HI1131P Refillable Single Junction Glass Combination pH Electrode Measuring range: 0 to 13 pH, Sample temperature range: 0 to 100°C (32 to 212°F), Sample pressure ≤0.1 bar; BNC+PIN connector
-
Suitable for routine laboratory, beer and other sample measurements
-
When using a new electrode, first remove the protective cap from the top and inspect the entire electrode. If salt crystals are found on the electrode head and inside the protective cap due to evaporation of the internal electrolyte through the junction, this does not affect normal use of the electrode and indicates that the electrode junction is functioning properly; simply rinse it off with clean water. During transport, air bubbles may form inside the glass bulb at the electrode head. In this case, gently shake the electrode as you would a common mercury thermometer to remove the bubbles. If the glass sensing membrane or junction of the electrode is relatively dry, soak the electrode in HI70300 electrode storage solution for at least 1 hour to keep the dry glass sensing membrane and junction moist; frequent soaking is beneficial for the electrode.
HI1131P features high-temperature (HT) glass, spherical bulb, glass body, single ceramic frit, double junction, refillable with 3.5M KCl.
High-Temperature Glass Formulation
Measuring pH at very high temperatures is harmful to sensitive glass bulbs and shortens their service life. pH electrodes with general-purpose (GP) glass have a resistance of 100 megohms at 25°C, while HT glass has a resistance of approximately 400 megohms at 25°C. Since HI1131P is used at high temperatures, the resistance decreases to approach that of GP glass. HI1131P is suitable for sample measurement ranges of 0 to 100°C.
Spherical Glass Tip
Spherical bulbs are used for general purposes. Other shapes include conical for penetration and flat for surface measurements.
Glass Body
A glass body is ideal for laboratory use. The glass resists many harsh chemicals and is easy to clean. The glass body also allows heat to be transferred quickly to the internal reference electrolyte. The mV generated by the reference cell is temperature-dependent. The faster the electrode reaches equilibrium, the more stable the reference potential.
Single Ceramic Double Junction Reference
HI1131P features a double junction design. pH electrodes are available with either single or double junctions. For a complete explanation of the differences, please refer to the section below. The junction, also called a salt bridge, is an essential component of the circuit. Ion movement must flow through the junction to obtain stable readings. The outer reference has a single ceramic frit. Ceramic is a porous material that fuses easily with the glass body and has a similar coefficient of expansion. The flow rate of a single ceramic junction is 15-20 μL/hour. Other junction types have higher flow rates and are made from different materials.
Refillable
HI1131P is a refillable probe. Since it is a double junction pH electrode, the filling solution is HI7082 3.5M KCl. This solution does not contain any silver, unlike single junction electrodes. The absence of silver prevents any silver precipitate from forming at the junction and clogging it. A clogged junction will cause reading drift and instability.
BNC + Pin Connector
-
HI1131P uses a BNC and pin connector. The BNC connector is universal, as it can be used with any pH meter that has a female BNC probe input. The pin connector is used to enable the CAL Check function on the following benchtop pH meters: HI122, HI123, HI221, HI222, HI223, HI2221, HI2222 and HI2223.
-
Note: Do not use distilled or deionized water to store or soak the electrode, as this will cause the electrode sensor to fail
| Order No. | HI1131P |
| Name | Refillable Combination pH Electrode with BNC + Pin Connector - HI1131P |
| Quote Required | Yes |
| Measuring range | pH |
| Reference cell type | Double, Ag/AgCl |
| Junction type/flow rate | Ceramic, single / 15-20 μL/h |
| Refill electrolyte | 3.5M KCl |
| Body material | Glass |
| Tip/Shape | Spherical (diameter) |
| Matching pin | No |
| Max pressure | 0.1 bar |
| Operating temperature range | 0 to 100°C (32 to 212°F) - HT |
| Temp. sensor | No |
| Cable | Coaxial; 1 m |
| Connector type | BNC + Pin |
| Amplifier | No |
| Recommended use | General purpose, high temperature, general laboratory |
Case Studies
Municipal Wastewater Treatment · Hanna — Stock Configuration Case
Project Overview
The site is the inlet, biological and outlet stages of a municipal plant. The customer wanted Hanna properly configured on the existing plant, with the aim of covering portable and laboratory water testing with Hanna instruments.
Technical Challenges
What actually causes trouble is high solids and corrosive fractions, with large diurnal flow swings, and effluent parameters drift and probes foul with sludge and biofilm. All of this means the Hanna configuration has to involve selected by parameter set, accuracy and field portability.
Configuration
Supply and installation were organised through the stock channel: configuring from stock and delivered quickly. On site this meant selected by parameter set, accuracy and field portability, checked line by line against: stable compliance with Grade 1A discharge limits and online data reporting.
Performance
After commissioning the outcome is results available on site, reducing lab re-checks, and the readings are now used for process tuning.
Food & Beverage · Hanna — Stock Configuration Case
Site Conditions
This is a Food & Beverage customer whose plant is at dosing, pasteurising, filling and CIP stages. The main task was covering portable and laboratory water testing with Hanna instruments.
The Problem
The difficulty lies in syrups, dairy and beverages that scale easily, under strict hygienic requirements; at the same time frequent cleaning demands instruments that withstand hot CIP/SIP caustic cycles. Specification therefore means selected by parameter set, accuracy and field portability.
What We Did
We took a stock channel approach — configuring from stock and delivered quickly. Delivery was built around selected by parameter set, accuracy and field portability, with point-by-point checks on: food-safety and hygienic design per 3-A / EHEDG.
Operating Outcome
In service the system performs as intended — results available on site, reducing lab re-checks, with routine maintenance falling noticeably.
Chemical & Pharmaceutical · Hanna — Stock Configuration Case
Application Context
reactors, metering vessels and finished-product tanks is a typical Chemical & Pharmaceutical duty. The project started from Hanna, focusing on covering portable and laboratory water testing with Hanna instruments.
Process Constraints
corrosion plus Ex protection shortens instrument life and makes downtime costly, and highly corrosive media with solvents and crystallisation, partly in explosive atmospheres only amplify it. The Hanna specification must therefore cover selected by parameter set, accuracy and field portability.
Delivery Approach
Delivery was handled as the stock channel — configuring from stock and delivered quickly. Execution centred on selected by parameter set, accuracy and field portability, together with Ex certification and GMP traceability of records.
Field Results
Operation shows the benefit clearly — results available on site, reducing lab re-checks, with confidence in this measuring point improving markedly.
Power & Energy · Hanna — Stock Configuration Case
Customer Profile
The typical setting in Power & Energy is boiler feedwater, turbine condensate and FGD/DeNOx systems. The measuring point is Hanna; the focus is covering portable and laboratory water testing with Hanna instruments.
Key Difficulties
Conditions are high temperature and pressure with both steam and saline water and, on top of that, drift under high temperature and pressure, with very costly unplanned outages, which a standard configuration cannot handle for long. The design therefore starts with selected by parameter set, accuracy and field portability.
Implementation
The scope ran through the stock channel: configuring from stock and delivered quickly. Technically it hinges on selected by parameter set, accuracy and field portability, and on these requirements: compliance with power-industry codes and unit availability targets.
Customer Benefit
In practice this means results available on site, reducing lab re-checks, which cut the workload on the site maintenance team.
Related Products
HANNA InstrumentsPortable multi-range conductivity meter
HANNA InstrumentsLow range ammonia nitrogen portable photometer
HANNA InstrumentsPortable multi-range turbidimeter
HANNA InstrumentsSaltwater aquarium salinity meter
HANNA InstrumentsPortable honey color analyzer
HANNA InstrumentsPortable free chlorine photometer
HANNA InstrumentsPortable free and total chlorine photometer
HANNA Instruments