Order Code:SWING63.CAFEDXVN
Name:SWING63.CAFEDXVN
Configuration
| Code | Name | Order | Specification |
|---|---|---|---|
| 030 | Approval | CA | II 1G, 1/2G, 2G Ex ia IIC T6...T1 Ga, Ga/Gb, Gb + Overfill protection (WHG, KVU, VLAREM) |
| 040 | Process fitting / Material | FED | Flange DN50 PN40 Form B1, EN1092-1 / PFA |
| 050 | Adapter / Process temperature | X | without / -50...+150°C |
| 060 | Housing / Protection / Cable gland | V | Stainless steel single chamber (precision casting) / IP66/IP67 / M20x1.5 |
| 090 | Electronics | N | NAMUR signal |
Configuration Explained
This is a SWING63 vibrating level switch, with ATEX intrinsic safety approval and WHG overflow protection, usable in hazardous areas with compliant overflow prevention, DN50 PN40 Form B1 flange process connection, according to EN1092-1, PFA material, it withstands highly corrosive media, resistant to -50 to 150 °C, stainless steel single-chamber precision cast housing IP66/67, M20 entry, NAMUR signal electronics, suitable for hazardous area highly corrosive tanks.
Related Products
Endress+HauserLiquiphant FTL31
Endress+HauserSoliphant M FTM50
Endress+HauserDensity controller FML621 for Liquiphant
Endress+HauserLiquiphant FTL41
Endress+HauserTuning fork level switch
Endress+HauserSoliphant M FTM51
Endress+HauserSoliphant T FTM20
Endress+Hauser