Instrumentation · Engineering · Package · PLC
0755-82221901 sales@ainstru.com

TT151 temperature sleeve

TT151 temperature sleeve
iTHERM ModuLine TT151
The overall drilling rod protection sleeve ensures safe and reliable temperature measurement under harsh working conditions, with a maximum capacity of 500 bar
Compare

Thermowell

Measuring Principle Bar stock Thermowell
Characteristic / Application metric style
compliant according to ASME, DIN or NAMUR standard
universal use
Head connection internal thread:
M14x1,5
M18x1,5
M20x1,5
M27x2
1/2" NPT
1/2" NPSM
1/2"NPSC
G1/2"
G3/4"
M24x1,5 sliding
Maximum standard immersion length 1500 mm
Process connection To be
threaded
weld in
with flange according to ASME, EN or ISO
Thermowell root diameter 9…50 mm
Medium contact material Wide selection of materials including:
316
316L
316Ti
347
310
Alloy600
AlloyC276
10CrMo9-10
13CrMo4-5
16Mo3
A105
C22.8
Duplex
Titan Gr.2
316+316L dual rated
P355NH
Wetted part finishing (Ra) < 0.8 μm (31.50 μin)
< 1.6 μm (63.00 μin)
DIN Standard
Tip shape Straight
Tappered
Stepped
partly tappered
Temperature range -200…1100 °C (-328...2.012 °F)
Depending on Configuration
Max. process pressure (static) 500 bar (7252 psi)
Depending on Configuration
Max. process pressure at 400 °C depends on process connection and material

The TT151 thermowell is designed in accordance with DIN 43772, ASME B40.9 and NAMUR NE 170 standards and also supports custom design on request. The robust thermowell is installed in process pipes or tanks and effectively protects the built-in temperature sensor against harsh process conditions, enabling safe, high-precision temperature measurement. The thermowell is made from solid drilled bar stock, with a tip diameter between 9...50 mm. Tip types include straight, reduced and stepped. The following process connections are supported: standard flange, thread, socket weld.

Advantages
TT151 standard industrial thermowell made from solid drilled bar stock
Modular design complying with DIN 43772, ASME B40.9 and NAMUR NE 170 standards, versatile and flexibly customizable
Flexible selection of the extension length, insertion depth and total length according to the actual operating conditions
Various sizes, materials and process connections available for flexible selection

Field of application
Protects the temperature sensor against physical and chemical deformation
Reliable operation under demanding conditions
Maximum pressure rating: 500 bar (7252 psi)
Installed in pipes, vessels or tanks
More convenient maintenance and recalibration of the measuring point (sensor replacement without interrupting the production process)

 

Configurator / Comparison

ConfigureEnter a product model to configure
CompareEnter the product models to compare — up to three products

   

   

 

 

Accessories/Spare parts

 

Measuring principle video

Click to play
All documents for this model
4 documents · click to expand
BA

BA 温度计保护套管 Chinese

Rev. 0120 20 pages
Preview
BA

Thermowells for thermometers English

Rev. 0120 20 pages
Preview
TI

TI iTHERM ModuLine TT151 Chinese

Rev. 0525 32 pages
Preview
TI

TI iTHERM ModuLine TT151 English

Rev. 0525 36 pages
Preview
Municipal Wastewater Treatment

Municipal Wastewater Treatment · temperature casing — Application Case

Application Context

the inlet, biological and outlet stages of a municipal plant is a typical Municipal Wastewater Treatment duty. The project started from temperature casing, focusing on providing pressure-tight isolation and protection for temperature elements.

Process Constraints

effluent parameters drift and probes foul with sludge and biofilm, and high solids and corrosive fractions, with large diurnal flow swings only amplify it. The temperature casing specification must therefore cover sizing strength and vibration frequency against flow velocity, pressure and corrosivity.

Delivery Approach

Delivery was handled as the temperature range — temperature solution matched to measuring point and response needs. Execution centred on sizing strength and vibration frequency against flow velocity, pressure and corrosivity, together with stable compliance with Grade 1A discharge limits and online data reporting.

Field Results

Operation shows the benefit clearly — longer well life, avoiding breakage that disrupts the process, with confidence in this measuring point improving markedly.

Food & Beverage

Food & Beverage · temperature casing — Application Case

Customer Profile

The typical setting in Food & Beverage is dosing, pasteurising, filling and CIP stages. The measuring point is temperature casing; the focus is providing pressure-tight isolation and protection for temperature elements.

Key Difficulties

Conditions are syrups, dairy and beverages that scale easily, under strict hygienic requirements and, on top of that, frequent cleaning demands instruments that withstand hot CIP/SIP caustic cycles, which a standard configuration cannot handle for long. The design therefore starts with sizing strength and vibration frequency against flow velocity, pressure and corrosivity.

Implementation

The scope ran through the temperature range: temperature solution matched to measuring point and response needs. Technically it hinges on sizing strength and vibration frequency against flow velocity, pressure and corrosivity, and on these requirements: food-safety and hygienic design per 3-A / EHEDG.

Customer Benefit

In practice this means longer well life, avoiding breakage that disrupts the process, which cut the workload on the site maintenance team.

Chemical & Pharmaceutical

Chemical & Pharmaceutical · temperature casing — Application Case

Project Background

The project covers reactors, metering vessels and finished-product tanks. The work centres on temperature casing and the core task is providing pressure-tight isolation and protection for temperature elements.

Operating Challenges

The medium and duty are characterised by highly corrosive media with solvents and crystallisation, partly in explosive atmospheres, and corrosion plus Ex protection shortens instrument life and makes downtime costly. So temperature casing cannot be specified generically — it calls for sizing strength and vibration frequency against flow velocity, pressure and corrosivity.

Solution

The Ainstru engineering team worked through the temperature range: temperature solution matched to measuring point and response needs. The configuration involves sizing strength and vibration frequency against flow velocity, pressure and corrosivity, with these requirements in view: Ex certification and GMP traceability of records.

Results

Since start-up the system has run steadily; the practical result is longer well life, avoiding breakage that disrupts the process.

Power & Energy

Power & Energy · temperature casing — Application Case

Project Overview

The site is boiler feedwater, turbine condensate and FGD/DeNOx systems. The customer wanted temperature casing properly configured on the existing plant, with the aim of providing pressure-tight isolation and protection for temperature elements.

Technical Challenges

What actually causes trouble is high temperature and pressure with both steam and saline water, and drift under high temperature and pressure, with very costly unplanned outages. All of this means the temperature casing configuration has to involve sizing strength and vibration frequency against flow velocity, pressure and corrosivity.

Configuration

Supply and installation were organised through the temperature range: temperature solution matched to measuring point and response needs. On site this meant sizing strength and vibration frequency against flow velocity, pressure and corrosivity, checked line by line against: compliance with power-industry codes and unit availability targets.

Performance

After commissioning the outcome is longer well life, avoiding breakage that disrupts the process, and the readings are now used for process tuning.