Specially designed for applications where small size of the probe and light weight are crucial. The TMS21 can be highly customized due to its versatility. It can monitor the temperature on a very high number of points along a line just by using one process connection. It is composed of several low diameters thermocouples protected by one overall primary tube thermowell. Two different product configurations are available, with or without flexible upper thermowell-hose (for axial centering).
Compare

Thermometer

Measuring Principle Thermocouple
Characteristic / Application metric style
imperial style
easy-to-use
suitable for hazardous areas
compression fitting as process connection
without neck
light chemical processes
Thermowell / protection tube without (not intended to use with thermowell)
Insert / probe mineral insulated (MI), flexible
Outer diameter protection tube / Insert 6,0 mm (0,24'')
3,2 mm (0,126")
8,0 mm (0,31")
9,5 mm (0,37")
6,35 mm (1/4")
Max. immersion length on request up to 13.000,00 mm (511,81'')
Material protection tube/ thermowell 1.4401 (316)
1.4435 (316L)
1.4571 (316Ti)
1.4541 (321)
1.4550 (347)
Alloy 600 (2.4816)
Process connection Compression fitting threaded 1/4"
Compression fitting threaded 1/2"
Compression fitting threaded 3/4"
Compression fitting threaded 1"
Flange as an accessory
Tip shape straight
Operating temperature range Type K:
max. 920 °C
(max. 1.688 °F)
Type J:
max. 440 °C
(max. 824 °F)
Type N:
max. 920 °C
(max. 1.688 °F)
Type E:
max. 510 °C
(max. 950 °F)
Max. process pressure (static) at 20 °C: 90 bar (1305 psi)
Accuracy class 2 acc. to IEC 60584
ASTM E230 and ANSI MC 96.1
Response time t50 = 3 s
t90 = 9 s
Integration head transmitter yes (4 … 20 mA; HART; PROFIBUS PA; FOUNDATION FIELDBUS)
Ex - approvals ATEX Ex ia
IECEx Ex ia
IECEx ATEX Ex ia
NEPSI Ex ia
UKCA Ex ia
EAC Ex ia
UL
CSA
Certification SIL (transmitter only)

iTHERM MultiSens Slim TMS21
Multipoint thermometer
Low-invasive, flexible TC temperature profile solution for petrochemical and chemical applications
Benefits
Large number of measuring points with a small diameter

Low-invasive temperature profile probe

Easy installation and wiring
Application areas
Designed for applications where small probe dimensions and low weight are required. The TMS21 is versatile and can be highly customized. It monitors the temperature at a large number of points along a production line using just one process connection. It consists of several small-diameter thermocouples protected by one monolithic primary tube thermowell. Two different product configurations are available, with or without a flexible upper thermowell (for axial centering).

Spare Parts & Accessories 9

9 spare parts · click to collapse
Order codeDescription
TMT31-F+ Temperature transmitter TMT312-wire temperature transmitter. Single sensor input. Application: RTD/TC. Factory setup w/o additional specification: Pt100, 4-wire, 0...+100oC, presetting failure current low. Consider additional marine certificate requirements on application side.Enquire
TMT71-Temperature transmitter TMT712-wire temperature transmitter. Single universal sensor input. Galvanic isolation 2kV (input/output). Application: RTD, TC, Ohm and mV. Factory setup w/o additional specification:Pt100, 4-wire, 0...+100oC.Enquire
TMT72-Temperature transmitter TMT722-wire temperature transmitter. Single universal sensor input. Galvanic isolation 2kV (input/output). Application: RTD, TC, Ohm and mV. Factory setup w/o additional specification: Pt100, 4-wire, 0...+100oCEnquire
TMT82-Temperature transmitter TMT822-wire temperature transmitter. Dual universal sensor input. Galvanic isolation 2kV (input/output). Application: RTD, TC, Ohm and mV. Presetting failure current high. Consider additional marine certificate requirements on application side. ::Highly reliable due to drift detection and sensor back up. ::Optional also for safety critical applications by means of SIL 2/3 acc. to IEC61508.Enquire
TMT84-Temperature transmitter TMT84Dual sensor input. Advanced diagnostics: sensor monitoring. Galvanic isolation 2kV. Application: RTC, TC, Ohm, mV. Current consumption: 11 mA. Mounting: head form B, DIN43729. Factory setup: CH1: Pt100, 3-wire, oC CH2: inactive Differing configuration optional selectable.Enquire
TMT85-Temperature transmitter TMT85Temperature transmitter with dual sensor input and advanced diagnostics for sensor monitoring. FOUNDATION Fieldbus protocol (ITK 5.0). Galvanic isolation 2 kV (sensor input to the output). Application: RTC, TC, Ohm, mV. Current consumption: 11 mA. Mounting: head form B, DIN43729. UL listed, CSA General Purpose.Enquire
TMT86-Temperature transmitter TMT862-wire Ethernet transmitter. Dual universal sensor input. Galvanic isolation 2kV (input/output). Application: RTD, TC, Ohm and mV. Factory setup w/o additional specification: CH1: Pt100, 4-wire, oC, CH2: inactive.Enquire
71044061equipment package2x screws, 2x springs, 2x spring rings, 1x sealing CDI-connectorDetails
71044062equipment package2x screws, 1x sealing CDI-connectorDetails

Configurator / Comparison

ConfigureEnter a product model to configure
CompareEnter the product models to compare — up to three products

Product comparison

Please enter the product order codes to be compared in the input boxes below; a maximum of three products can be compared

 

Technical documentation

  

 

 

Accessories / Spare parts

 

Source:Endress+Hauser website public information

Measuring principle video

Click to play
All documents for this model
4 documents · click to expand
BA

BA iTHERM TMS21 MultiSens Slim Chinese

Rev. 0525 36 pages
Preview
BA

BA iTHERM TMS21 MultiSens Slim English

Rev. 0525 40 pages
Preview
TI

TI iTHERM MultiSens Slim TMS21 多点温度计 Chinese

Rev. 0525 20 pages
Preview
TI

TI iTHERM MultiSens Slim TMS21 Multipoint Thermometer English

Rev. 0525 24 pages
Preview
Municipal Wastewater Treatment

Municipal Wastewater Treatment · thermocouples — Application Case

Project Background

The project covers the inlet, biological and outlet stages of a municipal plant. The work centres on thermocouples and the core task is high-temperature measurement with thermocouples.

Operating Challenges

The medium and duty are characterised by high solids and corrosive fractions, with large diurnal flow swings, and effluent parameters drift and probes foul with sludge and biofilm. So thermocouples cannot be specified generically — it calls for choosing the type by temperature limit, atmosphere and response speed.

Solution

The Ainstru engineering team worked through the temperature range: temperature solution matched to measuring point and response needs. The configuration involves choosing the type by temperature limit, atmosphere and response speed, with these requirements in view: stable compliance with Grade 1A discharge limits and online data reporting.

Results

Since start-up the system has run steadily; the practical result is strong high-temperature capability, measuring furnace temperatures directly.

Food & Beverage

Food & Beverage · thermocouples — Application Case

Project Overview

The site is dosing, pasteurising, filling and CIP stages. The customer wanted thermocouples properly configured on the existing plant, with the aim of high-temperature measurement with thermocouples.

Technical Challenges

What actually causes trouble is syrups, dairy and beverages that scale easily, under strict hygienic requirements, and frequent cleaning demands instruments that withstand hot CIP/SIP caustic cycles. All of this means the thermocouples configuration has to involve choosing the type by temperature limit, atmosphere and response speed.

Configuration

Supply and installation were organised through the temperature range: temperature solution matched to measuring point and response needs. On site this meant choosing the type by temperature limit, atmosphere and response speed, checked line by line against: food-safety and hygienic design per 3-A / EHEDG.

Performance

After commissioning the outcome is strong high-temperature capability, measuring furnace temperatures directly, and the readings are now used for process tuning.

Chemical & Pharmaceutical

Chemical & Pharmaceutical · thermocouples — Application Case

Site Conditions

This is a Chemical & Pharmaceutical customer whose plant is at reactors, metering vessels and finished-product tanks. The main task was high-temperature measurement with thermocouples.

The Problem

The difficulty lies in highly corrosive media with solvents and crystallisation, partly in explosive atmospheres; at the same time corrosion plus Ex protection shortens instrument life and makes downtime costly. Specification therefore means choosing the type by temperature limit, atmosphere and response speed.

What We Did

We took a temperature range approach — temperature solution matched to measuring point and response needs. Delivery was built around choosing the type by temperature limit, atmosphere and response speed, with point-by-point checks on: Ex certification and GMP traceability of records.

Operating Outcome

In service the system performs as intended — strong high-temperature capability, measuring furnace temperatures directly, with routine maintenance falling noticeably.

Power & Energy

Power & Energy · thermocouples — Application Case

Application Context

boiler feedwater, turbine condensate and FGD/DeNOx systems is a typical Power & Energy duty. The project started from thermocouples, focusing on high-temperature measurement with thermocouples.

Process Constraints

drift under high temperature and pressure, with very costly unplanned outages, and high temperature and pressure with both steam and saline water only amplify it. The thermocouples specification must therefore cover choosing the type by temperature limit, atmosphere and response speed.

Delivery Approach

Delivery was handled as the temperature range — temperature solution matched to measuring point and response needs. Execution centred on choosing the type by temperature limit, atmosphere and response speed, together with compliance with power-industry codes and unit availability targets.

Field Results

Operation shows the benefit clearly — strong high-temperature capability, measuring furnace temperatures directly, with confidence in this measuring point improving markedly.