Main application areas:
Municipal / Beverage / Drinking water / Power / Food / Surface water / Industrial wastewater
Instrument features:
-
The HQ multi-channel electrochemical meter features an IP67 design, making the entire device including the battery compartment waterproof and dustproof.
-
The HQ multi-channel electrochemical meter has built-in standard procedures for calibration and troubleshooting. Through the illustrated screen display, simple and straightforward calibration and troubleshooting operations are achieved, saving time and effort.
-
The HQ multi-channel electrochemical meter has a Chinese operation interface, meeting the needs of Chinese customers, making it more intuitive and easy to operate.
-
The HQ portable multi-parameter water quality meter features classic electrodes designed to meet different application scenarios, ensuring measurement precision and accuracy.
-
Newly added single-parameter DO portable meter and three-channel portable analysis meter.
Technical specifications
-
Model HQ1110 HQ1130 HQ1140 HQ2100 HQ2200 HQ4100 HQ4200 HQ4300
-
pH / ORP DO EC / TDS Multi-parameter* Multi-parameter* Multi-parameter Multi-parameter Multi-parameter
-
Single channel Single channel Single channel Single channel Dual channel Single channel Dual channel Three channel
-
Data storage 5,000 records 10,000 records 100,000 records
-
Display 3.2” monochrome screen 3.2” monochrome screen 3.5” color screen
-
Number of channels 1 1 2 1 2 3
-
Meter weight 519g 519g 541g 530g 550g 570g
-
Warranty 1 year 1 year 3 years
-
Meter dimensions 63mm x 97mm x 220mm
-
Protection class IP67
-
Data storage mode Auto key press read / Interval read / Manual continuous read
-
Data transmission USB connection to computer, direct read
-
Data display Up to three data simultaneously, depending on model
-
Backlight Yes
-
Language Chinese selectable
-
Certifications CE,FCC,ISED, RCM,KC,ETL,US DOE/ NRCan energy saving, RoHS
-
GLP settings Date; Time; Sample ID; Operator ID; Calibration data
-
Power supply 18650 rechargeable lithium battery, Class II, USB charging adapter: 100-240VAC, 50-60HZ
-
Or 2A / 5VDC external power supply device (e.g., power bank)
Ordering guide
-
Product Order No. Product Description
-
LEV015.80.1110A HQ1110 pH/ORP single-parameter meter
-
LEV015.80.1130A HQ1130 DO single-parameter meter
-
LEV015.80.1140A HQ1140 EC/TDS single-parameter meter
-
LEV015.80.2100A HQ2100 portable multi-parameter single-channel (pH/EC/TDS/DO) meter
-
LEV015.80.2200A HQ2200 portable multi-parameter dual-channel (pH/EC/TDS/DO) meter
-
LEV015.80.4100A HQ4100 portable advanced multi-parameter single-channel meter
-
LEV015.80.4200A ee HQ4200 portable advanced multi-parameter dual-channel meter
-
LEV015.80.4300A ee HQ4300 portable advanced multi-parameter three-channel meter
Source: HACH Water Quality website public information
Case Studies
Municipal Wastewater Treatment · Hach-lab — Application Case
Project Overview
The site is the inlet, biological and outlet stages of a municipal plant. The customer wanted Hach-lab properly configured on the existing plant, with the aim of laboratory colorimetric and titrimetric water analysis.
Technical Challenges
What actually causes trouble is high solids and corrosive fractions, with large diurnal flow swings, and effluent parameters drift and probes foul with sludge and biofilm. All of this means the Hach-lab configuration has to involve selected by method standard, sample throughput and reagent kit.
Configuration
Supply and installation were organised through the laboratory line: configuring around lab method standards and sample throughput. On site this meant selected by method standard, sample throughput and reagent kit, checked line by line against: stable compliance with Grade 1A discharge limits and online data reporting.
Performance
After commissioning the outcome is standardised methods that make data comparable between labs, and the readings are now used for process tuning.
Food & Beverage · Hach-lab — Application Case
Site Conditions
This is a Food & Beverage customer whose plant is at dosing, pasteurising, filling and CIP stages. The main task was laboratory colorimetric and titrimetric water analysis.
The Problem
The difficulty lies in syrups, dairy and beverages that scale easily, under strict hygienic requirements; at the same time frequent cleaning demands instruments that withstand hot CIP/SIP caustic cycles. Specification therefore means selected by method standard, sample throughput and reagent kit.
What We Did
We took a laboratory line approach — configuring around lab method standards and sample throughput. Delivery was built around selected by method standard, sample throughput and reagent kit, with point-by-point checks on: food-safety and hygienic design per 3-A / EHEDG.
Operating Outcome
In service the system performs as intended — standardised methods that make data comparable between labs, with routine maintenance falling noticeably.
Chemical & Pharmaceutical · Hach-lab — Application Case
Application Context
reactors, metering vessels and finished-product tanks is a typical Chemical & Pharmaceutical duty. The project started from Hach-lab, focusing on laboratory colorimetric and titrimetric water analysis.
Process Constraints
corrosion plus Ex protection shortens instrument life and makes downtime costly, and highly corrosive media with solvents and crystallisation, partly in explosive atmospheres only amplify it. The Hach-lab specification must therefore cover selected by method standard, sample throughput and reagent kit.
Delivery Approach
Delivery was handled as the laboratory line — configuring around lab method standards and sample throughput. Execution centred on selected by method standard, sample throughput and reagent kit, together with Ex certification and GMP traceability of records.
Field Results
Operation shows the benefit clearly — standardised methods that make data comparable between labs, with confidence in this measuring point improving markedly.
Power & Energy · Hach-lab — Application Case
Customer Profile
The typical setting in Power & Energy is boiler feedwater, turbine condensate and FGD/DeNOx systems. The measuring point is Hach-lab; the focus is laboratory colorimetric and titrimetric water analysis.
Key Difficulties
Conditions are high temperature and pressure with both steam and saline water and, on top of that, drift under high temperature and pressure, with very costly unplanned outages, which a standard configuration cannot handle for long. The design therefore starts with selected by method standard, sample throughput and reagent kit.
Implementation
The scope ran through the laboratory line: configuring around lab method standards and sample throughput. Technically it hinges on selected by method standard, sample throughput and reagent kit, and on these requirements: compliance with power-industry codes and unit availability targets.
Customer Benefit
In practice this means standardised methods that make data comparable between labs, which cut the workload on the site maintenance team.