Technical Data
CompareThermowell
| Measuring Principle | Fabricated Thermowell |
| Characteristic / Application | metric style hygienic/aseptic design (3-A®, EHEDG, ASME BPE, FDA) hygienic process connections iTHERM QuickNeck for easy and cost saving recalibration |
| Head connection | iTHERM QuickNeck male thread: M24x1,5 G3/8" |
| Maximum standard immersion length | 4.000 mm (157,48") |
| Max. immersion length on request | Not defined |
| Process connection | compression fitting weld in adaptor clamp connections acc. to ISO2852 screwed pipe joint acc. to DIN 11851 aseptic screwed pipe joint acc. to DIN 11864-1 metallic sealing system thread acc. to ISO 228 for liquiphant adaptor APV Inline Varivent Ingold SMS 1147 Neumo Biocontrol Tee and elbow thermowells DIN11865 |
| Thermowell root diameter | 6,0 mm (0,24") 9,0 mm (0,35") 12,7 mm (0,5") |
| Medium contact material | 1.4435 delta-ferrit < 1% 316L |
| Wetted part finishing (Ra) | < 0,76 μm (29,92 μin) < 0,38 μm (14,96 μin) < 0,38 μm (14,96 μin) electropolished |
| Tip shape | straight reduced tappered |
| Temperature range | -200...650 °C (-328...1.202 °F) |
| Max. process pressure (static) | 40 bar (580 psi) |
| Max. process pressure at 400 °C | depends on process connection |
Ideally suited for hygienic or sterile pipes, vessels or tanks with very small immersion depths. It meets the requirement for enhanced protection of the thermometer against physical and chemical influences and is the ideal choice for all measuring points where the working element is replaced in a closed process and regular recalibration is required.
Advantages
iTHERM QuickNeck - simple, tool-free recalibration of the working element, saving time and costs
More than 50 hygienic process connections
Metric and imperial versions available, suitable for worldwide use
International certifications: complies with 3-A®, EHEDG, ASME BPE,
FDA, TSE hygiene standards, certificates of suitability
Option: 1.4435 material, delta ferrite content < 1%
Shortened tip and thin thermowell wall for faster response time
Advanced tee and elbow elements without welds and dead spaces, featuring industry-leading hygienic design
Field of application
Designed specifically for hygienic and aseptic applications in the food & beverage and life sciences industries
Maximum process pressure (static): 40 bar (580 psi)
Meets the requirement for enhanced protection of the thermometer against physical and chemical influences
Suitable for immersion in pipes, vessels or tanks
The ideal choice for all measuring points where the working element is replaced in a closed process and regular recalibration is required
Spare Parts & Accessories 24
24 spare parts · click to collapse
| Order code | Description | |
|---|---|---|
| 71531585 | Adapter for Ingold connection, 3.1Material certificate | Details |
| 71531588 | Adapter for Ingold connection | Details |
| 71667250 | Spare parts kit, gasket, Ingold connectionO-ring 18.64x3.53 FKM/FPM FDA black. Packing unit: 5 pieces. | Details |
| 52018765 | weld socketFlush mount process connection FTL20 "1", FTL20H "GDJ", FMI51, FTI51 "GQJ" Material: 316L, EHEDG compliant Seal: Silicone O-ring Inspection cert. EN10204-3.1 material (316L wetted parts) | Details |
| 52021717 | O-ringfor weld-in adapter G3/4 D=50 316L Liquiphant T FTL20H | Details |
| 52028295 | weld socketFlush mount process connection FTL20 "1", FTL20H "GDJ" w/o flange Material: 316L, EHEDG compliant Seal: Silicone O-ring Inspection cert. EN10204-3.1 material (316L wetted parts) | Details |
| 52001052 | weld socketFlush mount process connection FTL50/FTL50H "GQ2" Material: 316L Seal: Silicone O-ring | Details |
| 52011897 | weld socketFlush mount process connection. Material: 316L. Inspection cert. EN10204-3.1 material. Seal: silicone O-ring. FDA, 3-A compliant. additional EPDM O-ring. FDA, EHEDG, 3-A, USP Class VI compliant. Usage: FTL41, FTL43, FTL50, FTL50H, FTL51B, FTL63, FTL80, QMW43, TMR35. | Details |
| 52014473 | O-ringfor weld-in adapter G3/4 Liquiphant M "GQ2" | Details |
| 52001051 | Process connection | Weld-in G1, d=60, 316L齐平安装式过程连接 FTL260 "0", FTL20 "7", FTL20H "GEJ", FTL330H/FTL330L "G", FTL50/FTL51, FTL50H/FTL51H "GW2", FMI51/FMI52, FTI51/FTI52 "GWJ", PMP135 "N", PTP35 "BB" 材质: 316L 密封: 硅橡胶 O-ring | Details |
| 52011896 | Welding socket, G1, d=60, 3.1 material certificateFlush mount process connection FTL260 "0", FTL20H "GEJ", FTL50/FTL51, FTL50H/FTL51H "GW2", FMI51/FMI52, FTI51/FTI52 "GWJ", PMP135 "N", PTP35 "BB" Material: 316L Seal: Silicone O-ring Inspection cert. EN10204-3.1 material (316L wetted parts) | Details |
| 52014472 | O-ringfor weld-in adapter G1 (52001051) Liquiphant M "GW2" Liquiphant T "7", Liquicap M "GWJ", Cerabar T PMP135 "N", Ceraphant T PTP35 "BB" for weld-in andapter G1, 316L 3.1 (52011896) Liquiphant M "GW2", Cerabar T PMP135 "N", Ceraphant T PTP35 "BB" for sliding sleeve Soliphant T | Details |
| 71093129 | weld socketFlush mount process connection. Material: 316L. Inspection cert. EN10204-3.1 material Seal: silicone O-ring FDA, 3-A compliant. Additional EPDM O-ring. FDA, EHEDG, 3-A, USP Class VI compliant. Usage: FMI51, FMI52, FTI51, FTI52, FTL31, FTL20H, FTL33, FTL41, FTL43, FTL50, FTL50H, FTL51, FTL51B, FTL51H, FTL63, FTL80, FTL81, FTL260, PMP135, PTP35, PTP33B, PMP23, PMP43, PMP51, FTW23, FTW33, QMW43. | Details |
| 52001221 | weld socketFlush mount process connection FTL260 "0", FTL20 "7", FTL20H "GEJ", FTL330H/FTL330L "G", FTL50/FTL51, FTL50H/FTL51H "GW2" Liquiphant is adjustable Material: 316L Seal: Silicone O-ring | Details |
| 52011898 | weld socketFlush mount process connection FTL260 "0", FTL20H "GEJ", FTL50/FTL51, FTL50H/FTL51H "GW2" Liquiphant is adjustable Material: 316L Seal: Silicone O-ring Inspection cert. EN10204-3.1 material (316L wetted parts) | Details |
| 52014424 | Sealing gasketfor weld-in adapter G1, adjustable, 316L (52001221) Liquiphant M "GW2" for weld-in adapter G1, adjustable, 316L (52011898) Liquiphant M "GW2" for weld-in adapter G1, adjustable Liquiphant FTL330H/FTL330L, Liquiphant T FTL20H "UPJ | Details |
| 71405560 | Weld-in adapter M12x1.5 1.4435/316L | Details |
| 71424800 | 1/2" G-thread basefor connection with G1/2" female thread. Material 316L/1.4435. 2x leakage bore. | Details |
| 60022519 | screw plug | Details |
| 71535692 | Plug screw fitting 316L M12x1.5 | Details |
Configurator / Comparison
Measuring principle video
Click to playManuals & Documents 7
All documents for this model7 documents · click to expand
Case Studies
Municipal Wastewater Treatment · temperature casing — Application Case
Application Context
the inlet, biological and outlet stages of a municipal plant is a typical Municipal Wastewater Treatment duty. The project started from temperature casing, focusing on providing pressure-tight isolation and protection for temperature elements.
Process Constraints
effluent parameters drift and probes foul with sludge and biofilm, and high solids and corrosive fractions, with large diurnal flow swings only amplify it. The temperature casing specification must therefore cover sizing strength and vibration frequency against flow velocity, pressure and corrosivity.
Delivery Approach
Delivery was handled as the temperature range — temperature solution matched to measuring point and response needs. Execution centred on sizing strength and vibration frequency against flow velocity, pressure and corrosivity, together with stable compliance with Grade 1A discharge limits and online data reporting.
Field Results
Operation shows the benefit clearly — longer well life, avoiding breakage that disrupts the process, with confidence in this measuring point improving markedly.
Food & Beverage · temperature casing — Application Case
Customer Profile
The typical setting in Food & Beverage is dosing, pasteurising, filling and CIP stages. The measuring point is temperature casing; the focus is providing pressure-tight isolation and protection for temperature elements.
Key Difficulties
Conditions are syrups, dairy and beverages that scale easily, under strict hygienic requirements and, on top of that, frequent cleaning demands instruments that withstand hot CIP/SIP caustic cycles, which a standard configuration cannot handle for long. The design therefore starts with sizing strength and vibration frequency against flow velocity, pressure and corrosivity.
Implementation
The scope ran through the temperature range: temperature solution matched to measuring point and response needs. Technically it hinges on sizing strength and vibration frequency against flow velocity, pressure and corrosivity, and on these requirements: food-safety and hygienic design per 3-A / EHEDG.
Customer Benefit
In practice this means longer well life, avoiding breakage that disrupts the process, which cut the workload on the site maintenance team.
Chemical & Pharmaceutical · temperature casing — Application Case
Project Background
The project covers reactors, metering vessels and finished-product tanks. The work centres on temperature casing and the core task is providing pressure-tight isolation and protection for temperature elements.
Operating Challenges
The medium and duty are characterised by highly corrosive media with solvents and crystallisation, partly in explosive atmospheres, and corrosion plus Ex protection shortens instrument life and makes downtime costly. So temperature casing cannot be specified generically — it calls for sizing strength and vibration frequency against flow velocity, pressure and corrosivity.
Solution
The Ainstru engineering team worked through the temperature range: temperature solution matched to measuring point and response needs. The configuration involves sizing strength and vibration frequency against flow velocity, pressure and corrosivity, with these requirements in view: Ex certification and GMP traceability of records.
Results
Since start-up the system has run steadily; the practical result is longer well life, avoiding breakage that disrupts the process.
Power & Energy · temperature casing — Application Case
Project Overview
The site is boiler feedwater, turbine condensate and FGD/DeNOx systems. The customer wanted temperature casing properly configured on the existing plant, with the aim of providing pressure-tight isolation and protection for temperature elements.
Technical Challenges
What actually causes trouble is high temperature and pressure with both steam and saline water, and drift under high temperature and pressure, with very costly unplanned outages. All of this means the temperature casing configuration has to involve sizing strength and vibration frequency against flow velocity, pressure and corrosivity.
Configuration
Supply and installation were organised through the temperature range: temperature solution matched to measuring point and response needs. On site this meant sizing strength and vibration frequency against flow velocity, pressure and corrosivity, checked line by line against: compliance with power-industry codes and unit availability targets.
Performance
After commissioning the outcome is longer well life, avoiding breakage that disrupts the process, and the readings are now used for process tuning.