Instrumentation · Engineering · Package · PLC
0755-82221901 sales@ainstru.com

TT152 iTHERM ModuLine

TT152 iTHERM ModuLine
iTHERM ModuLine TT152
TT512 thermowell (imperial instrument), suitable for various demanding process applications
Compare

Thermowell

Measuring Principle Bar stock Thermowell
Characteristic / Application imperial style
compliant according to ASME standard
Head connection internal thread:
1/2" NPT
Maximum standard immersion length 84 in
Process connection To be
threaded
weld in
with flange according to ASME
Thermowell root diameter 5/8…1-1/2 in
Medium contact material Wide selection of materials including:
316/316L
304/304L
Alloy600
AlloyC276
A182 F22
A182 F11
A182 F91
A105
Duplex
PTFE coated
Tantalum sleeve
Wetted part finishing (Ra) < 0.8 μm (31.50 μin)
< 1.6 μm (63.00 μin)
Tip shape Straight
Tappered
Stepped
partly tappered
Temperature range -200…1100 °C (-328...2.012 °F)
Depending on Configuration
Max. process pressure (static) 500 bar (7252 psi)
Depending on Configuration
Max. process pressure at 400 °C depends on process connection and material

TT512 Thermowell (imperial instrument), suitable for various demanding applications

Advantages

Easy maintenance and recalibration of the thermometer (sensor replacement without interrupting the process)

iTHERM TwistWell with helical design: reduces the influence of vortex vibration on measurement in high-flow applications

Flexible customization of thermowell shaft length, immersion depth and total length according to actual conditions

Available in a variety of sizes, materials and process connection types

Certified to multiple international standards: e.g. pressure test

Application

The iTHERM ModuLine TT152 thermowell is designed in accordance with ASME B40.9, or customized to user requirements. Machined or gun-drilled from solid bar stock, it protects thermometers used in demanding conditions.

  • Protects the temperature sensor from physical and chemical deformation
  • Rugged and durable, suitable for demanding conditions
  • Maximum pressure resistance: 500 bar (7,252 psi)
  • Mounted on pipes, vessels or tanks

Configurator / Comparison

ConfigureEnter a product model to configure
CompareEnter the product models to compare — up to three products

Measuring principle video

Click to play
All documents for this model
2 documents · click to expand
TI

TI iTHERM ModuLine TT152 Chinese

Rev. 0124 20 pages
Preview
TI

TI iTHERM ModuLine TT152 Barstock thermowell English

Rev. 0326 24 pages
Preview
Municipal Wastewater Treatment

Municipal Wastewater Treatment · temperature casing — Application Case

Application Context

the inlet, biological and outlet stages of a municipal plant is a typical Municipal Wastewater Treatment duty. The project started from temperature casing, focusing on providing pressure-tight isolation and protection for temperature elements.

Process Constraints

effluent parameters drift and probes foul with sludge and biofilm, and high solids and corrosive fractions, with large diurnal flow swings only amplify it. The temperature casing specification must therefore cover sizing strength and vibration frequency against flow velocity, pressure and corrosivity.

Delivery Approach

Delivery was handled as the temperature range — temperature solution matched to measuring point and response needs. Execution centred on sizing strength and vibration frequency against flow velocity, pressure and corrosivity, together with stable compliance with Grade 1A discharge limits and online data reporting.

Field Results

Operation shows the benefit clearly — longer well life, avoiding breakage that disrupts the process, with confidence in this measuring point improving markedly.

Food & Beverage

Food & Beverage · temperature casing — Application Case

Customer Profile

The typical setting in Food & Beverage is dosing, pasteurising, filling and CIP stages. The measuring point is temperature casing; the focus is providing pressure-tight isolation and protection for temperature elements.

Key Difficulties

Conditions are syrups, dairy and beverages that scale easily, under strict hygienic requirements and, on top of that, frequent cleaning demands instruments that withstand hot CIP/SIP caustic cycles, which a standard configuration cannot handle for long. The design therefore starts with sizing strength and vibration frequency against flow velocity, pressure and corrosivity.

Implementation

The scope ran through the temperature range: temperature solution matched to measuring point and response needs. Technically it hinges on sizing strength and vibration frequency against flow velocity, pressure and corrosivity, and on these requirements: food-safety and hygienic design per 3-A / EHEDG.

Customer Benefit

In practice this means longer well life, avoiding breakage that disrupts the process, which cut the workload on the site maintenance team.

Chemical & Pharmaceutical

Chemical & Pharmaceutical · temperature casing — Application Case

Project Background

The project covers reactors, metering vessels and finished-product tanks. The work centres on temperature casing and the core task is providing pressure-tight isolation and protection for temperature elements.

Operating Challenges

The medium and duty are characterised by highly corrosive media with solvents and crystallisation, partly in explosive atmospheres, and corrosion plus Ex protection shortens instrument life and makes downtime costly. So temperature casing cannot be specified generically — it calls for sizing strength and vibration frequency against flow velocity, pressure and corrosivity.

Solution

The Ainstru engineering team worked through the temperature range: temperature solution matched to measuring point and response needs. The configuration involves sizing strength and vibration frequency against flow velocity, pressure and corrosivity, with these requirements in view: Ex certification and GMP traceability of records.

Results

Since start-up the system has run steadily; the practical result is longer well life, avoiding breakage that disrupts the process.

Power & Energy

Power & Energy · temperature casing — Application Case

Project Overview

The site is boiler feedwater, turbine condensate and FGD/DeNOx systems. The customer wanted temperature casing properly configured on the existing plant, with the aim of providing pressure-tight isolation and protection for temperature elements.

Technical Challenges

What actually causes trouble is high temperature and pressure with both steam and saline water, and drift under high temperature and pressure, with very costly unplanned outages. All of this means the temperature casing configuration has to involve sizing strength and vibration frequency against flow velocity, pressure and corrosivity.

Configuration

Supply and installation were organised through the temperature range: temperature solution matched to measuring point and response needs. On site this meant sizing strength and vibration frequency against flow velocity, pressure and corrosivity, checked line by line against: compliance with power-industry codes and unit availability targets.

Performance

After commissioning the outcome is longer well life, avoiding breakage that disrupts the process, and the readings are now used for process tuning.