DRB200 COD Digestion Reactor (COD Rapid Digestion Reactor) is a digestion device developed by HACH, capable of total phosphorus, total nitrogen, TOC, and COD digestion. The digestion time and digestion temperature of this COD digestion reactor can be selected within the ranges of 0-480 minutes and 37-165°C respectively. To meet broader application needs, the DRB200 COD Digestion Reactor is available in two configurations: single heating block or dual independent heating blocks. The dual heating block supports simultaneous digestion of water samples under different temperature and duration settings. The heating blocks offer 3 size specifications, suitable for TNTplus pre-dosed reagents with barcode (13mm), standard TNT pre-dosed tubes (16mm), and metal digestion pretreatment pre-dosed tubes (20mm) respectively.
  • - Principle of operation:

  • The DRB200 COD Digester (COD rapid digester) uses a heating module and preset heating programs to heat and digest water samples such as COD, TOC, total phosphorus, and total nitrogen for different prepared reagents.

Technical specifications

  • Specifications    Details

  • Dimensions    25×14.5×31 cm (9.8×5.7×12.2 in)

  • Weight    Single heating block: 2 kg (4.4 lb)

  • Dual heating block: 2.8 kg (6.17 lb)

  • Power requirements    100-240V, +5%/-15%, 50/60Hz, Protection class I

  • Power input    Single heating block: 115V: 300VA: 230V: 450VA

  • Dual heating block: 115V: 600VA: 230V: 900VA

  • Storage temperature    -40 to +60℃ (-40 to +140°F)

  • Operating temperature    10 to 45℃ (50 to 113°F)

  • Operating humidity    90% (non-condensing)

  • Instrument range    Temperature: 37 to 165℃ (98.6 to 329°F)

  • Timer: 0 to 480 minutes approx.

  • Temperature stability    ±2℃ (±3.5°F)

  • Heating rate    From 20 to 150℃ (68 to 302°F) takes approx. 10 minutes

  • Certifications    CE, GS, and cTUVus

  • - Application industries:

  • The DRB200 COD Digester (COD rapid digester) can be used in industrial, municipal, environmental protection, university research, and other fields for heating and digestion of water samples such as COD, TOC, total phosphorus, and total nitrogen.

Instrument features:

  • The COD rapid digester offers selectable digestion temperature and time: adjustable temperature range 37°C -165°C, adjustable time range 1-480 minutes approx.

  • The DRB200 COD Digester features a fully insulated module design, allowing separate setting of digestion temperature and time, and simultaneous digestion reactions in two independently controlled heating modules.

  • The DRB200 COD Digester is equipped with multiple heating hole diameters, suitable for different types of prepared reagents, for digestion of water samples such as COD, TOC, total phosphorus, and total nitrogen.

  • The DRB200 COD Digester has built-in digestion programs that users can select with one touch, eliminating the complexity and potential errors of manual settings.

  • The COD rapid digester is equipped with a digital timer that can automatically cut off and alarm, providing high reliability.

  • The DRB200 Digester features an isolated locking design, equipped with a transparent protective cover and anti-overheating safety device.

Accessory information

  • 28958-05    Converts 16mm holes to 13mm holes for digesting TNTplus prepared reagents

  • HHA155    Converts 20mm holes to 16mm holes

Ordering guide
Order No. Number of heating blocks Number of 13mm holes Number of 16mm holes Number of 20mm holes
LTV082.80.30001 1 / 9 2
LTV082.80.40001 1 / 15 /
LTV082.80.42001 2 / 21 4
LTV082.80.44001 2 / 30 /
DRB200-05 1 9 / 2
DRB200-06 2 21 / 4
DRB200-07 2 30 / /
DRB200-08 2 12 / 8
Municipal Wastewater Treatment

Municipal Wastewater Treatment · Hach-lab — Application Case

Project Overview

The site is the inlet, biological and outlet stages of a municipal plant. The customer wanted Hach-lab properly configured on the existing plant, with the aim of laboratory colorimetric and titrimetric water analysis.

Technical Challenges

What actually causes trouble is high solids and corrosive fractions, with large diurnal flow swings, and effluent parameters drift and probes foul with sludge and biofilm. All of this means the Hach-lab configuration has to involve selected by method standard, sample throughput and reagent kit.

Configuration

Supply and installation were organised through the laboratory line: configuring around lab method standards and sample throughput. On site this meant selected by method standard, sample throughput and reagent kit, checked line by line against: stable compliance with Grade 1A discharge limits and online data reporting.

Performance

After commissioning the outcome is standardised methods that make data comparable between labs, and the readings are now used for process tuning.

Food & Beverage

Food & Beverage · Hach-lab — Application Case

Site Conditions

This is a Food & Beverage customer whose plant is at dosing, pasteurising, filling and CIP stages. The main task was laboratory colorimetric and titrimetric water analysis.

The Problem

The difficulty lies in syrups, dairy and beverages that scale easily, under strict hygienic requirements; at the same time frequent cleaning demands instruments that withstand hot CIP/SIP caustic cycles. Specification therefore means selected by method standard, sample throughput and reagent kit.

What We Did

We took a laboratory line approach — configuring around lab method standards and sample throughput. Delivery was built around selected by method standard, sample throughput and reagent kit, with point-by-point checks on: food-safety and hygienic design per 3-A / EHEDG.

Operating Outcome

In service the system performs as intended — standardised methods that make data comparable between labs, with routine maintenance falling noticeably.

Chemical & Pharmaceutical

Chemical & Pharmaceutical · Hach-lab — Application Case

Application Context

reactors, metering vessels and finished-product tanks is a typical Chemical & Pharmaceutical duty. The project started from Hach-lab, focusing on laboratory colorimetric and titrimetric water analysis.

Process Constraints

corrosion plus Ex protection shortens instrument life and makes downtime costly, and highly corrosive media with solvents and crystallisation, partly in explosive atmospheres only amplify it. The Hach-lab specification must therefore cover selected by method standard, sample throughput and reagent kit.

Delivery Approach

Delivery was handled as the laboratory line — configuring around lab method standards and sample throughput. Execution centred on selected by method standard, sample throughput and reagent kit, together with Ex certification and GMP traceability of records.

Field Results

Operation shows the benefit clearly — standardised methods that make data comparable between labs, with confidence in this measuring point improving markedly.

Power & Energy

Power & Energy · Hach-lab — Application Case

Customer Profile

The typical setting in Power & Energy is boiler feedwater, turbine condensate and FGD/DeNOx systems. The measuring point is Hach-lab; the focus is laboratory colorimetric and titrimetric water analysis.

Key Difficulties

Conditions are high temperature and pressure with both steam and saline water and, on top of that, drift under high temperature and pressure, with very costly unplanned outages, which a standard configuration cannot handle for long. The design therefore starts with selected by method standard, sample throughput and reagent kit.

Implementation

The scope ran through the laboratory line: configuring around lab method standards and sample throughput. Technically it hinges on selected by method standard, sample throughput and reagent kit, and on these requirements: compliance with power-industry codes and unit availability targets.

Customer Benefit

In practice this means standardised methods that make data comparable between labs, which cut the workload on the site maintenance team.