Home    analyzer    sterilize    CCM223 residual chlorine transmitter
  • Liquisys CCM223 is a standard residual chlorine measuring transmitter and can measure pH to compensate for residual chlorine measurements. With rational design, measurement process and sensor self-test, it can improve operational safety. No matter how to choose from a large number of hardware and software modules, such as relays and bus communication, it can be fully adapted to the measurement task. It also allows the transmitter to be upgraded at any time, and its simple menu and factory calibration make configuration and operation easy and quick.

     

    advantage

    greater operational safety: continuous process check system, customized alarm settings, calibration plausibility check

    Reliable chlorine and pH control: current input for flow monitoring with controller shutdown or for feed-forward control

    Easy operation and service: Intuitive user interface, simple chlorine and pH calibration, manual contact control

    Reduce maintenance workload: automatic cleaning function triggered by alarm and limit switch (with Chemoclean)

    Suitable for various applications: Multiple expansion forms, such as P(ID) controllers, timers, etc., suitable for all processes

     

    Application areas

    Liquisys CCM223 transmitters can be used with analog total chlorine, residual chlorine, chlorine dioxide and pH electrodes for the following industries:

     

    Water & Sewage

    -Sterilization process control and monitoring

    -Desalination using membrane technology

    -Swimming Pool

    -gas scrubber

    Food & Beverage

    -Disinfection of process water

    power plant

    -cooling water disinfection

    Liquisys CCM223 uses the following communication protocols and interfaces:

     

    0/4...20mA

    HART

    PROFIBUS DP

    PROFIBUS PA

     

    E H Product Model Configuration Tool

    Please enter the product model to configure

    product comparison

    Please enter the product model to be compared in the input box below. Up to three product comparisons are supported.

     

     

    Technical Information

     

    technical parameters

     

    Documentation/Manuals/Software

     

    Accessories/Spare Parts

    Source:Endress Hauserwebsite public information

CCM223 residual chlorine transmitter

E+H residual chlorine, chlorine dioxide, total chlorine transmitters, commonly used models: CCM223-EK0005 is connected to analog electrodes CCS51/CCS50/CCS120, single input, without PH compensation. CCM223-EP0005 is connected to analog electrodes CCS51/CCS50/CCS120+PH/ORP electrodes such as CPS11/CPS31/CPS12, with two inputs and pH compensation.
CCM223 residual chlorine transmitter

everyone is watching: