked through the temperature range: temperature solution matched to measuring point and response needs. The configuration involves choosing the type by temperature limit, atmosphere and response speed, with these requirements in view: stable compliance with Grade 1A discharge limits and online data reporting.

Results

Since start-up the system has run steadily; the practical result is strong high-temperature capability, measuring furnace temperatures directly.

Food & Beverage

Food & Beverage · thermocouples — Application Case

Project Overview

The site is dosing, pasteurising, filling and CIP stages. The customer wanted thermocouples properly configured on the existing plant, with the aim of high-temperature measurement with thermocouples.

Technical Challenges

What actually causes trouble is syrups, dairy and beverages that scale easily, under strict hygienic requirements, and frequent cleaning demands instruments that withstand hot CIP/SIP caustic cycles. All of this means the thermocouples configuration has to involve choosing the type by temperature limit, atmosphere and response speed.

Configuration

Supply and installation were organised through the temperature range: temperature solution matched to measuring point and response needs. On site this meant choosing the type by temperature limit, atmosphere and response speed, checked line by line against: food-safety and hygienic design per 3-A / EHEDG.

Performance

After commissioning the outcome is strong high-temperature capability, measuring furnace temperatures directly, and the readings are now used for process tuning.

Chemical & Pharmaceutical

Chemical & Pharmaceutical · thermocouples — Application Case

Site Conditions

This is a Chemical & Pharmaceutical customer whose plant is at reactors, metering vessels and finished-product tanks. The main task was high-temperature measurement with thermocouples.

The Problem

The difficulty lies in highly corrosive media with solvents and crystallisation, partly in explosive atmospheres; at the same time corrosion plus Ex protection shortens instrument life and makes downtime costly. Specification therefore means choosing the type by temperature limit, atmosphere and response speed.

What We Did

We took a temperature range approach — temperature solution matched to measuring point and response needs. Delivery was built around choosing the type by temperature limit, atmosphere and response speed, with point-by-point checks on: Ex certification and GMP traceability of records.

Operating Outcome

In service the system performs as intended — strong high-temperature capability, measuring furnace temperatures directly, with routine maintenance falling noticeably.

Power & Energy

Power & Energy · thermocouples — Application Case

Application Context

boiler feedwater, turbine condensate and FGD/DeNOx systems is a typical Power & Energy duty. The project started from thermocouples, focusing on high-temperature measurement with thermocouples.

Process Constraints

drift under high temperature and pressure, with very costly unplanned outages, and high temperature and pressure with both steam and saline water only amplify it. The thermocouples specification must therefore cover choosing the type by temperature limit, atmosphere and response speed.

Delivery Approach

Delivery was handled as the temperature range — temperature solution matched to measuring point and response needs. Execution centred on choosing the type by temperature limit, atmosphere and response speed, together with compliance with power-industry codes and unit availability targets.

Field Results

Operation shows the benefit clearly — strong high-temperature capability, measuring furnace temperatures directly, with confidence in this measuring point improving markedly.