FX86 Guided radar level transmitter

FX86 Guided radar level transmitter
Guided radar level transmitter
VEGA FX86
Configurable Models 20 models
Guided wave radar level transmitter for continuous level and interface measurement, for demanding conditions
Compare

Measurement

Measuring range ƲƲ Coaxial measuring probe up to 6 m (19.69 ft)
Accuracy ± 2 mm

Process conditions

Process fitting Thread from G1½, 1½ NPT, flange from 50, 2"
Process pressure -1 … +400 bar/-100 … +40000 kPa (-14.5 … +5800 psig)
Process temperature -196 … +450 ℃ (-320 … +842 ℉)
Ambient, storage and transport temperature -40 … +80 ℃ (-40 … +176 ℉)

Electrical & communication

Operating voltage 8 … 30 V DC

Application area

With VEGAFLEX 86 you can measure virtually all kinds of bulk solidsand liquids, also under extreme pressure and temperature conditionsessentially maintenance free. The sensor delivers precise and reliablemeasured values even in applications with buildup, foam generation orcondensation. In saturated steam applications, the special referenceprobe ensures a density-independent measurement. VEGAFLEX 86 isa truly cost-effective level and interface sensor for your measuring task.

Your benefit

  • The guided adjustment enables a simple, time-saving and reliable
  • setup
  • Comprehensive diagnosis options allow maintenance-free operation
  • and thus high plant availability
  • Shortenable probes allow simple standardization and maximum flex­
  • ibility in planning

Function

High frequency microwave pulses are coupled onto a cable or rod andguided along the probe. The pulse is reflected by the product surface.The time from emission to reception of the signals is proportional to thelevel in the vessel.

43 models · click to collapse
Municipal Wastewater Treatment

Municipal Wastewater Treatment · guided wave radar — Application Case

Project Background

The project covers the inlet, biological and outlet stages of a municipal plant. The work centres on guided wave radar and the core task is level and interface measurement along a guided probe or cable.

Operating Challenges

The medium and duty are characterised by high solids and corrosive fractions, with large diurnal flow swings, and effluent parameters drift and probes foul with sludge and biofilm. So guided wave radar cannot be specified generically — it calls for choosing rod or cable by dielectric constant, range and agitation.

Solution

The Ainstru engineering team worked through the level range: level solution matched to the actual tank and silo geometry. The configuration involves choosing rod or cable by dielectric constant, range and agitation, with these requirements in view: stable compliance with Grade 1A discharge limits and online data reporting.

Results

Since start-up the system has run steadily; the practical result is works even with low-dielectric media, with a small dead zone and high accuracy.

Food & Beverage

Food & Beverage · guided wave radar — Application Case

Project Overview

The site is dosing, pasteurising, filling and CIP stages. The customer wanted guided wave radar properly configured on the existing plant, with the aim of level and interface measurement along a guided probe or cable.

Technical Challenges

What actually causes trouble is syrups, dairy and beverages that scale easily, under strict hygienic requirements, and frequent cleaning demands instruments that withstand hot CIP/SIP caustic cycles. All of this means the guided wave radar configuration has to involve choosing rod or cable by dielectric constant, range and agitation.

Configuration

Supply and installation were organised through the level range: level solution matched to the actual tank and silo geometry. On site this meant choosing rod or cable by dielectric constant, range and agitation, checked line by line against: food-safety and hygienic design per 3-A / EHEDG.

Performance

After commissioning the outcome is works even with low-dielectric media, with a small dead zone and high accuracy, and the readings are now used for process tuning.

Chemical & Pharmaceutical

Chemical & Pharmaceutical · guided wave radar — Application Case

Site Conditions

This is a Chemical & Pharmaceutical customer whose plant is at reactors, metering vessels and finished-product tanks. The main task was level and interface measurement along a guided probe or cable.

The Problem

The difficulty lies in highly corrosive media with solvents and crystallisation, partly in explosive atmospheres; at the same time corrosion plus Ex protection shortens instrument life and makes downtime costly. Specification therefore means choosing rod or cable by dielectric constant, range and agitation.

What We Did

We took a level range approach — level solution matched to the actual tank and silo geometry. Delivery was built around choosing rod or cable by dielectric constant, range and agitation, with point-by-point checks on: Ex certification and GMP traceability of records.

Operating Outcome

In service the system performs as intended — works even with low-dielectric media, with a small dead zone and high accuracy, with routine maintenance falling noticeably.

Power & Energy

Power & Energy · guided wave radar — Application Case

Application Context

boiler feedwater, turbine condensate and FGD/DeNOx systems is a typical Power & Energy duty. The project started from guided wave radar , focusing on level and interface measurement along a guided probe or cable.

Process Constraints

drift under high temperature and pressure, with very costly unplanned outages, and high temperature and pressure with both steam and saline water only amplify it. The guided wave radar specification must therefore cover choosing rod or cable by dielectric constant, range and agitation.

Delivery Approach

Delivery was handled as the level range — level solution matched to the actual tank and silo geometry. Execution centred on choosing rod or cable by dielectric constant, range and agitation, together with compliance with power-industry codes and unit availability targets.

Field Results

Operation shows the benefit clearly — works even with low-dielectric media, with a small dead zone and high accuracy, with confidence in this measuring point improving markedly.