MCS100FT is at the forefront with proven technology, everything under control
Advantages
-
Real-time HF limit monitoring
-
More than 12 measuring components with just one analyzer
-
Easily integrated into the customer's network environment
-
Maintenance intervals of many measuring components can be as long as 6 months
-
Verified for measuring greenhouse gases such as N2O, CH4 and CO2
-
Lower maintenance costs
Application
The FTIR measuring principle enables simultaneous detection of more than 12 measuring components - tailored to each customer's requirements. The FTIR analysis system MCS100FT, with its heated measuring cell made of corrosion-resistant materials, meets legislative requirements for monitoring hydrogen fluoride limits. The MCS100FT features an oxygen sensor as standard and can be supplemented with a total hydrocarbon analyzer. With its reliable measuring technology, simple operation and low maintenance costs, the MCS100FT provides a leading solution.
-
Emission monitoring in waste incineration plants
-
Real-time HF limit monitoring, e.g. in aluminum production processes
-
Gas emission monitoring in cement kilns and power plants
Overview:
-
Certified lowest HF range: 0 ... 3 mg/m³
-
Automatic spectrum adjustment AutoVAL for reliable measured values
-
With EN15267 certification
-
Remote control and diagnostics via SOPAS ET software
-
Automatic analyzer adjustment
-
Fully automatic backflushing and filter cleaning of the sampling unit
Source:Endress+Hauserpublicly available information
Case Studies
Municipal Wastewater Treatment · Gas Analysis — Application Case
Project Overview
The site is the inlet, biological and outlet stages of a municipal plant. The customer wanted Gas Analysis properly configured on the existing plant, with the aim of continuous analysis of target components in flue or process gas.
Technical Challenges
What actually causes trouble is high solids and corrosive fractions, with large diurnal flow swings, and effluent parameters drift and probes foul with sludge and biofilm. All of this means the Gas Analysis configuration has to involve choosing the analysis principle by range, background gas and conditioning.
Configuration
Supply and installation were organised through the analyser range: selecting as part of a complete water-analysis system. On site this meant choosing the analysis principle by range, background gas and conditioning, checked line by line against: stable compliance with Grade 1A discharge limits and online data reporting.
Performance
After commissioning the outcome is optimised combustion, cutting both fuel use and emissions, and the readings are now used for process tuning.
Food & Beverage · Gas Analysis — Application Case
Site Conditions
This is a Food & Beverage customer whose plant is at dosing, pasteurising, filling and CIP stages. The main task was continuous analysis of target components in flue or process gas.
The Problem
The difficulty lies in syrups, dairy and beverages that scale easily, under strict hygienic requirements; at the same time frequent cleaning demands instruments that withstand hot CIP/SIP caustic cycles. Specification therefore means choosing the analysis principle by range, background gas and conditioning.
What We Did
We took a analyser range approach — selecting as part of a complete water-analysis system. Delivery was built around choosing the analysis principle by range, background gas and conditioning, with point-by-point checks on: food-safety and hygienic design per 3-A / EHEDG.
Operating Outcome
In service the system performs as intended — optimised combustion, cutting both fuel use and emissions, with routine maintenance falling noticeably.
Chemical & Pharmaceutical · Gas Analysis — Application Case
Application Context
reactors, metering vessels and finished-product tanks is a typical Chemical & Pharmaceutical duty. The project started from Gas Analysis, focusing on continuous analysis of target components in flue or process gas.
Process Constraints
corrosion plus Ex protection shortens instrument life and makes downtime costly, and highly corrosive media with solvents and crystallisation, partly in explosive atmospheres only amplify it. The Gas Analysis specification must therefore cover choosing the analysis principle by range, background gas and conditioning.
Delivery Approach
Delivery was handled as the analyser range — selecting as part of a complete water-analysis system. Execution centred on choosing the analysis principle by range, background gas and conditioning, together with Ex certification and GMP traceability of records.
Field Results
Operation shows the benefit clearly — optimised combustion, cutting both fuel use and emissions, with confidence in this measuring point improving markedly.
Power & Energy · Gas Analysis — Application Case
Customer Profile
The typical setting in Power & Energy is boiler feedwater, turbine condensate and FGD/DeNOx systems. The measuring point is Gas Analysis; the focus is continuous analysis of target components in flue or process gas.
Key Difficulties
Conditions are high temperature and pressure with both steam and saline water and, on top of that, drift under high temperature and pressure, with very costly unplanned outages, which a standard configuration cannot handle for long. The design therefore starts with choosing the analysis principle by range, background gas and conditioning.
Implementation
The scope ran through the analyser range: selecting as part of a complete water-analysis system. Technically it hinges on choosing the analysis principle by range, background gas and conditioning, and on these requirements: compliance with power-industry codes and unit availability targets.
Customer Benefit
In practice this means optimised combustion, cutting both fuel use and emissions, which cut the workload on the site maintenance team.