Instrumentation · Engineering · Package · PLC
0755-82221901 sales@ainstru.com

HI6321

HI6321

Benchtop conductivity resistivity meter

New generation benchtop conductivity meter

Measurement

  • Measurement of μS/cm, mS/cm (conductivity); Ω·cm, kΩ·cm and MΩ·cm (resistivity); ppm, ppt (TDS); ppt, PSU, % (salinity) as a function of temperature

  • Application-specific profiles allow fast and direct measurement without updating sensor and system settings

  • Activity log during measurement

  • Measurement stability indicator (set using stability criteria)

  • Reading modes: direct and direct/auto-hold

  • Temperature compensation can be set to automatic or manual

  • Audible and/or alarm messages when measurement exceeds predefined limits

  • Galvanic isolation for conductivity measurement


  • The HI6321 is a streamlined benchtop instrument with a large touchscreen display, consisting of the instrument housing and an integrated conductivity measurement module.

  • The HI6321 is compact and easy to operate, and includes Hanna's HI7631233 four-ring conductivity/resistivity/TDS/salinity probe.

  • The HI7631233 is recommended for water applications in a wide range of industrial processes. It provides stable measurement over a wide measuring range and does not require frequent calibration. The integrated temperature sensor measures the process temperature and adjusts the measured conductivity to the reference temperature by applying specialized compensation algorithms:

  • Linear: Applicable when the temperature coefficient of variation is assumed to be the same value for all measured temperatures.

  • Standard: Suitable for high-purity water measurement and documented in ASTM standard D5391-14. This setting should be used for resistivity measurements greater than 1 Mohm.cm.

  • Natural: Suitable for natural groundwater, well water or surface water (or water of similar composition) in accordance with ISO7888.

  • TDS is a calculated value based on the conductivity of the solution (TDS = coefficient x EC25). The TDS coefficient is the conversion factor used to change the EC measurement value to a ppm measurement value.

  • Sal psu: The practical salinity of seawater is related to the ratio of the conductivity of a normal seawater sample at 15°C and 1 atmosphere to that of a potassium chloride solution (KCl) with a mass of 32.4356 g/Kg at the same temperature and pressure. Under these conditions, this ratio is equal to 1 and S = 35. At temperatures from 0 to 35°C, the practical salinity scale is applicable to values from 0 to 42.00 psu.

  • Sal ppt: The measured value expressed in ppt is based on the natural seawater scale from 0.00 to 80.00 g/L, covering a temperature range of 10 to 31°C. It determines salinity based on the conductivity of the sample relative to standard seawater at 15°C and a salinity value of approximately 35 in seawater.

  • Sal%: In this range, 100% salinity corresponds to approximately 10% solids.

  • User Interface

  • 7-inch capacitive touchscreen with multi-touch support

  • Capacitive touchscreen, home and system menu keys

  • User-friendly icons and symbols allow users to easily navigate and interpret instrument functions.

  • Users can choose between five different views:

  • Simple GLP with calibration information

  • Full GLP with electrode status and calibration point details

  • Interactive graph with real-time updates

  • Tabular data including date, time and comments

  • Calibration

  • Standard single-point salinity calibration with 100% salinity standard, reading salinity scale set to %

  • Standard single or multiple conductivity calibration using standards

  • Non-volatile memory retains data and settings

  • Logging

  • Data log collection of at least 1000000 data points (with time and date stamp)

  • Logging types: manual, automatic, auto-hold

  • Sample ID for manual and auto-hold data

  • Connectivity and Services

  • Transfer logged data to USB drive

  • Includes log files of measurement and calibration data (as .csv files)

  • FTP and email for exporting logs via Ethernet and Wi-Fi connection

  • USB Type A for USB flash drive, keyboard and printer

  • USB Type C for USB flash drive and PC connection

  • Instrument Guided Help Section

  • Video-supported demonstrations of main functions


Conductivity EC Measuring range

0.000 to 9.999 μS/cm, 10.00 to 99.99 μS/cm, 100.0 to 999.9 μS/cm, 1.000 to 9.999 mS/cm, 10.00 to 99.99 mS/cm, 100.0 to 1000.0 mS/cm

Resolution

0.001 μS/cm, 0.01 μS/cm, 0.1 μS/cm, 0.001 mS/cm, 0.01 mS/cm, 0.1 mS/cm

Accuracy ±1% of reading (±0.01μS/cm)
Resistivity Measuring range

1.0 to 99.9 Ω•cm; 100 to 999 Ω•cm; 1.00 to 9.99 KΩ•cm; 10.0 to 99.9 KΩ•cm; 100 to 999 KΩ•cm; 1.00 to 9.99 MΩ•cm; 10.0 to 100.0 MΩ•cm

Resolution 0.1 Ω•cm; 1 Ω•cm; 0.01 KΩ•cm; 0.1 KΩ•cm; 1 KΩ•cm; 0.01 MΩ•cm; 0.1 MΩ•cm
Accuracy ±1% of reading (±1 Ω•cm)
TDS Measuring range 0.000 to 9.999 ppm, 10.00 to 99.99 ppm, 100.0 to 999.9 ppm, 1.000 to 9.999 ppt, 10.00 to 99.99 ppt, 100.0 to 400.0 ppt  (conversion factor 1.00 )
Resolution

0.001 ppm, 0.01 ppm, 0.1 ppm, 0.001 ppt, 0.01 ppt, 0.1 pp

Accuracy

±1% of reading (±0.01 ppm)

Salinity Measuring range Practical salinity: 0.00 to 42.00 psu; Seawater salinity: 0.00 to 80.00 ppt; Salinity percentage: 0.0 to 400.0%
Resolution

0.01 (practical salinity, seawater salinity); 0.1% salinity

Accuracy

±1% of reading

Temperature Measuring range

-20.0 to 120.0˚C

Resolution 0.1 °C
Accuracy

±0.2 °C

Conductivity calibration

Calibration points

Auto recommended / user-defined

Standard calibration solutions

84.00μS/cm,1.413mS/cm,5.000mS/cm,12.88mS/cm,80.00mS/cm,111.8mS/cm

Reminder

Off function

Daily: 0 minutes to 23 hours 59 minutes.

Periodic: 1 minute to 500 days, 23 hours 59 minutes

Resistivity calibration

 

Via conductivity calibration

Salinity calibration

 

1 calibration point (percentage)

Temperature compensation

 

Automatic or manual

View

Type

Direct/auto-hold

  Stability

Accurate; Medium; Fast

 

Sampling rate

1000 ms

Conductivity view

Primary

Measurement (EC, resistivity, TDS, salinity, temperature) stability status

Simple GLP

Basic view information

Last calibration data, electrode offset

Full GLP

Simple GLP information and detailed calibration points

Table

Measurement values displayed in a table at one-second intervals

Graph (plot)

pH (or mV) and temperature versus time graph can be panned or zoomed (zoom technology)

Logging

Type

Automatic, manual logging, auto-hold

Number of records

Maximum 50000 per file

Minimum 1000000 data points stored per user

Auto interval 1, 2, 5, 10, 30 seconds
   

1, 2, 5, 10, 15, 30, 60, 120, 150, 180 minutes

 

Sample ID

Increment mode

 

Export options

.csv file format

Users

 

Up to 9 users and administrator. Accounts (default)

Connectivity

USB-A

2 ports for keyboard input or USB-A drive

 

USB-C

1 port for PC connection and USB Type-C drive

 

Wi-Fi & Ethernet

FTP

Web server log transfer and download

Email

 

RS232

Connect peripherals

Power supply

 

DC adapter 100-240AC, 24 VDC 2.5A

Operating environment

 

0 - 50.0 °C

Dimensions/Weight

 

205 x 160 x 77mm / approx. 1.2kg

Ordering information

 

HI6321 meter, conductivity electrode HI7631233; electrode holder HI764060, capillary pipette; 24VDC power adapter; USB-C to USB-A cable; quick start guide with quality certificate

Municipal Wastewater Treatment

Municipal Wastewater Treatment · Hanna — Stock Configuration Case

Project Overview

The site is the inlet, biological and outlet stages of a municipal plant. The customer wanted Hanna properly configured on the existing plant, with the aim of covering portable and laboratory water testing with Hanna instruments.

Technical Challenges

What actually causes trouble is high solids and corrosive fractions, with large diurnal flow swings, and effluent parameters drift and probes foul with sludge and biofilm. All of this means the Hanna configuration has to involve selected by parameter set, accuracy and field portability.

Configuration

Supply and installation were organised through the stock channel: configuring from stock and delivered quickly. On site this meant selected by parameter set, accuracy and field portability, checked line by line against: stable compliance with Grade 1A discharge limits and online data reporting.

Performance

After commissioning the outcome is results available on site, reducing lab re-checks, and the readings are now used for process tuning.

Food & Beverage

Food & Beverage · Hanna — Stock Configuration Case

Site Conditions

This is a Food & Beverage customer whose plant is at dosing, pasteurising, filling and CIP stages. The main task was covering portable and laboratory water testing with Hanna instruments.

The Problem

The difficulty lies in syrups, dairy and beverages that scale easily, under strict hygienic requirements; at the same time frequent cleaning demands instruments that withstand hot CIP/SIP caustic cycles. Specification therefore means selected by parameter set, accuracy and field portability.

What We Did

We took a stock channel approach — configuring from stock and delivered quickly. Delivery was built around selected by parameter set, accuracy and field portability, with point-by-point checks on: food-safety and hygienic design per 3-A / EHEDG.

Operating Outcome

In service the system performs as intended — results available on site, reducing lab re-checks, with routine maintenance falling noticeably.

Chemical & Pharmaceutical

Chemical & Pharmaceutical · Hanna — Stock Configuration Case

Application Context

reactors, metering vessels and finished-product tanks is a typical Chemical & Pharmaceutical duty. The project started from Hanna, focusing on covering portable and laboratory water testing with Hanna instruments.

Process Constraints

corrosion plus Ex protection shortens instrument life and makes downtime costly, and highly corrosive media with solvents and crystallisation, partly in explosive atmospheres only amplify it. The Hanna specification must therefore cover selected by parameter set, accuracy and field portability.

Delivery Approach

Delivery was handled as the stock channel — configuring from stock and delivered quickly. Execution centred on selected by parameter set, accuracy and field portability, together with Ex certification and GMP traceability of records.

Field Results

Operation shows the benefit clearly — results available on site, reducing lab re-checks, with confidence in this measuring point improving markedly.

Power & Energy

Power & Energy · Hanna — Stock Configuration Case

Customer Profile

The typical setting in Power & Energy is boiler feedwater, turbine condensate and FGD/DeNOx systems. The measuring point is Hanna; the focus is covering portable and laboratory water testing with Hanna instruments.

Key Difficulties

Conditions are high temperature and pressure with both steam and saline water and, on top of that, drift under high temperature and pressure, with very costly unplanned outages, which a standard configuration cannot handle for long. The design therefore starts with selected by parameter set, accuracy and field portability.

Implementation

The scope ran through the stock channel: configuring from stock and delivered quickly. Technically it hinges on selected by parameter set, accuracy and field portability, and on these requirements: compliance with power-industry codes and unit availability targets.

Customer Benefit

In practice this means results available on site, reducing lab re-checks, which cut the workload on the site maintenance team.