KOMBA Series SEKO SAIGO Electromagnetic Diaphragm Metering Pump

KOMBA Series SEKO SAIGO Electromagnetic Diaphragm Metering Pump

SEKO solenoid diaphragm dosing pump

SEKO KOMBA
Configurable Models 16 models
The KomBa series is a microprocessor-controlled digital solenoid diaphragm metering pump featuring simple operation and stable running. It includes 4 sub-series: DMS, DML, DMC and DMM.

SEKO Saego

Komba Serieselectromagnetic diaphragm metering pump

Komba series is a microprocessor-controlled digital display electromagnetic diaphragm metering pump with simple and stable operation. Includes 4 sub-families: DMS,DML,DMC and DMM.

main features:

  • maximum flow: 9 L/H, maximum pressure: 10 Bar

compatibility:

  • PVDF pump head and ceramic ball valve as the standard configuration of the pump
  • PVDF pump head is compatible with all chemicals used in industry, sewage treatment and drinking water; the use of ceramic ball valves improves the reliability of dosing and the chemical compatibility of the entire liquid contact end.

reliable performance:

  • After inspection, the service life of the diaphragm exceeds 5 years. Advanced design concept and excellent manufacturing process, resulting in the long service life of the diaphragm diaphragm is made of pure solid PTFE material, can be compatible with most chemicals.

dosing mode:

  • flow can be adjusted manually or automatically (signal input control). DML,DMM and DMC also have a liquid level probe interface and manual exhaust valve, which can assist in starting the pump.

touch liquid end material:

  • pump head: PVDF
  • valve ball: Ceramic
  • sealing: FPM/EPDM
  • diaphragm: PTFE

Installation method:

  • Horizontal installation
Komba Series
DMS: Flow Manual Adjustment
Manually adjust the flow through the buttons on the control panel, the pump runs or stops, and the LED indicator can display the frequency percentage and the number of strokes

DML: manual flow adjustment, with liquid level probe interface
Manually adjust the flow through the buttons on the control panel, the pump runs or stops, and the LED indicator can display the frequency percentage and the number of strokes

DMC: automatic adjustment (real-time pulse signal control), with liquid level probe interface, with operating status display
can choose the following two different dosing machine types: flow manual adjustment mode: metering pump dosing according to the manually selected frequency/percentage flow automatic adjustment mode: metering pump dosing according to the received input signal "digital pulse signal)

DMM: automatic adjustment (4-20mA current signal control), with liquid level probe interface, with operating status display
can choose the following two different dosage horizontal modes: flow manual adjustment mode: metering pump will automatically adjust the flow according to the frequency/percentage manually selected: metering pump will proportionally dose according to the received input signal "4-20mA current signal)

Model Code:

Series
DMS Flow Manual Adjustment
DML quantity with liquid level probe interface
DMC Manual flow adjustment/flow ratio adjustment: external digital pulse signal to adjust the flow ratio (for example, pulse signal from water meter), with liquid level probe port
DMM Manual flow adjustment/flow ratio adjustment: external analog signal (0/4-20 mA) or digital pulse signal to adjust the flow ratio (for example, pulse signal from water meter), with liquid level probe interface
Model pressure (bar) flow (L/H) stroke flow
(ml/stroke)
Connecting pipe size
Inner diameter/outer diameter (mm)
maximum frequency
(stroke/minute)
power (W) weight (KG) carton size
Length X Width X Height (mm)
200 10 3 0.31 4/6 160 14 2.8 290X215X195
8 5 0.52
2 9 0.93
201 7 1 0.10
power supply
A

240Vac,50Hz

(DMS only)

N 100-240Vac,50/60Hz
Material of touch end pump head valve ball diaphragm
H PVDF ceramic PTFE
Installation accessories
P PVDF
sealing ring
0 FPM
1 EPDM
color Rear Front
8 standard RAL7004 RAL5010
Signal Interface
0 standard
customization
0 standard
DML 200 N H P 0 8 0 0
16 models · click to collapse
Municipal Wastewater Treatment

Municipal Wastewater Treatment · KOMBA — Application Case

Application Context

the inlet, biological and outlet stages of a municipal plant is a typical Municipal Wastewater Treatment duty. The project started from KOMBA, focusing on compact solenoid diaphragm dosing with the KOMBA range.

Process Constraints

effluent parameters drift and probes foul with sludge and biofilm, and high solids and corrosive fractions, with large diurnal flow swings only amplify it. The KOMBA specification must therefore cover sized by installation space, dosing rate and level-signal interface.

Delivery Approach

Delivery was handled as the solenoid diaphragm series — selecting for solenoid-driven diaphragm dosing behaviour. Execution centred on sized by installation space, dosing rate and level-signal interface, together with stable compliance with Grade 1A discharge limits and online data reporting.

Field Results

Operation shows the benefit clearly — small footprint, easy to add in retrofit projects, with confidence in this measuring point improving markedly.

Food & Beverage

Food & Beverage · KOMBA — Application Case

Customer Profile

The typical setting in Food & Beverage is dosing, pasteurising, filling and CIP stages. The measuring point is KOMBA; the focus is compact solenoid diaphragm dosing with the KOMBA range.

Key Difficulties

Conditions are syrups, dairy and beverages that scale easily, under strict hygienic requirements and, on top of that, frequent cleaning demands instruments that withstand hot CIP/SIP caustic cycles, which a standard configuration cannot handle for long. The design therefore starts with sized by installation space, dosing rate and level-signal interface.

Implementation

The scope ran through the solenoid diaphragm series: selecting for solenoid-driven diaphragm dosing behaviour. Technically it hinges on sized by installation space, dosing rate and level-signal interface, and on these requirements: food-safety and hygienic design per 3-A / EHEDG.

Customer Benefit

In practice this means small footprint, easy to add in retrofit projects, which cut the workload on the site maintenance team.

Chemical & Pharmaceutical

Chemical & Pharmaceutical · KOMBA — Application Case

Project Background

The project covers reactors, metering vessels and finished-product tanks. The work centres on KOMBA and the core task is compact solenoid diaphragm dosing with the KOMBA range.

Operating Challenges

The medium and duty are characterised by highly corrosive media with solvents and crystallisation, partly in explosive atmospheres, and corrosion plus Ex protection shortens instrument life and makes downtime costly. So KOMBA cannot be specified generically — it calls for sized by installation space, dosing rate and level-signal interface.

Solution

The Ainstru engineering team worked through the solenoid diaphragm series: selecting for solenoid-driven diaphragm dosing behaviour. The configuration involves sized by installation space, dosing rate and level-signal interface, with these requirements in view: Ex certification and GMP traceability of records.

Results

Since start-up the system has run steadily; the practical result is small footprint, easy to add in retrofit projects.

Power & Energy

Power & Energy · KOMBA — Application Case

Project Overview

The site is boiler feedwater, turbine condensate and FGD/DeNOx systems. The customer wanted KOMBA properly configured on the existing plant, with the aim of compact solenoid diaphragm dosing with the KOMBA range.

Technical Challenges

What actually causes trouble is high temperature and pressure with both steam and saline water, and drift under high temperature and pressure, with very costly unplanned outages. All of this means the KOMBA configuration has to involve sized by installation space, dosing rate and level-signal interface.

Configuration

Supply and installation were organised through the solenoid diaphragm series: selecting for solenoid-driven diaphragm dosing behaviour. On site this meant sized by installation space, dosing rate and level-signal interface, checked line by line against: compliance with power-industry codes and unit availability targets.

Performance

After commissioning the outcome is small footprint, easy to add in retrofit projects, and the readings are now used for process tuning.