SEKO Saego
Komba Serieselectromagnetic diaphragm metering pump
Komba series is a microprocessor-controlled digital display electromagnetic diaphragm metering pump with simple and stable operation. Includes 4 sub-families: DMS,DML,DMC and DMM.
main features:
- maximum flow: 9 L/H, maximum pressure: 10 Bar
compatibility:
- PVDF pump head and ceramic ball valve as the standard configuration of the pump
- PVDF pump head is compatible with all chemicals used in industry, sewage treatment and drinking water; the use of ceramic ball valves improves the reliability of dosing and the chemical compatibility of the entire liquid contact end.
reliable performance:
- After inspection, the service life of the diaphragm exceeds 5 years. Advanced design concept and excellent manufacturing process, resulting in the long service life of the diaphragm diaphragm is made of pure solid PTFE material, can be compatible with most chemicals.
dosing mode:
- flow can be adjusted manually or automatically (signal input control). DML,DMM and DMC also have a liquid level probe interface and manual exhaust valve, which can assist in starting the pump.
touch liquid end material:
- pump head: PVDF
- valve ball: Ceramic
- sealing: FPM/EPDM
- diaphragm: PTFE
Installation method:
- Horizontal installation
| Komba Series | |||||||||
![]() |
DMS: Flow Manual Adjustment Manually adjust the flow through the buttons on the control panel, the pump runs or stops, and the LED indicator can display the frequency percentage and the number of strokes |
||||||||
|
|
DML: manual flow adjustment, with liquid level probe interface Manually adjust the flow through the buttons on the control panel, the pump runs or stops, and the LED indicator can display the frequency percentage and the number of strokes |
||||||||
|
|
DMC: automatic adjustment (real-time pulse signal control), with liquid level probe interface, with operating status display can choose the following two different dosing machine types: flow manual adjustment mode: metering pump dosing according to the manually selected frequency/percentage flow automatic adjustment mode: metering pump dosing according to the received input signal "digital pulse signal) |
||||||||
|
|
DMM: automatic adjustment (4-20mA current signal control), with liquid level probe interface, with operating status display can choose the following two different dosage horizontal modes: flow manual adjustment mode: metering pump will automatically adjust the flow according to the frequency/percentage manually selected: metering pump will proportionally dose according to the received input signal "4-20mA current signal) |
||||||||
Model Code:
| Series | ||||||||||
| DMS | Flow Manual Adjustment | |||||||||
| DML | quantity with liquid level probe interface | |||||||||
| DMC | Manual flow adjustment/flow ratio adjustment: external digital pulse signal to adjust the flow ratio (for example, pulse signal from water meter), with liquid level probe port | |||||||||
| DMM | Manual flow adjustment/flow ratio adjustment: external analog signal (0/4-20 mA) or digital pulse signal to adjust the flow ratio (for example, pulse signal from water meter), with liquid level probe interface | |||||||||
| Model | pressure (bar) | flow (L/H) | stroke flow (ml/stroke) |
Connecting pipe size Inner diameter/outer diameter (mm) |
maximum frequency (stroke/minute) |
power (W) | weight (KG) | carton size Length X Width X Height (mm) |
||
| 200 | 10 | 3 | 0.31 | 4/6 | 160 | 14 | 2.8 | 290X215X195 | ||
| 8 | 5 | 0.52 | ||||||||
| 2 | 9 | 0.93 | ||||||||
| 201 | 7 | 1 | 0.10 | |||||||
| power supply | ||||||||||
| A |
240Vac,50Hz (DMS only) |
|||||||||
| N | 100-240Vac,50/60Hz | |||||||||
| Material of touch end | pump head | valve ball | diaphragm | |||||||
| H | PVDF | ceramic | PTFE | |||||||
| Installation accessories | ||||||||||
| P | PVDF | |||||||||
| sealing ring | ||||||||||
| 0 | FPM | |||||||||
| 1 | EPDM | |||||||||
| color | Rear | Front | ||||||||
| 8 | standard | RAL7004 | RAL5010 | |||||||
| Signal Interface | ||||||||||
| 0 | standard | |||||||||
| customization | ||||||||||
| 0 | standard | |||||||||
| DML | 200 | N | H | P | 0 | 8 | 0 | 0 | ||